ACP-24151
3. TROUBLE SHOOTING
Problem
Cause
Solution
The compressor
does not start
No power supply
Check the power
supply, the power
plug and the socket-
outlet
Outside temperature is
too low
Never operate
with an outside
temperature of
below 5°C
Motor is overheated
Allow the motor
to cool down. If
necessary, remedy
the cause of the
overheating
The compressor
starts but there
is no pressure
Leak in the quick
connect
Replace the quick
connect
Regulating knob set
too low
Adjust the
regulating knob to a
higher pressure
The drain plug leaks
Tighten the lever
by hand. Check the
seal and replace if
necessary
The compressor
starts, pressure
is shown on the
pressure gauge,
but no pressure to
the air tool.
Loose hose
connections
Check the
compressed air
hose and tools and
replace if necessary
Leak in a quick-lock
coupling
Check the quick-
lock coupling and
replace if necessary
Insufficient pressure
set on the pressure
regulator
Open the pressure
regulator further
WARNING!
DO NOT ATTEMPT TO ADJUST/MODIFY
THE SAFETY VALVE IN ANY WAY. THE SAFETY VALVE
INSTALLED ON THIS AIR COMPRESSOR IS DESIGNED
TO AUTOMATICALLY RELEASE PRESSURE IN CASE
OF EXCESS PRESSURE BUILD UP IN THE TANK.