Model

OXD-844-2040K

OXD-844-2070K

Max. Capacity

6kg/12lb

15kg/33lb

Readability

1g/0.002lb

2g/0.005lb

Display Resolution

1:6000

1:7500

Min. Recommended Weight

20g

40g

Min. Piece Weight

0.1g/0.00022lb

0.2g/0.0005lb

Construction

Stainless steel pan, plastic housing

Weighing Units

kg/lb

Calibration Unit

kg/lb

Modes

Weighing, Counting, Accumulation, Data Compare

Weight Display

Three 7-segment LED display windows, 0.6” High, 6-digit

Memory

256 entries

Zero Range

Power-on zero range: calibration zero point±15%FS; ZERO 

key range: power-on zero±5%FS

Tare Range

Full capacity

Stabilisation Time

<5 seconds

Operating Temperature

32˚ to 105˚F (0˚ to 40˚C)

Humidity Range

<90% relative humidity, non-condensing   

Power Supply

6V 4A rechargeable lead-acid battery or AC Power adapter 

(12Vdc/500mA with central positive)

Battery Performance

Up to 12 hours when fully charged

External Interface

RS232

Safe Overload Capacity

120% of capacity

Platter Dimensions (L x W)

290 x 220mm (11.4” x 8.7”)

Scale Dimensions (L x W x H)

294 x 342 x 115mm (13.5” x 11.6” x 4.5”)

SPECIFICATION

OXD-844-2040K-INSTRUCTIONS.indd   3

OXD-844-2040K-INSTRUCTIONS.indd   3

29/06/2020   10:07

29/06/2020   10:07

Summary of Contents for OXD-844-2040K

Page 1: ...K cromwell co uk Battery or mains powered Suitable for office Postroom stores applications Large clear digital display Dual reading metric or imperial Capacities 6kg 12lb OXD 844 2040K INSTRUCTIONS in...

Page 2: ...the weighing plate In some circumstances the internal sensor may be damaged by inappropriate use The item to be weighed should be placed carefully onto the scales and the display allowed to stabilise...

Page 3: ...range calibration zero point 15 FS ZERO key range power on zero 5 FS Tare Range Full capacity Stabilisation Time 5 seconds Operating Temperature 32 to 105 F 0 to 40 C Humidity Range 90 relative humidi...

Page 4: ...s for 4 seconds to clear data or accumulated values Enter Confirms the operation or saves the data Print Outputs data via the RS232 port Accu Accumulates the current weighed values Press for 4 seconds...

Page 5: ...scales allow 10 minutes for them to warm up before use for optimum results 2 Press the ZERO ON OFF key to turn on the scales The self check will run and the scales will display a zero reading The sca...

Page 6: ...MULATION MODE The accumulation function allows storage of weighed piece quantities and the summation of those quantities 1 With an object on the scale press and release the ACCU key to add the display...

Page 7: ...tone will sound 1 From normal weighing mode press the Hi Lo key to enter this mode The WEIGHT window will show the current weight and the PIECE WEIGHT window will show Hi PCS High limit pieces The COU...

Page 8: ...o confirm or press the ZERO ON OFF key to exit this mode a If you selected PCT 0 to calculate the piece weight the COUNT window will show SPL SAMPLE Place samples on platter and the PIECE WEIGHT windo...

Page 9: ...reading is stable press PRINT key to output the data via RS232 interface in the following format Business xxxxx Product xxxxx ID xxxxxx Date yy mm dd Time hh mm Gross xxx xxx kg lb Tare xxx xxx kg lb...

Page 10: ...cator stops flashing press the ENTER key to confirm the standard weight point calibration or press the ZERO ON OFF key to exit this mode After the standard weight point is confirmed the scale will aut...

Page 11: ...y range 5 Make sure scale platform is empty Power off scale and power on again Perform zero calibration Err05 Weight is below Power On Zero limit 15 or below ZERO key range 5 Install platform on scale...

Page 12: ...ecycling facility Do not dispose of electrical goods with domestic waste materials as inappropriate disposal may cause potential hazards to the environment and human health For further information ple...

Reviews: