WARNING

WHEN CONNECTING FOR USE:

Use only in compliance with applicable codes.

Read and follow the manufacturer's instructions.

Be sure the regulator vent is not pointing up.

Turn off all of the valves on the appliance.

Do not use, store or transport cylinder where it 
would be exposed to high temperatures.  Relief 
valve may open allowing a large amount of 
flammable gas to escape.

When transporting, keep cylinder secured in an 
upright position with cylinder valve turned off.

DO NOT REMOVE, DEFACE, OR OBLITERATE THIS LABEL

*EXCEPT AS AUTHORIZED BY ANSI/NFPA 58.

DANGER!

  Do not store a spare LP cylinder under or near a barbeque, or other heat sources.

Never fill an LP cylinder beyond 80% full, a fire causing death or serious injury may occur.

Page 6

LP-gas is heavier than air and may settle in low 
places while dissipating.

Do not check for gas leaks with a match or an open 
flame.  Apply soapy water to areas marked "X".  
Open cylinder valve. If bubble appears, close valve 
and have LP-gas service person make needed 
repairs. Also check appliance valves and 
connections to make sure they do not leak before 
lighting appliance,

Contact with the liquid contents of the cylinder 
will cause freeze burns to the skin

Do not allow children to tamper or play with 
cylinder.

Light appliance(s) following manufacturer's 
instructions.

When not connected for use, keep cylinder valve 
turned off.  Self contained appliances shall be 
limited to a cylinder of 30 lb. capacity or less.

When appliance is not in use, keep the cylinder 
valve closed.

DANGER 

- FLAMMABLE GAS UNDER PRESSURE

LEAKING LP-GAS MAY CAUSE A FIRE OR EXPLOSION IF IGNITED

CAUSING SERIOUS BODILY INJURY OR DEATH.

CONTACT LP GAS SUPPLIER FOR REPAIRS, OR DISPOSAL OF

THIS CYLINDER OR UNUSED LP-GAS.

WARNING

 - FOR OUTDOOR USE ONLY*

DO NOT USE OR STORE CYLINDER IN A BUILDING, GARAGE

OR ENCLOSED AREA.

Know the odor of LP-gas.  If you hear, see or smell 
leaking LP-gas, immediately get everyone away 
from the cylinder and call the Fire Department.  Do 
not attempt repairs.

Consult manufacturer's instructions concerning 
the cylinder connection provided with your 

Caution your LP-gas supplier to

Be certain cylinder is purged of trapped air prior to 
first filling.
Be certain not to over fill the cylinder.
Be certain cylinder requalification date is checked.

Summary of Contents for 5110-3050C

Page 1: ...NSI Z21 97 2017 CSA 2 41 2017 CGA 2 17 M91 R2017 The link below will take you to the Owners Manual and Operating Instructions in French where you can download a copy S lectionnez le lien ci dessous po...

Page 2: ...Y THIS UNIT MUST BE INSTALLED AT LEAST 60 FROM CENTER OF BURNER TO ANY COMBUSTIBLE WALLS CEILINGS OR MATERIAL WHEN SHUTTING OFF THE UNIT BE SURE TO TURN THE CONTROL VALVE ON THE FIRE PIT TO THE FULLY...

Page 3: ...pit and it must be closed during any pressure testing of the system at test pressures in excess of psi 3 5kPa C CHECK GAS TYPE Natural Gas or Propane The gas supply you intend to use may not be the s...

Page 4: ...near the appliance O DO NOT use this appliance if any part of it has been under water Call a qualified service technician to inspect the appliance and to replace any part of the control system and any...

Page 5: ...ing put into operation if there is evidence of excessive abrasion or wear or if the hose is damaged The replacement hose must be specified by the manufacturer Page 5 1 2 The LP Gas Cylinder s to be us...

Page 6: ...ves and connections to make sure they do not leak before lighting appliance Contact with the liquid contents of the cylinder will cause freeze burns to the skin Do not allow children to tamper or play...

Page 7: ...9 19mm 12 Crushed Fire Glass Kit Size 1 2 3 4 12 20 mm 13 Mirrored Glass Kit Size 1 4 6 35mm 14 Lava Granules 3 8 15 Ceramic Rock Kit with Lava Granules PROTECTIVE SCREEN MEDIA PLACEMENT Media placem...

Page 8: ...e to expand and cause a pop and launch outside of the fire pit which could cause injury or property damage Allow lava granules to completely dry after getting wet rained on or hosed off before lightin...

Page 9: ...PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING CAUTION Lava gr...

Page 10: ...ferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctl...

Page 11: ...ions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any outdoor...

Page 12: ...k valve is closed 2 Wait a minimum of 5 minutes for the gas to clear out OPERATING INSTRUCTIONS We recommend that before you install your Fire Pit you familiarize yourself with the control valve layou...

Page 13: ...for various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemicals...

Page 14: ...nd replace it with the proper sized one for your gas requirement Propane requires the smaller orifice 4 If you are converting from propane LP gas to natural gas install the air shutter sleeve so that...

Page 15: ...ne une tente une voiture ou la maison 4 Apr s avoir quitt les lieux appelez votre fournisseur de gaz ou le service d incendie DANGER Cet appareil gaz est con u comme un appareil surveill Les adultes d...

Page 16: ...ILISATION INCORRECTE OU UTILIS E DE VOTRE PUITS D INCENDIE EXT RIEUR PEUT CAUSER DES BLESSURES GRAVES LA MORT OU DES DOMMAGES LA PROPRI T EN CAS D INCENDIE DE BR LURES D EXPLOSIONS OU D EMPOISONNEMENT...

Page 17: ...rie du gaz doit tre dimensionn de sorte fournir la pression minimale d admission au d bit maximum BTU hr Une perte excessive de pression se produira si le tuyau est trop petit ou trop long G Casual Fi...

Page 18: ...nstallation et les r parations doivent tre effectu es par un technicien qualifi L appareil doit tre inspect avant utilisation et au moins une fois par an par un technicien qualifi Un nettoyage plus fr...

Page 19: ...vent pas tre entrepos s dans un b timent un garage ou un autre espace clos 6 La bouteille de gaz GPL doit reposer sur la base inf rieure de la bouteille con ue pour permettre un retrait appropri de la...

Page 20: ...ne fuient pas avant d allumer l appareil Le contact avec le liquide contenu dans la bouteille provoquera des br lures de la peau dues au gel Ne laissez pas les enfants alt rer ou jouer avec le cylind...

Page 21: ...gaz naturel n 9 cran de protection 09 n 10 Thermocouple 10 n 11 Ensemble de verres galets Taille 3 4 1 2 9 19mm n 12 Ensemble de vitre coupe feu n Taille 1 2 3 4 12 20 mm n 13 Trousse de vitre miroir...

Page 22: ...TS EN VERRE GEM MIROIR ET BROY Versez le support en miroir la pierre pr cieuse ou le verre pil dans le Br leur de foyer ext rieur afin que le br leur soit couvert REMARQUE Voir page 7 pour le d gageme...

Page 23: ...provoquer une expansion des gaz pi g s ou de l humidit et provoquer un clatement et un lancement pourrait causer des blessures ou des dommages mat riels Laissez les granules de lave s cher compl temen...

Page 24: ...ans le venturi et orifices des trous pour d gager le passage libre des toiles d araign es ou d autres d bris Assurez vous de tout remettre correctement lorsque vous avez termin pour le fonctionnement...

Page 25: ...ant Parties Pit Fire O W Lee offre une garantie limit e de deux 2 ans sur tous les composants du br leur en utilisation normale et appropri e entretien OW Lee sera l usine de r parer ou de remplacer t...

Page 26: ...ande du foyer et la soupape du r servoir de propane sont ferm es 2 Attendez au moins 5 minutes que le gaz se vide MODE D EMPLOI Nous vous recommandons de vous familiariser avec le sch ma de la vanne d...

Page 27: ...ue r pertori de la Proposition 65 La combustion de propane dans des appareils tels que des po les ou des syst mes de chauffage et des v hicules utilisant du propane cr e des produits chimiques nocifs...

Page 28: ...ce que les orifices d admission d air soient ferm s Figure 2 Pour le gaz propane retirez l obturateur d air de fa on ce que les orifices d admission d air soient ouverts Figure 1 Une fois que l unit e...