background image

13

V1.47

ing on a monthly basis. Periodic cleaning will ensure longevity, and crisp output.

To clean the fixture:

1. 

Disconnect the fixture from power and allow it to cool for at least 10 minutes.

2. 

Vacuum or gently blow away dust and loose particles from the outside of the fixture with low-pressure 

compressed air.

3.  Clean the surfaces by wiping gently with a soft, clean lint-free cloth moistened with a weak detergent 

solution. Do not rub glass surfaces hard: lift particles off with a soft repeated press. Dry with a soft, 

clean, lint-free cloth or low-pressure compressed air. Remove stuck particles with an unscented tis-
sue or cotton swab moistened with glass cleaner or distilled water.

4. 

Check that the fixture is dry before reapplying power.

Fuse Replacement

This fuse is located in a fuseholder next to the MAINS OUT socket on the connections panel.
To replace a fuse:

1. 

Disconnect the fixture from power and allow it to cool for at least 10 minutes.

2. 

Unscrew the cap of the fuseholder and remove the fuse. Replace with a fuse of the same size and 

rating only.

3.  Reinstall the fuseholder cap before reapplying power.

Troubleshooting

Listed below are a few common problems that you may encounter, with solutions.

The fixture does not work, no light

• 

Check the connection of power and main fuse. Be sure the external fuse has not blown.

• 

Measure the mains voltage on the main connector.

T

echnical specifications

Model

Honor 250T Zoom

Power supply:

AC100-240V, 50/60Hz

Light source:

500W COB LED (250W warm white + 250W cold white)

Color temperature: 

2700K ~ 5600K tunable

Color Rendition:

CRI 97, R9≥90, TLCI 98(2700K)

Zoom scale:

18°-38° manually

Power connection: 

PowerCON in&out

Fuse:

F5A, 250V

Maximum power linking:

6 units

Signal connection:

3-pin XLR in & out

DMX channels:

2/3

Control mode: 

RDM, DMX, Rotary

Housing:

Colour black, ABS+PC

Size:

745 x 294 x 294mm(29.3 x 11.6 x 11.6in)

Package(carton):

790 x 350 x 360mm(31.1 x 13.8 x 14.2in)

N.W.:

8.7kg(19.2lb)

G.W.:

11.5kg(25.4lb)

Enviroment:

IP20

Summary of Contents for Honor 250T Zoom

Page 1: ...USER MANUAL HONOR 250T ZOOM Profile Spot Zoom 250W tunable...

Page 2: ...with a safety cable 6 DMX 512 connection connection between fixtures 6 Power connection 7 Operation 7 Control Menu Map 7 Control menu 8 Main Menu 9 Addressing 9 Universal DMX Control 10 RDM control 1...

Page 3: ...ing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operation and ma...

Page 4: ...tton Enter button Dmx signal indicator Power indicator Handle Rotary button Dmx out Dmx in Fuse Power out Power in On off switch LCD display Yoke Shutters Gobo holder slot Iris slot Focus knob Yoke lo...

Page 5: ...l over If you install the fixture in a location where it may cause injury or damage if it falls secure it as directed be low with a securely anchored safety cable that will hold the fixture if the pri...

Page 6: ...h the DMX input of the first fixture in the DMX chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Building a serial DMX chain Connect the DMX output of...

Page 7: ...own Live L Blue Neutral N Yellow green Earth Ground Operation The Honor 250T Zoom zoom can operate in three different modes In each mode you can run the fixture as a stand alone fixture or in a master...

Page 8: ...Hold On Off Run if signal cut RDM On Off RDM function on off Screen Timeout 30S Display shut off time Never Screen Brightness 25 100 Display brightness Dimming Freq 1 20KHz Dimmer frequency setting 1...

Page 9: ...each fixture individually If you set the same address all the units will start to listen to the same control signal from the same channel number In other words changing the settings of one channel wil...

Page 10: ...function you can set the DMX address of your fixtures remotely This is especially useful when the device is installed in a remote area Each Honor 250T Zoom has a factory set RDM UID unique identificat...

Page 11: ...button to enter the main menu 2 Press the UP or DOWN button to select Dimmer menu and press ENTER 3 Press DOWN menu and select Mode sub menu 4 Select disired dimmer mode Custom dimmer curves 1 Press t...

Page 12: ...mer CH2 Cold white 000 255 0 100 cold white dimmer 3 Channels Mode Function Function Control CH1 Dimmer 000 255 0 100 master dimmer CH2 Warm white 000 255 0 100 warm white dimmer CH3 Cold white 000 25...

Page 13: ...ct the fixture from power and allow it to cool for at least 10 minutes 2 Unscrew the cap of the fuseholder and remove the fuse Replace with a fuse of the same size and rating only 3 Reinstall the fuse...

Page 14: ...14 V1 47 Please note All information is subject to change without prior notice 05 11 2019...

Page 15: ...15 V1 47...

Page 16: ...16 V1 47...

Reviews: