Using the Memory Function
About Blood Pressure
Lower pressure
Relaxation of the
heart muscle
Pressure decreased
on arteries
Blood returns to heart
Higher pressure
Contraction of
the heart muscle
Pressure increased
on arteries
Blood outflow
Diastolic Blood Pressure
Systolic Blood Pressure
The blood circulation is responsible for supplying the body with oxygen.
Blood pressure is the pressure exerted on the arteries.
The systolic blood pressure value (higher pressure or top value) represents
the blood pressure produced by contraction of the heart muscle.
The diastolic blood pressure value (lower pressure or lower value)
represents the blood pressure produced by relaxation of the heart muscle.
Blood Circulation
About Blood Pressure
*Note:
When a person’s systolic and diastolic pressures fall into different categories,
the higher category should apply.
WHO
Red
Orange
Green
Diastolic Blood Pressure (mmHg)
Systolic Blood Pressure (mmHg)
Optimal
blood pressure
(target value)
Normal blood pressure
Normal systolic value
Mild hypertension
Moderate hypertension
Severe hypertension
After each measurement, the LCD will automatically classify the measured
blood pressure in to one of six categories, based on guidelines set by the
World Health Organization.
Classification of Blood Pressure
18
19
20
21
Using the Memory Function
This device stores the blood pressure and pulse rate in memory
after each measurement. It automatically stores 180
measurements for 2 users (2x90). The earliest record is deleted to
save the most recent measurement once 90 is reached.
How to Use the Memory Function
.......
Turn to next
the average value of
all measurement values
the average value of all
AM measurement values
the average value of all
PM measurement values
SET
MEM
To read the average value
Press the “MEM” button, the average value of the last 3 reading of the current
user will display when the symbol “L3” appears.
Press the “MEM” button two times, the average value of all measurement of the
current user will display.
Press the “MEM” button three times, the average value of AM measurement of
the current user will display when the “AM” symbol appears.
Press the “MEM” button four times, the average value of PM measurement of
the current user will display when the “PM” symbol appears.
the average value of
the last 3 reading of the
current user
While in memory reading mode, press and hold the “MEM” button first and then the
“SET” button for 3 to 4 seconds. Note this will delete all saved measurements.
To reset the memory
While in memory reading mode, press the “MEM” button to sequentially
display the measurements beginning with the most recent to the oldest.
Press the “SET” button sequentially to display the measurements beginning with
the oldest to most recent.
Reading the saved measurements
.......
.......
Backward
Forward
The 1st most recent
measurement
The 2nd most recent
measurement
The 90th and oldest
measurement
SET
Press the “MEM”
button to select
“YES” or “NO”, and
the START/STOP
“ ” to confirm.