11. GENERAL SPECIFICATIONS
11.1 General Specifications
Table 11.1
Item
Description
Nominal Diameter and Connection
10, 15, 25, 40, 50, 80, 100mm, wafer type
Flange Ratings
JIS 10, 16, 20, 30K ASME/JPI 150, 300 (10mm in nominal dia. is excluded.)
Standard Process Connection
Nominal thickness Sch. 40
Acceptable Fluids
Liquid, gas, and steam (Steam is not acceptable for meters 10mm in norminal dia.)
Flow Range
See tables below.
Operating
Temperature
Fluid
Standard type: -10 to +80°C, High temperature type: -10 to +200°C)
Ambient
−10 to +60°C
Max. Operating Pressure
Depending on process connection ratings. (Design pressure: 5MPa) See Note 1.
Accuracy
Better than ±1% of full scale See Note2.
(*: In the analog output, ±0.5% of full scale is added.)
Materia
l
s
Meter body, bluff body
SCS14A (nominal dia. 10mm meter body: SCS14A; bluff body: SUS316)
Sensor
10 to 25: SUS316 40 to 100mm: XM19 (super stainless steel)
Adapter
SCS3A
Preamplifier housing
Polycarbonate
Physical Orientation
No restrictions to cause loss of accuracy.
(Take into consideration the ease of servicing and waterproofing at cable entry.)
Preamplifier Model
PA55
Preamplifier Mounting Construction
Integrally mounts on the meter.
Display
(LCD digital readout)
(1) Accumulated total flow 8 digits
(2) Hourly instant flowrate 5 digits
(3) Per-minute instant flowrate 5 digits
(4) Resettable total flow 7 digits
(1), (2), (3), (4) are selectable externally with selector
magnet furnished.
Flow units [L, m
3
, g, kg, t, L (norm.), m
3
(norm.)] along
with decimal point shown on the LCD (rotatable through 360°).
Output Signals
Battery powered
None
Externally powered*
Analog output 4 to 20mA at 0 to FS (analog trim with front panel switches)
Alarm output
Open collector output
Allowable current: 20mA
Max. voltage impression: 30V
Front panel LED (in red) shows alarm status. [High and low alarm output status
(ON/OFF selectable) and settings are adjustable with front panel switches.]
Pulse output
Open collector output Allowable current: 20mA
Max. voltage impression: 30V
Pulse width (Factored pulse: 30ms Unfactored pulse: 1 ms)
Power
Battery powered
Lithium battery pack
Battery life: 4 years at room temp. ... A low battery alarm is provided.
Externally powered
to 45VDC
Signal Cable
5-conductor shielded cable (one meter long furnished)
Transmission Length
1 kilometer when extended with cable 2.00mm
in conductor area)
Installation Location
(1) Free from rain and water, (2) Minimal temp. change, (3) Free from direct sunlight
Backup
Retains parameters and variables in an internal EEPROM memory.
NOTE*: You cannot use an analog output and open collector at the same time.
NOTE 1: Flange ratings and the maximum operating pressure
Unit in MPa
Flange Rating
JIS 10K
JIS 16K
JIS 20K
JIS 30K
ASME/JPI 150
ASME/JPI 300
Max. Operating Pressure
.8
.96
.45
4.5
.
3.0
NOTE 2: Accuracy of size 10mm meter is ±2%, or better, of full scale.
n
Nominal Meter Factors and Flow Ranges
Fluid
Dia. (mm) Nom. meter factor (L/P) Flow range (m
3
/h)
Fluid
Dia. (mm) Nom. meter factor (L/P) Flow range (m
3
/h)
Liquid
0
0.00485
0. to
.
Liquid
0
0.043
.5 to
8.5
5
0.0335
0.3 to
4.7
5
0.06673
3
to
8
5
0.08065
0.7 to
6
5
0.4033
7.5 to
60
40
0.04556
. to
3
40
0.78
3
to 9
50
0.00
to
53
50
0.5005
0
to 99
80
0.338
4.6 to 8
80
.664
44
to 74
00
0.7567
to 05
00
3.784
76
to 80
NOTES 1. Flow range of liquid service meter shows that of water (at 20°C)
2. Flow range of gas service meter shows that of air (0.5MPa at 20°C)
NOTE: Operating flow range and preamplifier output specifications are stated on the nameplate.
}