background image

E-882-4-E

1. BEFORE YOU BEGIN

Every OVAL product is thoroughly tested and inspected before shipment from our factory. 

When  received,  its  appearance  should  be  inspected  for  possible  damage  by  rough  handling  during 

transit. First of all, thoroughly read the handling precautions described in this section. For topics other 

than those covered in this section, refer to the respective sections of this manual.

If at any time in the future you seek our assistance, contact the nearest sales office in your area.

1.1 Confirming the Nameplate

The  instrument  is  adjusted  to  individual  specifi-

cations  before  shipment  from  our  factory.  Model 

number appears on the nameplate attached to the 

top of the housing. 

Make sure to see that the instrument you received 

conforms  to  the  General  Specifications  (page  16) 

and the Product Code Explanation (page 8).

When  you  inquire,  supply  complete  informa-

tion  as  to  the  product  name,  model  number, 
product  number,  ratings,  and  other  pertinent 
information.

1.2 Transportation Precautions

(1)  In  order  to  safeguard  against  damage  during  transit,  transport  your  instrument  to  the  installation 

location in the original package used for shipment from the factory if possible.

(2) Use care to avoid impact shocks to the instrument during transit.

1.3 Storage Precautions

If the instrument upon receipt is to be stored for extended periods of time before installation, unexpected 

problems could arise. If such is the case, the following considerations should be taken:

(1) The instrument can best be stored in the original package used for transit from the factory.

(2) The place of storage should meet the following requirements:

  Free from rain and water

  Free from vibration and impact shocks

  With minimal temperature and humidity variation (around 25

°

C and 65% R.H.)

Fig. 1.1 Nameplate Location

Nameplate 

(model number)

EL4001 is the 

generic desig-

nation of the 

EL4001 series 

computers.

Summary of Contents for EL4121

Page 1: ...knowledge contained in this manual you can expect the best possible results over a long service life of this instrument Keep this manual for ready reference It is suggested that the instruction manual...

Page 2: ...6 INTERNAL COMPONENTS AND FUNCTIONS 9 6 1 Front Panel 9 6 1 1 Display 9 6 1 2 On Screen Menu Items 9 6 1 3 Error Messages 10 6 1 4 Front Panel Keypad 10 7 CALCULATION FORMULAS 11 7 1 Implementation o...

Page 3: ...170 9 EL4501 175 10 DIP SWITCH CONFIGURATION 182 Model with communication capabilities COMMUNICATION MANUAL Ins No E 880CM E CONTENTS 1 COMMUNICATION CAPABILITY OVERVIEW 5 2 NETWORK CONFIGURATION 5 3...

Page 4: ...ou inquire supply complete informa tion as to the product name model number product number ratings and other pertinent information 1 2 Transportation Precautions 1 In order to safeguard against damage...

Page 5: ...n also carry out calculations as a pressure compensator with temperature value fixed 2 1 Features 1 Changing the meter factor ranges of temperature pressure or other parameters of the companion flowme...

Page 6: ...at ambient temperatures up to 50 C it is recommended that the instrument be placed in service at room temperature 3 Provide a sufficient working space behind the instru ment at least 50 centimeters f...

Page 7: ...instrument Fig 4 1 4 3 Description of Terminal Blocks for External Connections Terminal blocks for external connections TB1 TB2 and TB3 are found on the back of the instrument as shown in Fig 4 1 Ter...

Page 8: ...4VAC or 20 to 30VDC 2 N 3 Ground Screws on the terminal block M3 5 Pt100 3 wire 5 PRODUCT CODE EXPLANATION Table 5 1 Item Product Code Description Model E L 4 1 2 1 Temperature pressure compensated fl...

Page 9: ...alibrated for meter error and corrected for temperature and pressure is indi cated 5 Temperature TEMPERATURE The temperature value currently fed to the instrument is indicated If a problem arises in t...

Page 10: ...tion can store a maximum of 20 events each of which consists of year month day hour and minutes of error occurrence and recovery Complete details are covered in the Key Operation Manual 6 1 4 Front Pa...

Page 11: ...273 15 K p Line pressure MPa p0 Correction reference pressure MPa t Line temperature t0 Correction reference temperature is a correction factor as a quadratic factor of temperature and pressure Consta...

Page 12: ...yed NOTE See the KEY OPERATION MANUAL 3 Inject a simulated input pulse train or density signal representing the type of the companion pulse generator 4 Select display menu items of the total mass flow...

Page 13: ...messages PRESS 1 OVER or PRESS 1 UNDER Same also with PRESS 2 1 Input signal line correctly wired 2 Input signal specifications matched 3 System configured correctly 4 Pressure range set correctly 1...

Page 14: ...ty converter circuit error 14 TEMP 1 PT OVER Temperature Pt input 1 overflow 15 TENP 1 PT UNDER Temperature Pt input 1 underflow 16 TEMP 2 PT OVER Temperature Pt input 2 overflow 17 TEMP 2 PT UNDER Te...

Page 15: ...Ckt analog Temp Input Ckt analog Temp Input Ckt Pt Analog Output Circuit Pulse Output Circuit 1 Pulse Output Circuit 2 Pulse Output Circuit 3 Multi plexer Isolation Test Pins Test Pins Internal Volt B...

Page 16: ...rature To the 2nd decimal place when C is selected Pressure To the 4th decimal place when MPa is selected Correction factor To the 4th decimal place Meter error corr factor To the 5th decimal place 3...

Page 17: ...E 882 4 E All specifications are subject to change without notice for improvement 2017 01 Revised 2008 08 Released E 882 4 E 1...