CAUTION  

RISK OF ELECTRIC SHOCK 

 

DO NOT OPEN  

 

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK 

DO NOT REMOVE COVER (OR BACK) 

NO USER-SERVICEABLE PARTS INSIDE 

REFER SERVICING TO QUALIFIED PERSONNEL 

 

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user 
to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of 
sufficient magnitude to constitute a risk of electric shock to persons. 

 

 

The exclamation point within an equilateral triangle is intended to alert the user of the presence of 
important operating and maintenance (servicing) instructions in the literature accompanying the 
appliance. 

 

 
 

The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as 
vases, shall be placed on the apparatus. 

 
 
 

IMPORTANT SAFETY INSTRUCTIONS 

 

1.

 

Read these instructions - All the safety and operation instructions should be read before this OWI product is 
operated. 

2.

 

Keep these instructions - The safety and operating instructions should be kept for future reference. 

3.

 

Heed all warnings - All warnings on this product and in these operating instructions should be followed. 

4.

 

Follow all instructions - All operating and other instructions should be followed. 

5.

 

Do not use this apparatus near water - for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a 
wet basement, near a swimming pool, swamp or salivating St. Bernard dog, etc. 

6.

 

Clean only with dry cloth. 

7.

 

Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. - This OWI 
product should be situated so that its location or position does not interfere with its proper ventilation. For 
example, the Component should not be situated on a bed, sofa, rug, or similar surface that may block any 
ventilation openings, or placed in a built-in installation such as a bookcase or cabinet that may impede the 
flow of air through ventilation openings. 

8.

 

Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including 
amplifiers) that produce heat. 

9.

 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider 
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult 
an electrician for replacement of the obsolete outlet.  

10.

 

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and 
the point where they exit the apparatus. 

11.

 

Only use attachment/accessories specified by the manufactures. 

12.

 

Use only with the cart, stand, tripod, bracket or table specified by the manufacturer, or sold 
with the apparatus. When a cart is used, use caution when moving the cart/apparatus 
combination to avoid injury from tip-over.  

 

Summary of Contents for MCRC303

Page 1: ...Installation Instructions Model MCRC303 MEDIA CENTER by OWI Established 1978 OWI Incorporated 17141 Kingsview Ave Carson CA 90746 USA Tel 310 515 1900 www owi inc com Technical Support 310 515 1900 ...

Page 2: ...tub washbowl kitchen sink laundry tub in a wet basement near a swimming pool swamp or salivating St Bernard dog etc 6 Clean only with dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions This OWI product should be situated so that its location or position does not interfere with its proper ventilation For example the Component should not be s...

Page 3: ... induced hearing loss but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a period of time The U S Government s Occupational Safety and Health Administration OSHA has specified the permissible noise level exposures shown in the following chart According to OSHA any exposure in excess of these permissible limits could result in some hearing loss To ensure against...

Page 4: ...ore you cut Be sure that nothing is going to disturb the placement of the INWALL AMPLIFIER Please note that this is a digital amplifier This amplifier is small enough for it to fit into a double gang box and gives off very little heat Important All connections should be made with the power turned OFF Note Strip all wires 3 16 and place the wires in the connector and tighten screw to the right Note...

Page 5: ... s or Sources to the MEDIA CENTER to the other desired input 1 2 or 3 be sure that the jumper red plastic is in the correct Mic or line spot 3 Connect the speaker wires to the SPKR CH1 phoenix connectors SPKR CH 2 Everything from the first MEDIA CENTER will be heard on all the speakers if the slide switch is greater than the off position System is now fully operational Description Specifications 2...

Page 6: ...mailed to OWI Inc within 10 days following the date of purchase Units must be sent to OWI Inc or to the dealer where purchased OWI INCORPORATED Date Purchased _____________________ 17141 Kingsview Ave Model Number _____________________ Carson CA 90746 Serial Number _____________________ Keep this part for your record CUT AND MAIL OWI INCORPORATED 17141 Kingsview Ave Carson CA 90746 LIMITED WARRANT...

Reviews: