background image

13

5 Construction and function

5.1 Summary and functional description

The  boiler  connection  system  RTA  is  available  with
temperature controller 40-70°C or 50-80°C (only “Re-
gumat RTA-180”).
Recommended  control  range  temperature  controller
40-70°C: Position 4-5
Recommended  control  range  temperature  controller
50-80°C: Position 2-3
The  recommendations  of  the  boiler  manufacturers
must be observed! 
A return temperature of about 55°C is achieved with
the a.m. control range of the corresponding tempera-
ture controller.
The boiler connection system allows the connection
of the heating system/storage cylinder to the solid fuel
boiler. A three-way mixing valve integrated in the return
ensures that uncritical boiler temperatures are reached
quickly.
During start-up, the boiler is short circuited. Hot flow
water is directed to the boiler return via the bypass.
Having reached the set return temperature (normally
55°C),  the  mixing  valve  opens  the  heating  or  buffer
storage cylinder circuit and prevents the return tem-
perature from dropping below the value set at the tem-
perature controller.

Example of installation:

6 Installation

Installation, initial operation, maintenance and repairs
have to be carried out by authorised and qualified tra-
desmen  (EN  5011  part  1  and  VDE  1000  part  10  for
work on electrical installations).

Warning  advice  under  paragraph  2  (safety  notes)
must be observed!

The pipework has to be flushed thoroughly before in-
stalling the boiler connection system. It can be installed
in any position (horizontal, inclined or vertical, in as-
cending or descending sections) provided that the di-
rection of flow conforms to the arrow on the valve.

The product group is supplied pre-assembled.

During operation, the slot for opening the check valve
must be in horizontal position. 

Illustr.  5  Installation  of  a  “Regumat“  between  a  solid
fuel boiler and a buffer storage cylinder

Illustr. 6 Position of the check valve

The example of installation (Illustr. 5) is only a sche-
matic illustration and shows a possible hydronic
circuitry. The safety components must be carried
out  in  accordance  with  the  valid  standards,  ap-
proved rules of technology and local regulations.

Before starting work, make sure that the pipework
and the components have cooled down and been
drained!
Before  starting  work,  disconnect  electrical  com-
ponents (controllers, pumps etc.) from power.

5.2 Markings

– CE marking on the pump:

CE marking

– Information on the body:

OV

Oventrop

DN

Size

After installation, check all installation points for
leaks.

ATTENTION

WARNING

!

!

Summary of Contents for Regumat RTA-130

Page 1: ...men Mitgeltende Unterlagen Anleitungen aller Anlagen komponenten insbesondere die Bedienungsanleitung der Umwälzpumpe sowie geltende technische Regeln sind einzuhalten Inhalt 1 Allgemeine Hinweise 1 2 Sicherheitshinweise 2 3 Transport Lagerung und Verpackung 2 4 Technische Daten 2 5 Aufbau und Funktion 6 6 Einbau 6 7 Betrieb 7 8 Zubehör 7 9 Wartung und Pflege 7 10 Gewährleistung 7 Technische Änder...

Page 2: ...stellbar sind Warensendung nur unter Vorbehalt annehmen Rekla mation einleiten Dabei Reklamationsfristen beachten 3 3 Verpackung Sämtliches Verpackungsmaterial ist umweltgerecht zu entsorgen 4 Technische Daten 4 1 Varianten Das Heizkessel Anbindesystem Regumat RTA ist in folgenden Ausführungen erhältlich Regumat RTA 130 VR DN25 mit Standardisolierung Regumat RTA 130 VL DN25 mit Standardisolierung ...

Page 3: ...rdisolierung Vorlauf auf der rechten Seite Kessel ist oberhalb der Station angeordnet Abb 4 1 Regumat RTA 130 VR DN25 mit Standardisolierung Vorlauf auf der rechten Seite Kessel ist unterhalb der Station angeordnet Rücklauf vom HK Pufferspeicher Vorlauf zum HK Pufferspeicher Rücklauf zum Kessel min Temperatur 55 C Vorlauf vom Kessel Vorlauf vom Kessel Rücklauf zum Kessel min Temperatur 55 C Rückla...

Page 4: ...180 DN25 mit Standardisolierung Vorlauf auf der rechten Seite Kessel ist unterhalb der Station angeordnet Rücklauf vom HK Pufferspeicher Vorlauf zum HK Pufferspeicher Rücklauf zum Kessel min Temperatur 55 C Vorlauf vom Kessel Abb 4 6 Regumat RTA 180 DN32 mit Standardisolierung Vorlauf auf der rechten Seite Kessel ist unterhalb der Station angeordnet Rücklauf vom HK Pufferspeicher Vorlauf zum HK Pu...

Page 5: ...ussdiagramm Durchflussdiagramm Regumat RTA 130 180 DN 25 Druckverlust p mbar Druckverlust p Pascal Durchfluss V l h Druckverlust p mbar Druckverlust p Pascal Durchfluss V l h Durchflussdiagramm Regumat RTA 180 DN 32 ...

Page 6: ...hlener Einstellbereich Temperaturregler 40 70 C Stellung 4 5 Empfohlener Einstellbereich Temperaturregler 50 80 C Stellung 2 3 Die Empfehlungen der Heizkesselhersteller sind zu be achten Mit dem oben genannten empfohlenen Einstellbereich des jeweiligen Temperaturreglers wird eine Rücklauf temperatur von ca 55 C erreicht Das Heizkessel Anbindesystem ermöglicht den An schluss des Heizsystems Speiche...

Page 7: ...h eine Rück lauftemperatur von 55 C einstellt Von Ziffer zu Ziffer beträgt die Temperaturänderung 5 K Verstellbereich 30 K Kennzeichnung des Handrades 1 7 7 Betrieb 7 1 Entlüftung der Anlage Vor der Inbetriebnahme muss die Anlage aufgefüllt und entlüftet werden Dabei sind die zulässigen Be triebsdrücke zu berücksichtigen 7 2 Korrekturfaktoren für Wasser Glykol Gemische Die Korrekturfaktoren der Fr...

Page 8: ...e installation and operating instructions serve the trained tradesman to install the boiler connection sys tem professionally and to put it into operation Other valid documents manuals of all system com ponents especially the operating instructions of the circulation pump as well as valid technical rules must be observed Content 1 General information 9 2 Safety notes 10 3 Transport storage and pac...

Page 9: ...ventrop offers the following models Regumat RTA 130 VR DN25 with standard insulation Regumat RTA 130 VL DN25 with standard insulation Regumat RTA 130 TOP DN25 with standard insulation Regumat RTA 180 DN25 with universal insulation Regumat RTA 180 DN25 with standard insulation Regumat RTA 180 DN32 with standard insulation 4 2 Performance data Dimension DN25 DN32 Max operating pressure 10 bar Max op...

Page 10: ...3 Regumat RTA 130 TOP DN25 with standard insulation Supply on right hand side Boiler is located above the Regumat Illustr 4 1 Regumat RTA 130 VR DN25 with standard insulation Supply on right hand side Boiler is located below the Regumat Supply from boiler Return to boiler Min temperature 55 C Return to boiler Min temperature 55 C Supply from boiler Return from radiator buffer storage cylinder Supp...

Page 11: ...on Supply on right hand side Boiler is located below the Regumat Return from radiator buffer storage cylinder Supply to radiator buffer storage cylinder Return to boiler Min temperature 55 C Supply from boiler Return from radiator buffer storage cylinder Supply to radiator buffer storage cylinder Return to boiler Min temperature 55 C Supply from boiler Return from radiator buffer storage cylinder ...

Page 12: ...4 5 Flow charts Flow chart Regumat RTA 130 180 DN 25 Pressure loss p mbar Pressure loss p Pascal Flow rate V l s Pressure loss p mbar Pressure loss p Pascal Flow rate V l s Flow chart Regumat RTA 180 DN 25 ...

Page 13: ...ntenance and repairs have to be carried out by authorised and qualified tra desmen EN 5011 part 1 and VDE 1000 part 10 for work on electrical installations Warning advice under paragraph 2 safety notes must be observed The pipework has to be flushed thoroughly before in stalling the boiler connection system It can be installed in any position horizontal inclined or vertical in as cending or descen...

Page 14: ...er so that a return temperature of 55 C is reached The temperature modification between the figures amounts to 5 K setting range 30 K graduation on handwheel 1 7 7 Operation 7 1 Deaeration of the system Before initial operation the installation must be filled and bled with due consideration of the permissible operating pressures 7 2 Correction factors for water and glycol mixtu res The correction ...

Page 15: ... d installation et d uti lisation Cette notice d installation et d utilisation a pour but d aider le professionnel à installer et mettre en service le système de raccordement pour chaudières dans les règles de l art Autres documents de référence Les notices de tous les composants du système surtout la notice d in stallation du circulateur ainsi que les règles techniques en vigueur sont à respecter...

Page 16: ...r l absence de dommages dus au transport Si des dommages ou d autres défauts sont constatés n accepter la marchandise que sous réserve Emettre une réclamation en respectant les délais applicables 3 3 Emballage Le matériel d emballage est à éliminer dans le respect de l environnement 4 Données techniques 4 1 Modèles Oventrop propose les modèles suivants Regumat RTA 130 VR DN25 avec isolation standa...

Page 17: ...4 1 Regumat RTA 130 VR DN25 avec isolation standard Aller à droite Chaudière montée en dessous de la station Retour venant du radiateur ballon tampon Aller vers le radiateur ballon tampon Retour vers la chaudière Température min 55 C Aller venant de la chaudière Aller venant de la chadière Retoure vers la chaudière Température min 55 C Retoure vers la chadière Température min 55 C Aller venant de ...

Page 18: ...re montée en dessous de la station Retoure venant du radiateur ballon tampon Aller vers le radiateur ballon tampon Retoure vers la chaudière Température min 55 C Aller venant de la chaudière Retoure venant du radiateur ballon tampon Aller vers le radiateur ballon tampon Retoure vers la chaudière Température min 55 C Aller venant de la chaudière Retoure venant du radiateur ballon tampon Aller vers ...

Page 19: ...es de débit Diagramme de débit Regumat RTA 130 180 DN 25 Perte de charge p mbar Perte de charge p Pascal Debit V l h Perte de charge p mbar Perte de charge p Pascal Debit V l h Diagramme de débit Regumat RTA 180 DN 32 ...

Page 20: ...n et les réparations doivent être effectués par des profes sionnels qualifiés professionnel du chauffage entre prise d installation agréée EN 5011 partie1 et VDE 1000 partie 10 pour travaux aux installations électri ques Les signalements de danger sous paragraphe 2 consignes de sécurité doivent être observés Avant le montage du système de raccordement pour chaudières dans la tuyauterie celle ci do...

Page 21: ...mpérature de telle manière qu une température de retour de 55 C soit atteinte D un chiffre à l autre la modification de la tempéra ture est de 5 K plage de réglage 30 K graduation sur la poignée 1 7 7 Opération 7 1 Purge de l installation L installation doit être remplie et purgée avant la mise en service en respectant les pressions de service admissibles 7 2 Facteurs de correction pour mélanges e...

Page 22: ...nzionamento Queste istruzioni d installazione e di funzionamento servono al personale competente per installare il Gruppo di collegamento caldaia e metterlo in funzione in modo professionale Osservare i documenti condivisi le istruzioni di tutti i componenti dell impianto e in particolare le istruzioni d uso della pompa di circolazione come anche tutte le normative tecniche in vigore Incide 1 Info...

Page 23: ...e Se sono rilevabili danni di questo tipo o di altra natura accettare la fornitura della merce soltanto con riserva Inoltrare il reclamo e osservare i termini dello stesso 3 3 Imballaggio Tutto il materiale d imballaggio deve essere smaltito nel rispetto dell ambiente 4 Dati tecnici 4 1 Varianti Il Gruppo di collegamento caldaia Regumat RTA è disponibile nelle seguenti versioni Regumat RTA 130 VR ...

Page 24: ...posizionata sopra della stazione Fig 4 1 Regumat RTA 130 VR DN25 con isolamento standard Mandata sul lato destro Caldaia posizionata sotto alla stazione Ritorno dal circuito riscaldamento accumulo Mandata al circuito riscaldamento accumulo Ritorno alla caldaia temperatura min 55 C Mandata dalla caldaia Mandata dalla caldaia Ritorno alla caldaia temperatura min 55 C Ritorno alla caldaia temperatura...

Page 25: ...on isolamento standard Mandata sul lato destro Caldaia posizionata sotto alla stazione Ritorno dal circuito riscaldamento accumulo Mandata al circuito riscaldamento accumulo Ritorno alla caldaia temperatura min 55 C Mandata dalla caldaia Fig 4 6 Regumat RTA 180 DN32 con isolamento standard Mandata sul lato destro Caldaia posizionata sotto alla stazione Ritorno dal circuito riscaldamento accumulo M...

Page 26: ...iagramma di flusso Regumat RTA 130 180 DN 25 Perdita di pressione p mbar Perdita di pressione p Pascal Portata V l h Perdita di pressione p mbar Perdita di pressione p Pascal Portata V l h Diagramma di flusso Regumat RTA 180 DN 32 ...

Page 27: ...liato regolatore tempe ratura 40 70 C posizione 4 5 Campo di regolazione consigliato regolatore tempe ratura 50 80 C posizione 2 3 Seguire le istruzioni della casa costruttrice di caldaie da riscaldamento Con il campo di regolazione sopra consigliato del re lativo regolatore di temperatura si raggiunge una tem peratura di ritorno di circa 55 C Il Gruppo di collegamento caldaia permette l allaccia ...

Page 28: ...le che si rag giunga una temperatura di ritorno di 55 C Di cifra in cifra la modifica della temperatura è 5 K max campo di regolazione 30 K marcatura volantino 1 7 7 Funzionamento 7 1 Sfiato dell impianto Prima della messa in funzione l impianto deve essere caricato e poi sfiatato Durante questa operazione ri spettare le pressioni d esercizio consentite 7 2 Fattori correttivi per miscele acqua gli...

Reviews: