Oxygen Automation strongly suggests to install mechanical stops, both in opening and in closing, for an accurate and reliable installation in time. 
The Hydra control unit works with working times and adds a few seconds automatically to always guarantee total opening and closing in all conditions (bad 
weather, strong wind, snow and rust). If you do not have mechanical stops, you must enable the slowdowns (DIP6 = ON) 

 

QUICK SETUP 

1) Make two jumpers between 11 - 17 and 11-18 and set DIP n. 4, 9, 10, 11, 12 to ON so that all safety devices (factory) are excluded 7 LEDs on 
2) Check that the capacitors are connected between the black and brown cables of each motor (in parallel). 
The colors of the cables are: Grey = common, Brown and Black = opening and closing 
3) To save the remote controls: 
- You can save the remote controls only if the gate is closed. 
- Leave DIP2 = OFF (factory) 
- Switch on the card with the 230V and wait for the gate to close automatically (if it opens, invert the brown and black of the motors) If it stays still, it means that 
it is already closed 
- With the gate closed, press and release button P1, the LED lights up 
- Press a button on the remote control, the LED flashes 
- Wait 10 seconds until the LED goes out = Remote control programmed 
If this procedure does not work, perform the RESET memory procedure and repeat it. 
4) Follow the "Time setting" procedure step by step, with one or two doors depending on your kit. Do not press the P1 button in case of 2 doors. 
5) connect the external photocells as shown in figure 2 (If it has two pairs of photocells, the two contacts of the receivers must be connected in series) 
Remove the jumper between 11 and 18. Do not remove the jumper 11 -17. 
6) Optional, connect the external light as shown in figure 1 (to activate the flashing) 
7) Adjust the force, as indicated in the relevant chapter. A correct setting is between 3 and 5 flashes for electro-mechanical motors. 
8) Oxygen Automation's Technical Service is available in any case: [email protected] 
 

CONNECTIONS 

N.

 

CLAMPS 

 1 - 2 

230V LIVE AND NEUTRAL 

MOTOR 1 OPENING 

MOTOR 1 COMMON 

MOTOR 1 CLOSING 

MOTOR 2 OPENING 

MOTOR 2 COMMON 

MOTOR 2 CLOSING 

9 – 10 

FIXED LAMP 

11 

ACCESSORIES COMMON  

12 

NC

 OPEN LIMIT SWITCH M1  

13 

NC

 CLOSE LIMIT SWITCH M1  

14 

NC

 OPEN LIMIT SWITCH M2 

15 

NC

 CLOSE LIMIT SWITCH M2 

16 

NO 

START

 

17 

NC 

STOP

 

18 

NC 

CLOSING PHOTOCELLS

 

19 

NO 

PEDESTRIAN START

 

20 

NC 

OPENING PHOTOCELLS

 

21 

24VAC ACCESSORIES 

22 

0 VAC ACCES LOCK 

23 

12 VAC ELECTRIC LOCK 

24 

ANTENNA COMMON 

25 

ANTENNA INPUT 

26 - 27 

FLASHING LAMP CONTACT 

 

DIP SWITCH SETTING 

DIP 

ON 

OFF 

TIME SETTING MODE 

STANDARD MODE 

STEP BY STEP MODE 

RESIDENTIAL MODE 

CONDOMINIUM ON 

CONDOMINIUM OFF 

DISABLE

 INPUT 20 

ENABLE

 INPUT 20 

ELECTRIC  LOCK 

ON

 

ELECTRIC  LOCK 

OFF

 

SLOWDOWN 

ON

 

SLOWDOWN 

OFF

 

+3 MIN. LAMP 

OFF

 

+3 MIN. LAMP 

ON

 

HYDRAULIC

 MOTORS 

MECHANIC

 MOTORS 

DISABLE

 INPUT 12 

ENABLE

 INPUT 12 

10 

DISABLE

 INPUT 13 

ENABLE

 INPUT 13 

11 

DISABLE

 INPUT 14 

ENABLE

 INPUT 14 

12 

DISABLE

 INPUT 15 

ENABLE

 INPUT 15 

- Step-by-step = automatic closing disabled  
- Residential = step-by-step with automatic closing - 
Condominium = does not accept other STARTs during 
opening 
*Hydraulic Motor Settings: DIP 8 = ON and DIP 6 = 
OFF 

 

 

REMOTE CONTROL (KEY FOBS)  

REMOTE CONTROLS STORE 

Press and release button P1, LED automatically lights up 
- Press a button on the remote control, the LED flashes, Remote control 
saved 
-As long as the LED is on, additional remote controls can be added. 
- Wait 10 seconds until the LED turns off automatically. 

*You can save remote controls only if the gate is closed: Set DIP2=OFF, switch-
on main power supply and wait for the gate to close automatically. 
 

