27
SECTION 6: OPERATION/MAINTENANCE
LIVE MODE OPERATION
LIVE MODE is an advanced feature that periodically updates the OTDR
screen while the OTDR is taking a trace, in order to view events as they
happen in real-time.
LIVE MODE OPERATION
Press
from the trace screen until the following menu options appear:
opens the TRACE OPTIONS menu
highlight CAPTURE MODE
change the value to LIVE
Press SAVE to return to the trace screen. The function menu should show:
Press
to start LIVE mode. After a few seconds the OTDR
screen will acquire its initial trace.
After acquiring its initial trace, the trace screen will begin to update every few
seconds.
The frequency of screen updates will depend upon the selected
TRACE OPTIONS. Lowering the number of samples and/or
increasing the STEP value will increase the frequency of screen
updates, but will also lower the trace resolution.
f the screen does not appear to be changing, the characteristics of
the fiber are not changing.
I
When the OTDR is connected to a PC, OWLView software allows
users to display LIVE mode on the software trace screen. This
enables users to view real-time trace updates on the large PC
monitor in order to better see events that may not be visible on the
OTDR LCD display.
To enable LIVE mode in OWLView software:
1)
Launch OWLView software;
2)
Click “Start Live Mode”
3)
If the OTDR is not already in LIVE mode, follow the
instructions that appear on the software screen, wait for
LIVE mode on the OTDR to begin, then click “Start Live Mode” again.
When LIVE testing is complete, press
again to exit LIVE mode.
SETUP
TEST
TEST
6086m
20226m
24718m
RFL dB
-81.00
14140
dB
2.43
3.34
L m
Fiber #
TEST
ZOOM
LOCK
CURSOR
ENTER
1550nm
LIVE
H
SETUP
INDEX
LOAD
SAVE
TRACE OPTIONS
CAPTURE MODE
PULSE WIDTH
NUMBER OF
SAMPLES
DEAD ZONE
LENGTH(m)
RANGE
STEP
SAVE
QUIT
HELP
LIVE
1m
4096
1100
MAXkm
1m
TEST
ZOOM
LOCK
CURSOR