Refrigerator Instruction
Page 3 of 9
3.
Operation
■
Power
:
The electronic device can control the compressor system and have the
function of battery protection. When the input voltage comes to the minimum, it can
stop the compressor; when the voltage comes back to the normal value, the
compressor will rework automatically.
■
Battery Protection:
Selecting the Low
、
Med
、
High positions of the switch, you can
choose different levels for battery protection. Here below you can find the battery
tension values when the compressor stops running (cut-out) and when the
compressor restarts working (cut-in).
■
Battery electric power display
Battery
section
LCD Display
Battery level
1
9.7V
2
10.4V
3
11.1V
4
11.8V
5
12.5V
6
13.2V
■
Buzzing
1.If you press any button, the refrigerator will have a buzzer alarm sound.
Battery protection
12V
CUT-OUT
12V
CUT-IN
24V
CUT-OUT
24V
CUT-IN
LOW
9.6V
10.9V
21.6V
23.0V
MED
10.1V
11.4V
22.3V
23.7V
HIGH
11.3V
12.6V
24.3V
25.7V