D-555-3-E
0
Kind 2 Unit setup parameter (Un)
In the parameter setup mode, the measurement unit to be set up flickers.
MODE ... Not used in the setup process.
RESET ... Each time the switch is turned ON, the measurement unit indicated changes one after another.
→
When the desired measurement unit appears, press the MODE switch twice (the unit is established
and the screen returns to the review mode).
Kind 3 Decimal point setup parameters (bP and SP)
In the parameter setup mode, a figure representing the decimal places of interest flickers.
MODE ... Not used in the setup process.
RESET ... Each time the switch is turned ON, the decimal point moves to the left and the figure increases
by one.
→
When the decimal point appears at the desired place, hold the MODE switch depressed for 2
seconds (the setting is established and the screen returns to the review mode).
Example: Parameter "Un" (indicated measurement unit)
Each time the RESET switch is turned ON, the indicated unit changes one after another through available units as
[g
→
kg
→
t
→
L
→
kL
→
m
3
→
L(normal)
→
kL(normal)
→
m
3
(normal)
→
none].
Indicated measurement unit
(Flickers.)
Example: Parameter "bP" (decimal place in instantaneous flowrate)
Relative to the figure at right of decimal point,
this point moves.
A figure representing the decimal places of interest (flickers)
Pressing RESET button ON, the figure increases by one
("0"
→
"1"
→
"2").
If a setting above (bP=2) is chosen, the instantaneous flowrate reads [b1
���
.
��
].