PEDESTRIAN REMOTE CONTROL BUTTON STORE 

- Press and release button P1 twice, the LED automatically lights up 
solidly, flashes and lights up solidly again 
- Press another button on the remote control, the LED flashes, Remote 
control saved, as long as the LED is on you can add additional remote 
controls 
-Wait about 10 seconds until the LED turns off automatically 
 

 

 

MEMORY RESET 

Press and hold button P1, LED automatically lights up solidly 
- Press and hold P1 until the LED goes out. 
- Release P1, LED flashes, Memory is empty 

 

GATE TIME SETTINGS 

TWO WINGS GATE SETTING (TWO MOTORS)

 

SINGLE WING GATE SETTING (ONE MOTOR)

 

- Gate Closed  
- Set Dip Switch N.1 = 

On

  

- Press Remote Control Button -

 First wing opens  

- Wait for wing displacement (we suggest 2 Or 3 seconds)  

- Press Remote Control Button 

- Second wing opens  

- First wing is opened - Wait for 1 or 2 seconds - 

Press Remote Control Button 

to stop it  

- Second wing is opened – Wait for 1 or 2 seconds - 

Press Remote Control Button 

to 

stop it  
- Wait for desired pause time in opening (normally between 10 and 30 seconds)  

- Press Remote Control Button -

 Second wing closes  

- Wait for wing displacement (we suggest 2 or 3 seconds)  

- Press Remote Control Button 

- First wing closes  

- Second wing is closed - Wait for 1 or 2 seconds - 

Press Remote Control Button 

to stop 

it  
- First wing is closed - Wait for 1 or 2 seconds - 

Press Remote Control Button 

to stop it  

- Set Dip Switch N.1 = 

Off

 

- Gate Closed 
- Set Dip Switch N.1 = 

On

 

Press P1 Button

 on the control unit - Wing opens 

- Wing is opened - Wait for 1 or 2 seconds - 

Press Remote Control Button 

to stop it

 

- Wait for desired pause time in opening (normally between 10 And 30 Seconds)  

- Press Remote Control Button -

 Wing closes  

- Wing is closed - Wait for 1 or 2 seconds - 

Press Remote Control Button 

to stop it  

- Set Dip Switch N.1 = Off 

FURTHER SETTINGS  

PEDESTRIAN GATE SETTING

 

FORCE ADJUSTMENT

 

FAST CLOSING* 

 

- Gate Closed 
- Set Dip Switch N.1 = 

On

 

- Press Pedestrian Remote Control Button

 – First wing opens 

- Wait for desired opening angle - 

Press Pedestrian Remote Control Button 

to stop it  

- Wait for desired pause time in opening (normally between 5 and 10 seconds)  

- Press Pedestrian Remote Control Button -

 Wing closes  

- Wing is closed - Wait for 1 or 2 seconds - 

Press Remote Control Button 

to stop it  

- Set Dip Switch N.1 = Off 

- Gate closed 

Press Remote Control Button

 – First wing 

opens 
- During the opening 

Press P1 Button 

to 

decrease the force of 10% (up to 6 levels)  
- Switch off 230v main power 
- Switch on 230v main power, Prog Led 
automatically flashes, between 7 and 1 (7=Max  
1=Min) 
*If Set Dip 8 to on = Max force (7 flashes) 

- During gate time setting, during 
desired pause time (gate is fully 
opened and stopped) 

Activate photocells for 2-3 

seconds

 – Prog Led flashes – fast 

closing is activated 

*fast closing function : 

during pause the gate closes 3 seconds after having released the photocells

 

 

Summary of Contents for HYDRA 230V

Page 1: ...re la sicurezza dell impianto Tutti i materiali presenti nell imballo non devono essere lasciati alla portata dei bambini in quanto fonti di pericolo ATTENTION L alimentation principale doit être coupée pendant le câblage L installation et la maintenance ne doivent être effectuées que par du personnel qualifié conformément à la législation de référence Le fabricant ne peut être tenu responsable de...

Page 2: ...pt other STARTs during opening Hydraulic Motor Settings DIP 8 ON and DIP 6 OFF REMOTE CONTROL KEY FOBS REMOTE CONTROLS STORE Press and release button P1 LED automatically lights up Press a button on the remote control the LED flashes Remote control saved As long as the LED is on additional remote controls can be added Wait 10 seconds until the LED turns off automatically You can save remote contro...

Page 3: ...comandi Attendere 10 secondi finché il LED non si spegne automaticamente È possibile memorizzare i telecomandi solamente a cancello chiuso Impostare DIP2 OFF alimentare la scheda con la 230V ed attendere che il cancello chiuda automaticamente MEMORIZZAZIONE TASTO DI APERTURA PEDONALE Premere e rilasciare il pulsante P1 due volte il LED automaticamente si accende fisso lampeggia e si riaccende fiss...

Page 4: ...de télécommande la lumière LED clignote la télécommande est enregistrée Tant que la lumière LED est allumé il est possible d ajouter plus de télécommandes Attender 10 secondes jusqu à ce que la lumière LED s éteigne automatiquement Vous pouvez enregistrer les télécommandes seulement quand le portail est fermé Réglez DIP2 OFF allumez l alimentation principale et attendez la fermeture automatique du...

Page 5: ...ingeschaltet ist ist es möglich weitere Fernbedienungen hinzuzufügen Warten Sie 10 Sek bis sich die LED automatisch ausschaltet Es ist möglich die Fernbedienungen zu speichern nur wenn das Tor geschlossen ist Stellen Sie DIP2 auf OFF ein speisen Sie die Netzteilkarte mit der von 230V und warten auf das automatische Schließen des Tores SPEICHERUNG DER FUßGÄNGERZUGANGSFUNKTION TEILÖFFNUNG Drücken un...

Page 6: ... el botón P1 el LED se enciende automáticamente Pulse un botón en el mando a distancia el LED parpadeará y el mando a distancia se guardará Mientras el LED esté encendido se pueden añadir controles remotos adicionales Espere 10 segundos hasta que el LED se apague automáticamente Los mandos a distancia sólo se pueden memorizar con la cancela cerrada programar DIP2 OFF alimentar la tarjeta con 230V ...

Reviews: