background image

Pump Control Unit

‘GREEN Power on’.

This indicates that there is power to the 

pump, but the pump is currently not on.

‘ GREEN Pump on’.

This indicates that there is power to the 

pump and the pump is running.

‘RED F GREEN’.

There is power to the pump, but flow is 

stalled. In this event, press the Restart 

button.
If the malfunction still occours, refer to the 

TROUBLESHOOTING”

 section to find a 

remedy.

‘RESTART Button’.

When the pump requires restating (Failure 

light illuminates red), push the Restart 

button and hold for 5 seconds to re-start 

the pump, the red failure light should 

turn off.  If the failure light re-illuminates 

red, refer to the “

TROUBLESHOOTING” 

section to find a remedy.

Note:

 

If all three lights are on; the Pump has detected a failure, but will 

continue to run for approx. 10 seconds to attempt to fix the problem. 

CPPAS-800

6. OPERATING THE PUMP

7. RECOMMENDED SETUP

WARNING! 

THE INPUT HOSE OR PIPE SHOULD BE 

LOW ENOUGH IN THE WATER TO ENSURE THAT IF 

THE WATER LEVEL FALLS, THE PUMP WILL NOT RUN DRY. 

ENSURE THAT THIS IS CHECKED WHEN IN OPERATION.

Positioning the hose or pipe

Position the input hose or pipe so that it rises from the water drawing 

source to the pump. Where possible, avoid positioning the input hose 

or pipe higher than the pump, as this would delay the escape of air 

bubbles from the input hose or pipe and impede the priming process 

(see section ‘

Priming the pump

’ for description on priming the pump)

•   The suction line should be as short as possible, since the conveying 

capacity decreases as the length of the line increases.

Note:

 A leaking hose or pipe will draw in air and therefore not draw in 

any water. 

Note:

 A non-return valve is recommended so that the water does not 

run off when the pump is shut off.

Note:

 A suction in-line filter with a 3000l/hour min flow rate, and 150 to 

250 micron mesh must be used to protect the pump from sand, dirt etc. 

The Ozito PAPF-001 Pre-filter or equivalent is available from Bunnings 

stores.

Note: 

During the initial set-up, please purge all air from the system via 

the discharge outlet highest in the system. 

Recommended set-up

CONNECTION WITH TANK BASE BELOW WATER PUMP

P

CONNECTION WITH TANK BASE ABOVE THE WATER PUMP

 

 

CONNECTION WITH TANK BASE LEVEL WITH WATER PUMP

FIRM BASE

SOLID STRUCTURE

WATERTANK

WATERTANK

NON-RETURN

VALVE

DISCHARGE

OUTLET

GATE 

VALVE

GATE 

VALVE

SUCTION LINE

SUCTION LINE

150mm

150mm

150mm

150mm

150mm

FIRM BASE

SOLID STRUCTURE

DISCHARGE

OUTLET

150mm

UNION 

COUPLING

depending on 

installation

UNION 

COUPLING

depending on 

installation

 

WATERTANK

GATE 

VALVE

SUCTION LINE

SOLID STRUCTURE

DISCHARGE

OUTLET

FIRM BASE

UNION 

COUPLING

depending on 

installation

IN-LINE

FILTER

IN-LINE

FILTER

IN-LINE

FILTER

CONNECTION WITH TANK BASE BELOW WATER PUMP

P

CONNECTION WITH TANK BASE ABOVE THE WATER PUMP

 

 

CONNECTION WITH TANK BASE LEVEL WITH WATER PUMP

FIRM BASE

SOLID STRUCTURE

WATERTANK

WATERTANK

NON-RETURN

VALVE

DISCHARGE

OUTLET

GATE 

VALVE

GATE 

VALVE

SUCTION LINE

SUCTION LINE

150mm

150mm

150mm

150mm

150mm

FIRM BASE

SOLID STRUCTURE

DISCHARGE

OUTLET

150mm

UNION 

COUPLING

depending on 

installation

UNION 

COUPLING

depending on 

installation

 

WATERTANK

GATE 

VALVE

SUCTION LINE

SOLID STRUCTURE

DISCHARGE

OUTLET

FIRM BASE

UNION 

COUPLING

depending on 

installation

IN-LINE

FILTER

IN-LINE

FILTER

IN-LINE

FILTER

WARNING! 

TO ENSURE CORRECT PUMP OPERATION 

IT IS ESSENTIAL THAT A SUCTION IN-LINE FILTER BE 

USED FOR A CLEAN WATER SUPPLY.

INSTALLATION

Summary of Contents for CPPAS-800

Page 1: ...erform maintenance as set out within the instruction manual If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANTY TO ENSURE A SPEEDY RESPONSE P...

Page 2: ...ently capable of supporting the total weight of the device when filled with water Four mounting recesses allow for fixing the base to the mounting surface bolts not supplied Note The installation site...

Page 3: ...on inlet 1 Teflon tape is required on threads to ensure a water tight seal and prevent any leakage Wind Teflon clockwise on fittings 2 Remove the plastic protection cover from the suction inlet 3 Inse...

Page 4: ...ON DO NOT USE IT FOR CORROSIVE ABRASIVE EXPLOSIVE OR DANGEROUS LIQUIDS CAUTION THE PUMP SHOULD BE FILLED WITH WATER AFTER EACH NEW CONNECTION OR IF WATER LOSS OR AIR INTAKE HAS OCCURRED EXTENDED OPERA...

Page 5: ...line should be as short as possible since the conveying capacity decreases as the length of the line increases Note A leaking hose or pipe will draw in air and therefore not draw in any water Note A...

Page 6: ...ow water to drain from the tank 3 Completely empty the pump by unscrewing the water drain plug 4 Dismantle the suction and pressure lines from the device 5 Store device in a frost free room at least 5...

Page 7: ...water The pump won t start Power not switched on If the green light doesn t illuminate check the mains supply Restart button has not been pressed When the pump requires restating Failure light illumi...

Page 8: ...b Do not operate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes c Keep children and bysta...

Reviews: