background image

ACP-24151

3. TROUBLE SHOOTING

Problem

Cause

Solution

The compressor  

does not start

No power supply

Check the power 

supply, the power 

plug and the socket-

outlet

Outside temperature is 

too low

Never operate 

with an outside 

temperature of 

below 5°C

Motor is overheated

Allow the motor 

to cool down. If 

necessary, remedy 

the cause of the 

overheating

The compressor 

starts but there  

is no pressure

 Leak in the quick 

connect

Replace the quick 

connect

Regulating knob set 

too low

Adjust the 

regulating knob to a 

higher pressure

The drain plug leaks

Tighten the lever 

by hand. Check the 

seal and replace if 

necessary

The compressor 

starts, pressure 

is shown on the 

pressure gauge,  

but no pressure to 

the air tool.

Loose hose 

connections

Check the 

compressed air 

hose and tools and 

replace if necessary

Leak in a quick-lock 

coupling

Check the quick-

lock coupling and 

replace if necessary

Insufficient pressure 

set on the pressure 

regulator

Open the pressure 

regulator further

WARNING!

 

DO NOT ATTEMPT TO ADJUST/MODIFY 

THE SAFETY VALVE IN ANY WAY. THE SAFETY VALVE 

INSTALLED ON THIS AIR COMPRESSOR IS DESIGNED 

TO AUTOMATICALLY RELEASE PRESSURE IN CASE 

OF EXCESS PRESSURE BUILD UP IN THE TANK.

Summary of Contents for ACP-24151

Page 1: ...ustrial or high frequency use WARRANTY TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL NUMBER AND DATE OF PURCHASE AVAILABLE A CUSTOMER SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND ANSWER ANY QUES...

Page 2: ...ged do not use contact Ozito The compressor should be set up near the area of use Avoid long air lines and long supply lines extensions Make sure the intake air is dry and dust free Do not set up the...

Page 3: ...lug from the air intake hole if fitted Switching On Off 1 Attach the desired tool to the quick release air outlet 2 To switch the compressor on pull the on off switch up into the on position 3 To swit...

Page 4: ...reached the motor will automatically switch Off As the compressed air is used the pressure will drop until it reaches the preset minimum pressure when the minimum pressure is reached the compressor wi...

Page 5: ...ating knob to a higher pressure The drain plug leaks Tighten the lever by hand Check the seal and replace if necessary The compressor starts pressure is shown on the pressure gauge but no pressure to...

Page 6: ...WITCHED OFF AND DISCONNECTED FROM THE POWER SUPPLY BEFORE PERFORMINGANYOF THE FOLLOWING PROCEDURES WARNING WAIT UNTIL THE COMPRESSOR HAS COMPLETELY COOLED DOWN RISK OF BURNS WARNING ALWAYS DEPRESSURIZ...

Page 7: ...Australia 1800 069 486 New Zealand 0508 069 486 E mail enquires ozito com au SPARE PARTS Wear hearing protection Warning Regulatory Compliance Mark RCM V Volts Hz W Hertz n0 min 1 Alternating Current...

Page 8: ...king people and blowing foreign particles into the air Do not attempt to catch the air line but immediately keep bystanders well clear and turn off the air supply to the hose turn off the compressor a...