7. RECOMMENDED SETUP cont.

Cleaning

Use a moist cloth to wipe down the pump housing. Allow to dry 

thoroughly before storing in a dry location that is protected from bad 

weather conditions.

Storage

If there is danger of frost, dismantle the device and accessories, clean 

and store them in a place protected from frost.

Dismantle and store

1.   Disconnect the device from the 

mains supply.

2.   Fully open any shut-off 

mechanisms (spray nozzles, 

valves, etc.) in the pressure 

line so that the air can escape 

without obstruction.

Note:

 Ensure the gate valve on your 

water tank is not left open as this will 

allow water to drain from the tank.

3.   Completely empty the pump by 

unscrewing the water drain plug.

4.   Dismantle the suction and pressure lines from the device.

5.   Store device in a frost-free room  

(at least 5 °C).

WARNING! 

MAKE SURE THE PUMP IS DISCONNECTED 

FROM ELECTRIC POWER SUPPLY BEFORE 

PERFORMING MAINTENANCE PROCEDURES.

WARNING! 

MAKE SURE THAT THE DEVICE AND 

CONNECTED ACCESSORIES ARE DEPRESSURIZED 

BEFORE CARRYING OUT ANY WORK ON THE DEVICE.

MAINTENANCE

CONNECTION WITH TANK BASE BELOW WATER PUMP

P

CONNECTION WITH TANK BASE ABOVE THE WATER PUMP

 

 

CONNECTION WITH TANK BASE LEVEL WITH WATER PUMP

FIRM BASE

SOLID STRUCTURE

WATERTANK

WATERTANK

NON-RETURN

VALVE

DISCHARGE

OUTLET

GATE 

VALVE

GATE 

VALVE

SUCTION LINE

SUCTION LINE

150mm

150mm

150mm

150mm

150mm

FIRM BASE

SOLID STRUCTURE

DISCHARGE

OUTLET

150mm

UNION 

COUPLING

depending on 

installation

UNION 

COUPLING

depending on 

installation

 

WATERTANK

GATE 

VALVE

SUCTION LINE

SOLID STRUCTURE

DISCHARGE

OUTLET

FIRM BASE

UNION 

COUPLING

depending on 

installation

IN-LINE

FILTER

IN-LINE

FILTER

IN-LINE

FILTER

Summary of Contents for CPPAS-800

Page 1: ...erform maintenance as set out within the instruction manual If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANTY TO ENSURE A SPEEDY RESPONSE P...

Page 2: ...ently capable of supporting the total weight of the device when filled with water Four mounting recesses allow for fixing the base to the mounting surface bolts not supplied Note The installation site...

Page 3: ...on inlet 1 Teflon tape is required on threads to ensure a water tight seal and prevent any leakage Wind Teflon clockwise on fittings 2 Remove the plastic protection cover from the suction inlet 3 Inse...

Page 4: ...ON DO NOT USE IT FOR CORROSIVE ABRASIVE EXPLOSIVE OR DANGEROUS LIQUIDS CAUTION THE PUMP SHOULD BE FILLED WITH WATER AFTER EACH NEW CONNECTION OR IF WATER LOSS OR AIR INTAKE HAS OCCURRED EXTENDED OPERA...

Page 5: ...line should be as short as possible since the conveying capacity decreases as the length of the line increases Note A leaking hose or pipe will draw in air and therefore not draw in any water Note A...

Page 6: ...ow water to drain from the tank 3 Completely empty the pump by unscrewing the water drain plug 4 Dismantle the suction and pressure lines from the device 5 Store device in a frost free room at least 5...

Page 7: ...water The pump won t start Power not switched on If the green light doesn t illuminate check the mains supply Restart button has not been pressed When the pump requires restating Failure light illumi...

Page 8: ...b Do not operate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes c Keep children and bysta...

Reviews: