4. SAFETY MEASURES
4.1. SAUM6 device satisfies 0 protection range according to the allUnion State Standard
12.2.007.075.
4.2. “The rules of exploitation user’s electrical installations”, “The rules of protection of labour
using user’s electrical installations” and demands of the allUnion State Standard 12.3.01980 are
obligatory to keep while using and servicing the device.
4.3. Any connections to the device and its servicing are possible to do only if the power of the
device and actuators is off.
4.4. Work with the device is possible only after reading this passport and user manual.
5. MOUNTING AND PREPARATION FOR WORK
5.1. Level sensors mounting
5.1.1. Install level sensors on the marks, assigned by the process conditions.
5.1.2. After mounting conductometric sondes check up if there is any bridging of their
electrodes or bridging of electrodes and metal reservoir body.
5.2. External connections mounting
5.2.1. Prepare and install cables to connect SAUM6 device with level sensors, external
equipment and power supply unit 220 VAC, 50 Hz. It is recommended to use cables with copper multi
stranded cable cords. Cable cord’s ends should be thoroughly stripped before connection. Cable
cord’s profiles must be not more than 0.75 mm
2
.