User Manual of PDS Series Oscilloscope
42
used to set the horizontal scale and position.
The
Vertical VOLTS/DIV
and the
Vertical POSITION
knobs
of Channel 2
are used to set the vertical scale and position continuously.
Notes: The following functions would be disabled when XY Format is set.
Reference or Any calculated l wave form
Cursor Function
All time base controls
All Trigger controls
Use XY Format
1.
Apply input signals to both CH1 and CH2
2.
Press the
DISPLAY
to activate
DISP Set
menu.
3.
Press
F1
to set Vectors as type,
F2
to set Infinite for persist and
F3
to set XY as
Format as shown as Fig.43
Fig.43
Display in XY Format
To Save and Recall a Waveform
Our PDS series Digital Oscilloscope is capable to save up to four wave forms. Stores
waveform can be recalled for review later. To active this function, Press the
SAVE/RCL to bring up WAVE SAVE menu. Details of setting and functions are
shown in Fig.44.