Ovation C-805FC User Manual Download Page 6

Page 3 of 28

 B

EFORE 

Y

OU 

B

EGIN

Ovation C-805FC User Manual Rev. 3

Safety Notes

Read all the following safety notes before working with this product. These notes contain important 
information about the installation, usage, and maintenance of this product.

Personal Safety

Avoid direct eye exposure to the light source while the product is on.

Always disconnect the product from the power source before cleaning or replacing the fuse.

Always connect the product to a grounded circuit to avoid the risk of electrocution.

Do not touch the product’s housing when operating because it may be very hot.

Mounting and Rigging

This product is not intended for permanent installation.

This product is for indoor use only! To prevent risk of fire or shock, do not expose this product to 
rain or moisture. (IP20)

CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to 
warm humid ballroom) condensation may form on the internal electronics of the product. To avoid 
causing a failure, allow product to fully acclimate to the surrounding environment before connecting 
it to power.

Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent 
surfaces.

Make sure there are no flammable materials close to this product while it is operating.

When hanging this product, always secure to a fastening device using a safety cable.

Never carry the product by the power cord.

Power and Wiring

Make sure the power cord is not crimped or damaged.

Always make sure you are connecting this product to the proper voltage in accordance with the 
specifications in this manual or on the product’s specification label.

To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely 
disconnect the product from power via breaker or by unplugging it.

Never connect this product to a dimmer pack or rheostat.

Make sure to replace the fuse with another of the same type and rating.

Never disconnect this product by pulling or tugging on the power cable.

Operation

Do not operate this product if there is damage on the housing, lenses, or cables. Have the damaged 
parts replaced by an authorized technician at once.

Do not cover the ventilation slots when operating to avoid internal overheating.

The maximum ambient temperature is 113 °F (45 °C). Do not operate the product at higher temperatures.

In the event of a serious operation problem, stop using this product immediately!

Expected LED Lifespan

LEDs gradually decline in brightness over time, primarily because of heat. LEDs that are arranged in 
clusters experience higher operating temperatures than single LEDs. For this reason, operating clustered 
LEDs at their fullest intensity significantly reduces the LEDs’ lifespan. Under normal conditions, this 
lifespan is 40,000 to 50,000 hours. If extending this lifespan is vital, lower the operating temperature by 
improving the ventilation around the product, thus reducing the ambient temperature. In addition, limiting 
the overall projection intensity may extend the LEDs’ lifespan.

This product contains no user-serviceable parts. Any reference to servicing in 
this User Manual will only apply to properly trained, certified technicians. Do not 
open the housing or attempt any repairs.

All applicable local codes and regulations apply to proper installation of this 
product.

If your Chauvet product requires service, contact Chauvet Technical Support. 

!

Summary of Contents for C-805FC

Page 1: ...User Manual...

Page 2: ...xpected LED Lifespan 3 3 Introduction 4 Description 4 Features 4 Product Overview 5 Product Dimensions 6 4 Setup 7 AC Power 7 AC Plug 7 Power Linking 7 DMX Linking 7 DMX Personalities 7 Master Slave C...

Page 3: ...files 22 LED Frequency 22 Back Light 23 Display Orientation 23 Fixture Hours Software Version 23 RDM Remote Device Management 23 Device Name 23 Factory Reset 23 Preset Color Temperature Chart 23 Virtu...

Page 4: ...y other purpose without written consent from Chauvet Document Printing For best results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm config...

Page 5: ...2 Gel Frames 5 32 x 9 65 in 135 x 245 mm 2 Omega Brackets with mounting hardware Warranty Card Quick Reference Guide Convention Meaning 1 512 A range of values 50 60 A set of values of which only one...

Page 6: ...s manual or on the product s specification label To eliminate unnecessary wear and improve its lifespan during periods of non use completely disconnect the product from power via breaker or by unplugg...

Page 7: ...ividually adjustable heads offer great coverage Features 3 4 5 6 8 9 10 15 17 19 20 or 31 channel full color RGBAL LED wash product Static color mixing without DMX control 16 bit dimming of master dim...

Page 8: ...28 INTRODUCTION Ovation C 805FC User Manual Rev 3 Product Overview Display Menu Buttons 3 and 5 pin DMX Output powerCon Output Adjustable Heads 3 and 5 pin DMX Input Fuse Holder Adjustment Knobs power...

Page 9: ...Page 6 of 28 Ovation C 805FC User Manual Rev 3 INTRODUCTION Product Dimensions 12 2 in 310 mm 11 7 in 298 mm 15 3 in 390 mm...

Page 10: ...sing other DMX compatible products with this product you can control each individually with a single DMX controller DMX Personalities The Ovation C 805FC uses a 3 or 5 pin DMX data connection for the...

Page 11: ...recommends using the following general guidelines when mounting this product Before deciding on a location for the product make sure there is easy access to the product for maintenance and programming...

Page 12: ...use as a floor stand You must supply the mounting clamps Make sure the clamps are capable of supporting the weight of this product Use at least one mounting point per product For the CHAUVET Professio...

Page 13: ...first programming level for that option To select an option or value within the current programming level press UP or DOWN until the option shows on the display Press ENTER to select In this case if t...

Page 14: ...CH 10 channel 16 bit RGBAL RGBAL FULL 17CH 17 channel 16 bit dimmer 16 bit RGBAL virtual color wheel color temperature strobe color macros dimmer mode 2 Cell RGB 6CH 6 channel RGB per cell RGBA 8CH 8...

Page 15: ...Fisher Fuch sia R54 Special Laven der R64 Light Steel Blue R364 Blue Bell R65 Daylight Blue R80 Primary Blue R81 Urban Blue R82 Surprise Blue R382 Congo Blue R83 Medium Blue R383 Sapphire Blue R90 Dk...

Page 16: ...amber LED maximum value Lime Sets lime LED maximum value LED Frequency 600Hz Selects the PWM output frequency 1200Hz 2000Hz 2400Hz 6000Hz 18KHz 25KHz Display Normal Normal display orientation Inverte...

Page 17: ...son 1 Select a DMX personality as shown in DMX Personalities 2 Set the running mode a Go to the Master Slave main level b Select the Master programming level 3 Set the starting address a Go to Start A...

Page 18: ...011 255 No function Strobe slow to fast 16 Red 2 000 255 0 100 17 Red Fine 2 000 255 0 100 18 Green 2 000 255 0 100 19 Green Fine 2 000 255 0 100 20 Blue 2 000 255 0 100 21 Blue Fine 2 000 255 0 100 2...

Page 19: ...Setting 1 Dimmer 000 255 0 100 2 Dimmer Fine 000 255 0 100 3 Red 1 000 255 0 100 4 Green 1 000 255 0 100 5 Blue 1 000 255 0 100 6 Amber 1 000 255 0 100 7 Lime 1 000 255 0 100 8 Virtual Color Wheel 1...

Page 20: ...art section for specific values 16 Strobe 2 000 010 011 255 No function Strobe slow to fast 17 Strobe All 000 010 011 255 No function Strobe slow to fast RGB EXT 15 CH Channel Function Value Percent S...

Page 21: ...000 255 0 100 9 Amber 2 000 255 0 100 10 Lime 2 000 255 0 100 RGBA 8CH Channel Function Value Percent Setting 1 Red 1 000 255 0 100 2 Green 1 000 255 0 100 3 Blue 1 000 255 0 100 4 Amber 1 000 255 0 1...

Page 22: ...fic values 14 Color Temperature 1 000 255 Refer to the Preset Color Temperature Chart section for specific values 15 Strobe 000 010 011 255 No function Strobe slow to fast 16 Color Macros 000 015 016...

Page 23: ...Blue 000 255 0 100 6 Amber 000 255 0 100 7 Virtual Color Wheel 000 255 Refer to the Virtual Color Wheel Chart section for specific values 8 Color Temperature 000 255 Refer to the Preset Color Tempera...

Page 24: ...3 Select an auto program as explained in Auto Programs or VCW RGBA 4CH Channel Function Value Percent Setting 1 Red 000 255 0 100 2 Green 000 255 0 100 3 Blue 000 255 0 100 4 Amber 000 255 0 100 RGB 3...

Page 25: ...M Manual Color Mixer 3 Select the desired color Red Green Blue Amber or Lime 4 Select the color value 000 255 5 Repeat for the other colors Color Temperature The color temperature mode allows for perm...

Page 26: ...mation main level 2 Select UID Device Name This option displays the products name 1 Go to the Information main level 2 Select Device ID Factory Reset This option restores the Ovation C 805FC to the or...

Page 27: ...ut Red Value Green Value Blue Value Amber Value Lime Value 000 005 006 013 014 021 022 028 029 035 036 043 044 051 052 059 060 067 068 075 076 083 084 091 092 099 100 107 108 115 116 121 122 130 131 1...

Page 28: ...increased mechanical wear To clean the product 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust coll...

Page 29: ...ucts 13 6 A 17 products Fuse T 3 15 A 250 V T 3 15 A 250 V Power I O U S Worldwide UK Europe Power input connector Neutrik powerCON A Neutrik powerCON A Power output connector Neutrik powerCON B Neutr...

Page 30: ...RMA number Chauvet will refuse any product returned without an RMA number Once you have the RMA number provide the following information on a piece of paper and place it inside the box Your name Your...

Page 31: ...Website Toll Free 800 762 1084 www chauvetlighting com EUROPE General Information Technical Support Address Stokstraat 18 Email eutech chauvetlighting eu 9770 Kruishoutem Website Belgium www chauvetl...

Reviews: