The SCD Dot is only illuminated if the LTO tape drive is both in Maintenance mode AND
there is a drive dump available.
Status Lights During Power-on or Reset
During power-on, or a drive reset, the drive front panel displays drive progress as follows:
1.
SCD displays random segments (no lights ON).
2.
SCD displays random segments (Ready light ON).
3.
SCD displays random segments (Fault light ON).
4.
SCD displays
8
(Ready, Fault, Encryption, and SCD dot lights are all ON).
5.
SCD goes blank (with Ready light ON) after a successful power-on or reset.
If an error is detected during the power-on or reset, the tape drive posts an error code to the
SCD. To determine the error, locate the code in the
“Error Codes Table” on page 62
.
Eject Button
The Eject button is used to perform the following functions:
Function
How to Initiate the Function
Rewind the tape into the
cartridge and eject the
cartridge from the tape drive
Press the Eject button once.
The Ready light flashes green while the tape drive is rewinding and
unloading.
NOTE: During a rewind and eject operation, the tape drive does not
accept SCSI or Fibre Channel commands from the server.
Place the tape drive in
Maintenance mode
Ensure that the tape drive is unloaded. Then, press the Eject button three
times within two seconds. You are in Maintenance mode when the Ready
light flashes and
0
appears in the SCD.
NOTE: While in Maintenance mode, the tape drive does not accept SCSI
or Fibre Channel interface commands.
If you attempt to enter Maintenance mode with a cartridge in the drive, the
drive rewinds and ejects the cartridge. Remove the cartridge and repeat
the steps for entering Maintenance mode.
Scroll through the
maintenance functions
While in Maintenance mode, push the Eject button once per second to
increment the display characters by one. When you reach the character of
the diagnostic or maintenance function that you want (see
), press and hold the Eject button for three seconds.
Exit Maintenance mode
Press the Eject button once per second until
0
displays. Then press and
hold the Eject button for 3 seconds. Maintenance mode is exited when the