6.2 Trouble Shooting and Repair Guide 

(       Refer all repair work to qualified technical service personnel!  )

6.3 Motor Driver Adjustments

CURRENT ADJUSTMENT PROCEDURE:

The motor driver board has an overcurrent protection feature with adjustable threshold by RV1.

1. 

Do not change speed setting unless  a replacement board is installed. Otherwise, set the speed at factory default .  

  

  

2. 

Adjust ‘current’ carefully by observing red  ‘overcurrent’ LED. The LED should blink for minimal duration each time the motor 

starts. If the led blinks too long and brightly, turn adjustment left (CCW) for minimal flash duration.  

Note: 

If the speed setting is changed, ‘current’ must be re-adjusted.

Caution!

 

Panel may stall and retreat with no obstacle if RV1 setting is too low. In this case turn RV1 counter clockwise to reduce sensitivity.

If the setting is too high then panel may exert excessive pressure on an obstacle. 

 

Description of Fault 

Possible Cause 

Recommended Action 

No power. (indicators, buzzer 

off) 

 

1. No AC power supplied to unit. 

2. Loose power cable 

3. Blown fuse  

4.

 

Faulty power supply unit 

1.Restore AC power. 

2. Connect power cable. 

3. Replace fuse (see 2.2) 

4. Replace power supply unit 

Turnsile does not allow 
passage when input contact 

is given-buzzer heard, 

indicator turns green  

1. Restricted panel movement (due to 
foreign object blocking movement) 

2. Motor driver circuit breaker tripped 

3. Loose motor connection 

4. Blown motor driver fuse

5.

1.Remove object 
2. Power off reset 

3. Repair connection 

4. Replace motor driver board fuse 

 

Panel oscillates right and left 

in the middle position 

1. Misaligned/ bent photosensor  

Adjust photosensor (reduce angle) 

No response to input/reader 

Turnstile remains open with 

alarm sound. 

device. No access 

1. Loose/incorrect reader connection 

2-Reader fault

1. Emergency (Emg) input jumper removed. 

2.Fire alarm relay connection fault.

1. Connect jumper on Emg-Gnd terminals

2.Repair fire alarm (NC)connection

 

3-Faulty control board 

1.Check/repair reader connections 

3-Replace faulty reader/input device  

4-Replace control board 

Motorized rotor/ panel keeps 

moving/ fails to stop in 

middle position.   

1. Loose photosensor connector 

2. Misaligned, bent or contaminated 

photosensor 

3. Faulty photosensor 

1. Repair/tighten photosensor connector 

2. Adjust/ clean photosensor 

3. Replace photosensor 

Motorized panel opens 

slowly and times out on 

return/ alarm activated. 

1. Too low motor speed setting on motor 

driver board 

 

1. Increase motor speed (turm speed control ccw 

direction) on motor driver board 

 

Speed Adj.

Overcurrent LED 

Current Adj.

5.

Electronic circuit protection activated

Power off reset

Summary of Contents for GL A1

Page 1: ...DD 75 193 R 0 Y T 31 03 17 1 GL A1 GL A2 INSTALLATION AND MAINTENANCE HANDBOOK www ozak t com DD 75 193 R 0 Y T 31 03 17 ...

Page 2: ...d Settings 4 3 1 Blocking Passage Direction 4 3 2 Timeout and Mode Settings by Dip Switch 4 4 Operating Instructions 5 POST INSTALLATION CHECK LIST 12 6 SERVICE AND MAINTENANCE 13 6 1 Maintenance Instructions 6 1 1 Recomended User Maintenance 6 1 2 Periodic Maintenance by Technical Service Personnel 6 2 Trouble Shooting Guide 6 3 Motor Driver Adjustments 6 4 Photo Sensor Replacement and Alignment ...

Page 3: ...te Star Galaxy Black stone top lid for a decorative and aesthetical appearance opt tempered glass stainless steel wood Indicator Features Built in circular RGB LED status indicators are located under the top lid Illumination is blue at stand by green during authorised passage flashing red for unauthorised attempts and green for emergency alert mode Operating Temperature Humidity IP Rating MCBF 20 ...

Page 4: ...nually in either direction in case of a power failure Wing Speed Wing speed is controlled by adjustable PWM controlled motor driver system For 900mm Passage Width Tempered Glass Wing Wing Opening Speed 3 0 seconds by default 2 5 3 5 sec adjustable Wing Closing Speed 3 0 seconds by default 2 5 3 5 sec adjustable For 550mm Passage Width Tempered Glass Wing Wing Opening Speed 2 7 seconds by default 2...

Page 5: ...or voltage fluctuations Dimensions Cylindrical body 1500mm x Ø230mm x Wing width 900mm Body Features 1mm thick single piece 304 Grade satin finished stainless steel cylindrical body Wing Features Wing is made of 4 0 1 52 4 0 mm laminated tempered 900 mm glass Wing length and 1500 1800 mm wing heights are available as standard choices Top Lid Features Stainless steel or natural granite Star Galaxy ...

Page 6: ... wing in either direction upon receiving contact to allow passage Glass wing automatically retreats when it pushes against an obstacle and goes into alarm after a second attempt Emergency Mode In case of emergency input the wing opens in either direction pre set direction by internal dip switch and the system stays in open position until the emergency input is removed Wing can be pushed open manua...

Page 7: ...T VİEW Gnd P N WARNING DİKKAT 220 V 50 Hz FUSE Gnd P N WARNING Never remove the protective cover of the power supply unit for any reason Observe the warning signs power and fuse values when performing any work on the turnstile Warning labels and power supplies may vary depending on the turnstile model and type CAUTION Use only original type and value replacement fuse 24 V DC Power Supply Spare Fus...

Page 8: ...uld be used for cleaning the turnstile 19 Damaged turnstiles must not be operated and the authorized dealer or the Manufacturers technical support center should be contacted soon as possible for repair 2 4 Operating Precautions 1 More than one person must not attempt to pass at the same time 2 Do not obstruct or apply force to the panel at any time 3 A locked turnstile must not be forced kicked ab...

Page 9: ...th chemical plaster and fix anchoring bolts size 8 in place by rotating Chemical plaster dries in about 25 minutes 3 Place turnstile on anchoring bolts and tighten the nuts to secure in place Pay attention to triangle panel position marker during surface mounting 4 Connect power and control cables 5 Re install cylindirical body 6 Remove display unit mounting screw 1 7 Remove glass fixing screw 2 8...

Page 10: ...le Routing Area Note For optimal flow rate contact duration of 1 second or less is recomended SN Access Control Terminal Res 24V B A B A or A B A B N O N O Com Com Gnd Gnd Emg INB Gnd Gnd Gnd Gnd INA 1 2 3 7 5 6 8 Power B A A B J3 Top Indicators Side Indicators Motor Control Direction Sensors ON DipSwitch 1 2 3 4 U2 U7 U1 RL1 RL2 U9 A B Prg XXXXXXXXXXX Rx Tx I O_1 I O_2 I O_3 I O_4 Out_P3 Out_P2 O...

Page 11: ... T A N A L P X E 2 1 F F O F F O Entry Time Out 6 Seconds F F O N O Entry Time Out 12 Seconds N O F F O Entry Time Out 2 Seconds N O N O Entry Time Out Infinite PANEL OPENING DIRECTION IN EMERGENCY W S N O I T A N A L P X E 3 F F O OPEN CLOCKWISE IN EMERGENCY N O OPEN COUNTERCLOCKWISE IN EMERGENCY BUTTON MODE SELECTOR W S N O I T A N A L P X E F F O SEPARATE OPEN AND CLOSE BUTTONS N O OPEN AND CLO...

Page 12: ... sufficiently strong 2 All wiring is routed and connected properly 3 All AC power lines are properly insulated and grounded 4 Turnstile is positioned and mounted correctly and firmly 5 All anchoring bolts are secured in place with chemical plaster 6 All anchoring hardware tightened properly no loose nuts bolts etc 7 Panel covers readers etc are mounted correctly Panel is securely bolted in place 8...

Page 13: ... excellent corrosion resistance Depending on the environmental conditions there may be tea staining issues on some turnstile surfaces in moist dusty areas if regular cleaning and maintenance is not performed On 304 and higher grade steel surfaces these stains are not actual rust but only accumulation of airborne particles sticking on the surfaces These type of stains can be cleaned off and prevent...

Page 14: ... not allow passage when input contact is given buzzer heard indicator turns green 1 Restricted panel movement due to foreign object blocking movement 2 Motor driver circuit breaker tripped 3 Loose motor connection 4 Blown motor driver fuse 5 1 Remove object 2 Power off reset 3 Repair connection 4 Replace motor driver board fuse Panel oscillates right and left in the middle position 1 Misaligned be...

Page 15: ...rs 4 Remove Photosensor Unit 5 Check new photosensor for proper centering 6 Check photosensors for proper alignment 8 Check align sensors for proper clearance with disc and all moving parts 2 Move mechanism to center position 7 Install photosensor unit follow removal steps in reverse order Insert into plug 6 CAUTION Do not insert into any other plug This will damage photosensor unit 12 ...

Page 16: ... 6 Remove remaining motor mounting bolt by10 mm wrench and remove motor Follow stepsin reverse to install new motor 1 Turn rotor to gain access to sensor fixing screw Remove screw by 3mm allen key while holding bottom nut with 7 mm wrench 2 Carefully push photosensor unit back for access to motor mounting bolts 3 Loosen lock screw by 4 mm allen key ...

Page 17: ... out Batt Gnd SN Res 24V B A A B N O N O Com Com Gnd Gnd Emg INB Gnd Gnd INA 1 2 3 7 5 6 8 Power B A A B J3 Direction Sensors ON DipSwitch 1 2 3 4 U2 U7 U1 RL1 RL2 U9 Prg XXXXXXXXXXX Rx Tx I O_1 I O_2 I O_3 I O_4 Out_P3 Out_P2 Out_P1 5 V 24 V Gnd TRN1202 Gnd Enable 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 1 2 3 4 5 6 BLACK Dr R onn 2 V2 4 Gnd r D a Co Q2 U3 RV 7 7 3 ON Dip 1 24 V Gnd or Data 7 7 2 ...

Page 18: ...1 Motor Out Brown 2 Motor Out Blue 9 MOTOR OUT 1 2 Match socket and cable numbers when replacing boards and other parts Pay attention to pin markers when replacing microprocessors CONTROL BOARD 1 2 3 4 Sensor 2 Data In Gnd 24Vdc Sensor 1 Data In 6 PHOTO SENSOR INPUT 1 Gnd 2 24Vdc POWER 8 1 2 3 4 5 6 n c n c 3 n c RGB LED STRIPE n c Blue Led Stripe Red Led Stripe 1 Relay Out 1 Red 1 5 not used 1 2 ...

Page 19: ...iver Board MC24 30 01 03 0011 7 Power supply SMPS 100W 24V 10 01 35 0013 8 RGB Indicator Led 45 00 00 0004 9 Rubber Stop 20 02 03 0023 Top Lid Marble 30 03 00 1144 10 Cylinder 30 03 00 0020 Use only original Özak replacement parts 2 4 1 6 5 3 7 9 10 Panel type and size can vary depanding on option choosen Please provide model and serial number of the turnstile when ordering parts Part numbers can ...

Page 20: ...EL DATE OF DELIVERY WARRANTY PERIOD SERIAL NUMBER MANUFACTURER ÖZAK GEÇİŞ TEKNOLOJİLERİ SANAYİ TİC A Ş ADDRESS Çuhane CD N0 130 41080 KÖSEKÖY KOCAELİ TURKEY PHONE FAX 90 262 373 48 48 Pbx E MAIL ozak ozak t com WEB www ozak t com T S E K TS EN ISO 9001 2008 T 233 01 ...

Page 21: ...following the date of purchase excluding failures resulting from physical damage incorrect installation misuse tampering and similar reasons beyond manufacturers control 1 Any tampering or damage on warranty certificate or serial numbers and labels that prevent the identification of the product shall void the warranty 2 Any modifications addition of accessories and parts or replacement of parts wi...

Page 22: ...ES İlgili Direktifler Relevant Directives 2006 42 EC Makine Yönetmeliği Machinery Directive 2014 35 EU Alçak Gerilim Yönetmeliği Low Voltage Directive İsim Name ÖZER ÖZALP Ünvan Title GENEL MÜDÜR GENERAL MANAGER Yer ve Tarih Place and Date KOCAELİ 11 07 16 İmza Signature CE UYGUNLUK DEKLARASYONU CE DECLARATION OF CONFORMITY ÖZAK GEÇİŞ TEKNOLOJİLERİ SANAYİ TİC A Ş hereby declare that the above list...