background image

15 

 

♦ 

Power Supply 

The  power  supply  must  conform  to  the  specifications  of  the  appara-
tus. 
 

♦ 

Lanx HD

® 

System Maintenance 

Any System breakdown caused by neglect or during maintenance by 
an  unauthorized  source  is  excluded  from  the  warranty;  any  damage 
caused by neglect will be charged to the user.  

 

♦ 

Cable protection 

 All  wires  and  cables  must  be  installed  without  being  stretched  or 
crushed  whilst  also  avoiding  the  possibility  of  splitting  from  constant 
vibration during the movement of the vehicle.  

 

♦ 

Truck maintenance 

Before performing maintenance on the truck make sure that the Sys-
tem is completely disconnected. 
In particular, when performing maintenance, changing air spring lev-
elling  valves  or  leaf  spring  suspensions,  calibrating  the  Lanx  HD

®

 

system is required.  
Welding,  battery  replacement,  battery  charging  or  external  motors 
could seriously damage the system.   

 

♦ 

Cleaning of the vehicle 

During  cleaning  using  a  jet  wash  or  other,  avoid  spraying  directly 
onto the system components. 

 

♦ 

Non-utilization period 

 

Check that the Lanx HD

®

 System is switched off. 

 

 
 

 
 

 

 
 
 
 
 
The society Outset

®

 Srl reserves the right to update or modify the products or the functionality 

described in this manual at any moment without prior notice. 

6

  Safety Rules  

Summary of Contents for Lanx HD

Page 1: ...on board weighing during loading Productivity control Automatic weighing Protection against early wear of the vehicle Reusable system User Guide User Guide User Guide User Guide Lanx HD only for heavy...

Page 2: ...2...

Page 3: ...ls 09 4 7 Edit operators 09 4 8 Tare 10 4 9 Materials 10 5 Setup Functions PIN CODE unlock 10 5 1 Weighing delay 10 5 2 Sensitivity 11 5 3 Language 11 5 4 Unit of measure 11 5 5 Sec TX system Ext 12 5...

Page 4: ...switching the LANX HD display on or off F BUTTON Button for selecting the main functions operator sel print loads de lete load PIN CODE unlock loads Database diagnostic edit materials edit opera tors...

Page 5: ...to select the operator or the loading desti nations Press the OK button to confirm the operation 4 2 Print loads This function allows the user to print the weights measured during the day The date tim...

Page 6: ...ve data E g a SAVE LOADS DB allows to save the weights made through a USB Flash Drive device Press the Functions button and the and buttons until the following appears on the display Press the OK butt...

Page 7: ...ys c DAILY PRT TOT allows the user to print the totals of all the weight meas urements made in a single day or within an interval of days Press OK to display Use the and buttons to change the number o...

Page 8: ...bration The user is able to control the operat ing pressures of the vehicle after calibration Press the Functions button and the and buttons until the following appears on the display Press the OK but...

Page 9: ...destina tions Press the Functions button and the and buttons until the following appears on the display Press the OK button to select the operator destination Press the and buttons to scroll the chara...

Page 10: ...ssary to enter a protective PIN CODE to unlock the functions See the Calibration manual They can be used to perform the calibration set the load limits for external alarms enter the weighing delay mod...

Page 11: ...ns button several times to exit this function 5 4 Unit of measure This function determines the chosen unit of measure for the display weight which can be either kilograms tonnes or lbs On the printed...

Page 12: ...um correction allowed is 10 Enter the Setup menu as described at the beginning of section 5 and press and until the following appears on the display Press the OK button and use the and buttons to sele...

Page 13: ...the following appears on the display Press OK to enable the fixed alarm Press OK to disable the fixed alarm To set a value press OK and hold down or until the desired value is displayed then press OK...

Page 14: ...isplay Press the OK button to display the 1st sensor Press the OK button and hold down or to set the desired value Press the OK button and to display the 2nd sensor Press the OK button and hold down o...

Page 15: ...e Before performing maintenance on the truck make sure that the Sys tem is completely disconnected In particular when performing maintenance changing air spring lev elling valves or leaf spring suspen...

Page 16: ...ourney time during the warranty period The instruments to repair replace or change must be returned to the vendor head office and in case of technical intervention in the utilization place the relativ...

Page 17: ...he following parts articles of harmonized standards and regulation have been applied EN55022 class A EN 55024 EN 55022 Enclosure radiated emission EN 55022 DC mains conducted emissions EN 61000 4 3 En...

Page 18: ...18...

Page 19: ...19...

Page 20: ...20...

Reviews: