background image

REQUIRED ACCESSORIES

?

(2) singlemode patch cables

EQUIPMENT PORTS

Figure 1 shows the ports of the equipment used during this procedure.   These ports may vary depending upon the 
model of equipment.

VERIFY PROPER OPERATION OF THE EQUIPMENT

STEP 1

Connect the power meter and light source together with one of the patch cables as shown in Figure 2. 

STEP 2

Power on the light source.

STEP 3

Press 

<PORT> 

to set the WaveSource to the SM PORT.

STEP 4

Power on the Micro OWL 2.

STEP 5

From the OPERATING MODE menu, select SIMPLE METER.

STEP 6

Press

 <F3>

 on the Micro OWL 2 until the wavelength reads 1310nm.

STEP 7

The Micro OWL 2 should read approximately -10.00 dBm.   If the reading is below -12.00 dBm, the 

patch cable should be replaced.

STEP 8

Once proper operation has been verified, remove the first patch cable from both units and set it aside.

STEP 9

Connect the second singlemode patch cable between the Micro OWL 2 and the WaveSource as shown 

in Figure 2.

STEP 10

The Micro OWL 2 should read approximately -10.00 dBm.   If the reading is below -12.00 dBm, the 

patch cable should be replaced.

STEP 11

Once proper operation has been verified, press 

<DONE>

 to return to the OPERATING MODE menu.

Detector 

Micro OWL 2 power meter

1310nm /
1550 nm

FIGURE 1

Test Equipment Ports

WaveSource light source

FIGURE 2

Singlemode
Patch Cable

Connection 

 LIGHT SOURCE CONNECTOR 

PORT NOTES:

– CONNECTOR TYPE MAY VARY
– DO NOT INSERT ANGLED 

PHYSICAL CONTACT (APC) 
CONNECTOR

Summary of Contents for Micro OWL 2 Series

Page 1: ...73 0643 Internet OWL INC COM Revision 1 1 26009 Micro OWL 2 Series Test Kits Certification Testing Quick Reference Guide For part numbers KIT M2 WSSDst KIT M2 WSSDsc KIT M2 WSSDfc Optical Wavelength Laboratories e C s i h o W i c e e h i T n O s p e i t r i c o a t l a r F o i b b e a r L T h e t s g t n E e l q e u v i p a m W e l n a t c i t p O OWL ...

Page 2: ...or fail by Complete understanding of each of these issues is critical for performing proper fiber optic tests GETTING STARTED Thank you for your purchase of this OWL certification test kit Included in this kit is a Micro OWL 2 optical power meter and a WaveSource multimode fiber optic light source This quick reference guide will assist you in setting up your test kit for a standards based certific...

Page 3: ... should read approximately 10 00 dBm If the reading is below 12 00 dBm the patch cable should be replaced STEP 8 Once proper operation has been verified remove the first patch cable from both units and set it aside STEP 9 Connect the second singlemode patch cable between the Micro OWL 2 and the WaveSource as shown in Figure 2 STEP 10 The Micro OWL 2 should read approximately 10 00 dBm If the readi...

Page 4: ...rtification reports XXXXXXXXXXXXXXXXXXXXX X X XXXXXX 1 LINK WIZARD X X XXXXXXXX 2 MAIN MENU XXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXX XXXXX X XXXXXX START MENU XXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXX XX x x xXxxxxx Fiber Link 2 x XX XXXXXXXX NEXT SELECT XX x x xXxxxxx Fiber Link 3 XX x x xxXxxxx Fiber Link 4 XXXX X XXXXX STORED LINKS _____________________ XX x x Xxxxxxx...

Page 5: ...o wavelengths press the 1 button to set the Micro OWL 2 into AUTO mode then press and hold the 8 AUTO button on the WaveSource You will begin to see the WaveSource indicator LED alternate between and STEP 31 Disconnect the mandrel wrapped patch cable from the Micro OWL 2 and take the units to opposite ends of the link STEP 32 Connect the units to the first fiber to test as shown in Figure 3 Your r...

Page 6: ...e first fiber in the link you may be prompted to enter a new label STEP 34 Press F3 to save the data point STEP 35 Disconnect the patch cables from the patch panels and move them to the next port in the patch panel then repeat steps 33 through 35 until all fibers in the link have been tested ...

Reviews: