background image

1.   Switch on the caliper by pressing the mode button (to switch off the caliper press and 

hold down the set button).

2.  Loosen the locking screw and move the slider to bring the outside faces together and set  

 

zero by pressing the set button.

3.  To select mm or inches, press the mode button three times, ‘unit’ will appear, press the  

 

set button to toggle between mm and inches then press the mode button to select the  

 

option you desire. Set zero by pressing the set button.

1.  Press    turn on and shut down.

2.  Move the slider to the proposed zero point.

3.  Press the INC button (= relative reading) 

4.  Measurements will now read ± from the chosen relative zero point.

5.  Press MODE to switch to mm/inch

6.  During this operation, if you decide you want a reading from the absolute zero simply 

press the “0” button button again to take reading.

7.  You will then need to reset the chosen relative zero point.

External Dimensions

Put the workpiece as close to the reference 

surface as possible, and have the measuring 

faces firmly in contact with the workpiece 

without excessive force.

Depth Measurement

For depth measurement, set the depth bar 

perpendicular to the measured surfaces.

Internal Dimensions

For inside measurement, put the inside  

jaws as deep as possible and have the  

measuring faces firmly in contact with the 

workpiece without excessive force.

Step Measurement

For step measurement, have the  

step-measuring-faces firmly in contact  

with the workpiece.

Operating Instructions

Replacing Battery

Relative Measurement

Taking Measurement

The steps given below must be followed to replace the battery when the power is low.

l

  Insert the b side facing up. Inserting the battery upside down may result in 

caliper failure.

l

  If the display on the digital caliper does not show “

0.00

” after the battery change, 

remove battery and insert again.

l

  Your Oxford caliper is supplied with with one 

CR2032 Li-ION 

battery

Step one

Take the old one

Step Two

Put a new one inside

Step Three

Snap it tightly

Step Five

Close the jaws and press the  

“0” key to reset

Step Four

Put the cover back

Reviews: