10
Step delay: The delay that jumps to the next step after each step is completed;
Dry contact control: Whether to enable the dry contact control function during
discharge time.
Cycle number: The number of loops that perform one full step at a time;
Single-step setting: Each step outputs a control containing reference voltage/current,
a judgment voltage/current setting, and a charge/discharge time setting;
Note: 1. Each step of the execution logic: Reference voltage and current parameters control
output ---> Detect the output voltage to reach the judgment voltage ---> The output
current detected is less than the judgment current ---> Turn off the output, enter the
charging period and time ---> At the end of the charging period, enter the discharge
period and time, if dry contact control is enabled, dry contact action ---> When the
discharge period ends, close the dry contact and go to the next step.
2. Charging time is the time from voltage and current judgment logic of each step to
discharge time (float charging time).
3. Discharge time is the time from the completion of each charge time to the next step,
during which the output will be closed. Generally used for external discharge of energy
storage medium, can enable "Dry contact control" to control the switch between charging
circuit and external discharge circuit.
3.1.3 Function Generator Mode
Wave
:
Sine Wave
▼
Ref
:
XX.XXX V
CV
▼
Periods
:
Infinite
Parameter Of Wave
:
Amplitude:
XX.XXX V
Period
:
XXXXX
S
▼
Interval Time
:
XXXXX
S
▼
Table 6: Sine wave generator
Superimpose sine waves on the DC reference.
Wave
:
TriangularWave
▼
Ref
:
XX.XXX V
CV
▼
Periods
:
Infinite
Parameter Of Wave
:
Amplitude
:
XX.XXX V
Rise Time
:
XXXXX
S
▼
Fall Time
:
XXXXX
S
▼
Interval Time
:
XXXXX
S
▼
Table 7: Triangle wave generator
Superimpose triangle or sawtooth waves on the DC reference.