background image

 

 

 

ALL RIGHTS RESERVED 

 

2. ELECTRICAL SET-UP (standard system) 

 
 
 
 
 
 
 
 
 
 
 

 

1) Motor TYPHON 2000 

 

2) Photocells 
3) Key selector 
4) Flashing lamp 
5) Radio receiver

 

Fig. 2 

 

3. INSTALLING THE AUTOMATISM 

 

3.1. Preliminary checks 

 

To ensure safety and efficiency of the automated system, make 
sure  the  following  requirements  are  observed  before  installing 
the system: 

 

•  The  gate  structure  must  be  suitable  for  automation.  In 

particular the following requirements are necessary: 

-  The wheel diameter must be in proportion to the weight of the 

gate, an upper track must be provided, plus mechanical travel 
stops to prevent the gate derailing. 

 

• The soil must guarantee a perfect stability of the foundation 

plinth. 

 

•  There  must  be  no  pipes  or  electric  cables  in  the  plinth 

excavation area. 

 

• If the gear motor is located in the vehicle transit or manoeuvre 

area, adequate means of protection should be provided against 
accidental impact. 

 

• Check if an efficient grounding is available for the connection 

to the gear motor. 

 

3.2. MASONRY FOR FOUNDATION PLATE 

 

1- Assemble the foundation plate as shown in figure 05. 

 

2- In order to ensure that the pinion and rack engage correctly, 
the  foundation  plate  must  be  positioned  as  shown  in  Fig.  03 
(right closing) or Fig. 04 (left closing). 

 

Warning: 

The hole for the cables on the foundation plate

 

must 

always point to the gate, see Fig. 05. 

 

3- After determining the position of the foundation plate, make a 
plinth as shown in Fig. 06 and wall the plate, providing several 
sheaths for routing the cables. Using a spirit level, check if the 
plate is perfectly level. Wait for the cement to set. 

 

4- Lay the electric cables for connection to the accessories and 
power  supply  as  shown  in  the  diagram  of  Fig.  02.  To  facilitate 
connections to the control unit, allow the cables to protrude by 
at least 45 cm from the hole on the foundation plate. 

 

3.3. MECHANICAL INSTALLATION 

 

1-  Remove  the  cover  and  position  the  operator  on  the 
foundation  plate,  using  the  supplied  washers  and  nuts.  During 
this  operation,  route  the  cables  through  the  appropriate 
openings in the motor body. 

 

2- Adjust the height of the gear motor and the distance from the 
gate, referring to the dimensions in Fig.6. 

 

Attention:  This  operation  is  necessary  to  ensure  the  correct 
securing of the rack and to enable any new adjustments. 
4- Secure the gear motor to the plate, tightening the nuts. 

 
 
 
 
 

 

Fig. 3 

 

160

 

 

286 

 
 
 
 

Fig. 4 

 

160

 

 

286 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig. 5 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Fig. 6 

Summary of Contents for TYPHON 2000

Page 1: ...TYPHON 2000 Manual for the installation and maintenance of automations for sliding gates ENGLISH...

Page 2: ...wer supply 12 The mains power supply of the automated system must be fitted with an all pole switch with contact opening distance of 3mm or greater Use of a 6A thermal breaker with all pole circuit br...

Page 3: ...y of 40 To ensure efficient operation it is necessary to operate in the work range below the curve Important The curve is obtained at a temperature of 20 C Exposure to the direct sun rays can reduce t...

Page 4: ...re that the pinion and rack engage correctly the foundation plate must be positioned as shown in Fig 03 right closing or Fig 04 left closing Warning The hole for the cables on the foundation plate mus...

Page 5: ...bottom of the slot 3 Mark the drilling point on the gate Drill a 6 5 mm hole and thread with an M8 male tap Screw the bolt 4 Move the gate manually checking if the rack is resting on the pinion and r...

Page 6: ...RESTORING NORMAL OPERATION To prevent an inadvertent boost from moving the gate during the manoeuvre turn off the power supply before locking the motor again RELEASE LEVER 1 Close the release lever 2...

Page 7: ...ated system is ideal for controlling vehicle access areas of medium transit frequency TYPHON 2000 system for sliding gates is an electro mechanical operator transmitting motion to the sliding gate wit...

Page 8: ...bled with other machinery to constitute machinery under the Directive 98 37 CEE and subsequent amendments 2 meets the essential safety requirements of the following Directives CEE 73 23 CEE and subseq...

Page 9: ...tronic box hinge 9 Support spring limit switch 1 0 Limit switch box base 1 1 Limit switch cover 1 2 Electric box base 1 3 Electric box cover 1 4 External cover 1 5 MSC lock 1 6 Fold TRANSMISSION AND U...

Reviews: