background image

Table of Contents

Cover - Important Safety Information

1

Important Safety Information and

Minimum Clearances to Combustibles

2

Pre-Installation & Preparation Guidelines

3

Important Safety Information

4

Installation Information

Connecting the Gas to the Fire Pit

5

Propane Tank Information

6

Media Placement and Replacement Parts List

Certified Media List / Protective Screen Media Clearance

7

Gem, Mirrored, Crushed Glass and Lava Rock Installation

8

Rock Media Installation

9

Trouble Shooting Guide

10

Warranty Information

11

Operation Instructions

Lighting Instructions

12

Proposition 65 Public Warning

13

Conversion to a Different Gas Type

14

A.

B.

C.

D.

E.

OUTDOOR FIRE PIT - TABLE OF CONTENTS

IMPORTANT SAFETY INFORMATION

READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR FIRE PIT.

If not installed and used correctly per these instructions,

this product can cause serious injury, death, and or property damage and may void the warranty.

CAUTION

:  FIXED PIPING GAS SUPPLY INSTALLATION, AND REPAIRS MUST BE DONE BY

A CERTIFIED PROFESSIONAL TECHNICIAN or LICENSED PLUMBER.

Be sure you understand all safety precautions and warnings contained in this manual.

If you have any questions, please contact O.W. Lee at (800) 776-9533

Clearances to Combustible Construction:

Sidewalls:  60”  (1.5 m) from center of unit (Figure 1)
Ceiling:  60” (1.5 m) from top of unit to ceiling or overhang
Flooring:  0” – Can be installed on deck, slab, floor, etc.

The dimensions shown in Figure 1 are MINIMUM
CLEARANCES to maintain when you install this Outdoor Fire 
Pit.  THERE MUST BE AT LEAST 60” of clearance from the 
center of the unit  to any combustible sidewalls, ceilings, or 
material.

Figure 1

Page 2

CHECK STATE AND LOCAL BUILDING CODES TO DETERMINE IF THE OUTDOOR FIRE PIT IS PERMITTED IN
YOUR LOCALITY BEFORE INSTALLATION.

FOR OUTDOOR USE ONLY.  THIS UNIT MUST BE INSTALLED AT LEAST 60” FROM CENTER OF BURNER TO ANY 
COMBUSTIBLE WALLS, CEILINGS, OR MATERIAL.

WHEN SHUTTING OFF THE UNIT — BE SURE TO TURN THE CONTROL VALVE ON THE FIRE PIT TO THE FULLY OFF 
POSITION ON THE FIRE PIT and CLOSE THE VALVE ON THE PROPANE TANK or NATURAL GAS SUPPLY LINE.

WARNING:  CARBON MONOXIDE POISONING MAY LEAD TO DEATH. 

 DO NOT MODIFY THIS OUTDOOR FIRE PIT

OR ITS CONTROLS, EXCEPT AS PROVIDED FOR IN THIS MANUAL.

IMPROPER INSTALLATION OR USE OF YOUR OUTDOOR FIRE PIT CAN CAUSE SERIOUS INJURY,  DEATH, AND OR 
PROPERTY DAMAGE FROM FIRE, BURNS, EXPLOSIONS OR CARBON MONOXIDE POISONING.

MINIMUM CLEARANCE TO COMBUSTIBLES

NOTE

MINIMUM OF 60” (1.5 m) CLEARANCE ABOVE THE 

OUTDOOR FIRE PIT IF INSTALLED UNDER CEILING OR 

OVERHANG 

60” (1.5 m)

CLEARANCE

FROM CENTER

TO ANY

COMBUSTIBLE

CONSTRUCTION

60” (1.5 m)

CLEARANCE

FROM CENTER

TO ANY 

COMBUSTIBLE

CONSTRUCTION

Summary of Contents for CASUAL FIRESIDE 5110-3050O

Page 1: ...stallation must conform to local building codes or in the absence of local building codes to the National Fuel Gas Code ANSI Z223 1 NFPA 54 International Fuel Gas Code Natural Gas and Propane Installa...

Page 2: ...Combustible Construction Sidewalls 60 1 5 m from center of unit Figure 1 Ceiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab floor etc The dimensions show...

Page 3: ...NSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED F Fixed Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate BTU hr Undue...

Page 4: ...ut into operation if it is evident that the burner is damaged Replacement burner COM0580 manufactured by O W Lee Company 1822 E Francis Street Ontario CA 91761 M DO NOT store any combustible materials...

Page 5: ...rfilling prevention device OPD and with a cylinder connection device compatible with the connection for the appliance 2 Occasional Height Fire Pits Propane Tank Options CONNECTING AN LP GAS CYLINDER P...

Page 6: ...while dissipating Do not check for gas leaks with a match or an open flame Apply soapy water to areas marked X Open cylinder valve If bubble appears close valve and have LP gas service person make nee...

Page 7: ...on the surface and all four sides as shown above Page 7 REPLACEMENT PARTS AND MEDIA ARE AVAILABLE THROUGH YOUR LOCAL DEALER 1 Stainless Steel T Burner 2 Propane Regulator 3 On Off Control Knob 4 Bras...

Page 8: ...Outdoor Fire Pit so that the burner is covered by 1 2 and spread evenly NOTE See Page 7 For Protective Screen Media Clearance See Figure 1 and 2 Figure 1 Pour the first bag of the lava granules media...

Page 9: ...ME AFTER USE YOU MUST MAINTAIN THE LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW M...

Page 10: ...ferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctl...

Page 11: ...ions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any outdoor...

Page 12: ...k valve is closed 2 Wait a minimum of 5 minutes for the gas to clear out OPERATING INSTRUCTIONS We recommend that before you install your Fire Pit you familiarize yourself with the control valve layou...

Page 13: ...for various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemicals...

Page 14: ...k by using a liquid soapy solution on all connections before placing the unit in operation 5 IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO CLEARLY INDICATE TH...

Page 15: ...l qu une caravane une tente une voiture ou la maison 4 Apr s avoir quitt les lieux appelez votre fournisseur de gaz ou le service d incendie DANGER Cet appareil gaz est con u comme un appareil surveil...

Page 16: ...CE MANUEL LIQUIDATION MINIMUM DE COMBUSTIBLES Figure 1 Page 2 PUITS D INCENDIE EXTERIEUR TABLE DES MATIERES INFORMATIONS IMPORTANTES SUR LA S CURIT LIRE CES INSTRUCTIONS ENTI REMENT AVANT D INSTALLER...

Page 17: ...ajustement de l entr e est de 127 mm 3 5 pouces de colonne d eau WC Water Column et la pression maximale d admission est de 254 mm 10 pouces WC POUR LE PROPANE La pression minimale d admission du gaz...

Page 18: ...ISSEMENT NE PAS laisser en fonctionnement sans surveillance AVERTISSEMENT Une installation un r glage une modification un entretien ou une maintenance incorrects peuvent causer des blessures ou des do...

Page 19: ...op plein OPD r pertori et d un dispositif de connexion de bouteille compatible avec le raccordement de l appareil 3 Assurez vous que l appareil n est PAS utilis et fermez le robinet de gaz au robinet...

Page 20: ...ne fuient pas avant d allumer l appareil Le contact avec le liquide contenu dans la bouteille provoquera des br lures de la peau dues au gel Ne laissez pas les enfants alt rer ou jouer avec le cylind...

Page 21: ...gaz naturel n 9 cran de protection 09 n 10 Thermocouple 10 n 11 Ensemble de verres galets Taille 3 4 1 2 9 19mm n 12 Ensemble de vitre coupe feu n Taille 1 2 3 4 12 20 mm n 13 Trousse de vitre miroir...

Page 22: ...TS EN VERRE GEM MIROIR ET BROY Versez le support en miroir la pierre pr cieuse ou le verre pil dans le Br leur de foyer ext rieur afin que le br leur soit couvert REMARQUE Voir page 7 pour le d gageme...

Page 23: ...provoquer une expansion des gaz pi g s ou de l humidit et provoquer un clatement et un lancement pourrait causer des blessures ou des dommages mat riels Laissez les granules de lave s cher compl temen...

Page 24: ...ans le venturi et orifices des trous pour d gager le passage libre des toiles d araign es ou d autres d bris Assurez vous de tout remettre correctement lorsque vous avez termin pour le fonctionnement...

Page 25: ...ant Parties Pit Fire O W Lee offre une garantie limit e de deux 2 ans sur tous les composants du br leur en utilisation normale et appropri e entretien OW Lee sera l usine de r parer ou de remplacer t...

Page 26: ...ande du foyer et la soupape du r servoir de propane sont ferm es 2 Attendez au moins 5 minutes que le gaz se vide MODE D EMPLOI Nous vous recommandons de vous familiariser avec le sch ma de la vanne d...

Page 27: ...ue r pertori de la Proposition 65 La combustion de propane dans des appareils tels que des po les ou des syst mes de chauffage et des v hicules utilisant du propane cr e des produits chimiques nocifs...

Page 28: ...ce que les orifices d admission d air soient ferm s Figure 2 Pour le gaz propane retirez l obturateur d air de fa on ce que les orifices d admission d air soient ouverts Figure 1 Une fois que l unit e...

Reviews: