TORQUE CONVERTER

RECOMMENDED RUNNING & OVERHAUL SPARE PARTS

FOR C-195-OWI TORQUE CONVERTER

NATIONAL OWI

ITEM

PART NO. 

PART NO. 

DESCRIPTION 

RUNNING 

O/H

PRESSURE CONTROL VALVE 

2232044

1NA1044

Ring, Seal 

       1

   1

2232045

1NA1045

Gasket 

       1

   1

2410022-234

1NA3927

O’ Ring 

       1

   1

GAUGE ASSEMBLY 

2230068

1NA3068

Gauge, Pressure 

       1

   1

2230050

1NA3050

Gauge, Temperature

       1

   1

  

Summary of Contents for C-195-OWI

Page 1: ...RICAN OIL WORKS LTD OWI TORQUE CONVERTER MODEL C 195 OWI SERVICE MANUAL Inter American Oil Works Ltd P O Box 69170 Odessa TX 79769 432 381 5265 oilworksinc oilworksinc com NOT AFFILIATED WITH NATIONAL...

Page 2: ...erator is warned that before performing any internal maintenance work on the torque converter it is necessary to shut down the converter and allow it to cool This precaution must always be observed be...

Page 3: ...ION 2 Start Up 2 Lubrication 3 Oil Change 3 Oil Filter 3 Spin On Filter 3 Breather Filter 4 Strainer and Orifice Assembly 4 Suction Strainer 4 Chain Adjustment 4 Gauges 5 Temperature 5 Oil Pressure 5...

Page 4: ...MUST BE REMOVED MOUNTING TORQUE CONVERTER TO ENGINE 1 Lightly make up torque converter drive ring to engine flywheel and torque converter housing to engine flywheel housing 2 Insert enough shims under...

Page 5: ...cellent oxidation resistance corrosion resistance and containing anti foam inhibitors Viscosity SSU of 150 to 200 at 100o F Viscosity Index in Excess of 100 First Choice Premium Grade Turbine Oils Sec...

Page 6: ...s operated 24 hours per day The elements and cooler should be drained and the sump thoroughly cleaned at this time The elements are drained by removing the two plugs in the drive bell The cooler is dr...

Page 7: ...hen the oil filter is cleaned to avoid clogging If the strainer or orifice is plugged the pressure control valve will not operated properly resulting in sluggish pressure response to loading and unloa...

Page 8: ...e and the type of operation It should never exceed 240o F but can be safely operated up to this point OIL PRESSURE The oil pressure will vary with load At no load it may run as high as 50 psi and will...

Page 9: ...shut down before removing any pipe plugs The oil flow may be checked with a pressure gauge There are two one fourth inch 1 4 pipe plugs on the face of the pressure control valve Remove the plug on th...

Page 10: ...32036 1NA1036 Gasket 1 1 5700021 1NA1916 Chain 1 1 5802101 1NA1959 Link 1 1 2410022 434 1NA1913 O ring 1 1 2232024 1NA1024 Pump 1 1 2410022 328 1NA1914 O ring 2 2 2410022 224 1NA3924 O ring 1 1 SHAFT...