7.2  Mounting

All  Outline   amplifiers  are  designed  for  standard  19”  rack 

mounting with four front panel holes and two rear-lateral holes. In 
order to limit the risk of mechanical damages, amplifiers must be 
fixed to the rack using both frontal as well as rear mounting holes 
(see FIGURE 9).

7.3  Cooling

All Outline  amplifiers implement a forced-air cooling system 

to maintain low and constant operating temperatures. Drawn by 
an internal fan, air enters through the slots in the front panel and 
is forced over all components, exiting at the back of the amplifier.

The amplifier’s cooling system features an “intelligent” variable-

speed DC fan which is controlled by heat sink temperature sensing 
circuits:  the  fan  speed  will  increase  only  when  the  temperature 
recorded by the sensors rises over carefully predetermined values. 
This ensures that fan noise and internal dust accumulation are kept 
to a strict minimum. Should however the amplifier be subject to 
an extreme thermal load, the fan will force a very large volume 
of air through the heat sink. In the extremely rare event that the 
amplifier should dangerously overheat, sensing circuits shut down 
all  channels  until  the  amplifier  cools  down  to  a  safe  operating 
temperature. Normal operation is resumed automatically without 
the need for user intervention.

Caution  regarding  heat  escape  should  be  exercised  when 

mounting  M5000-4   amplifier.  Exhaust  cooling  air  is  forced  out 
through the rear of the chassis (see  FIGURE 5); make sure there 
is  enough  space  around  the  back  of  the  amplifier  for  this  air  to 
escape. M5000-4 amplifiers can be stacked one on top of the other 
due to the efficient cooling system they are equipped with. There 
is however a safety limit to be observed: in case a rack with closed 
back panels is used, leave one rack unit empty every four installed 
amplifiers to guarantee adequate air flow.

7.4   Operating precautions

Make sure the power switch is off before attempting to make 

any input or output connections.

Make sure the AC mains voltage used is within the acceptable 

operating voltage range specified in the M5000-4  documentation 
(factory selected 115 V / 230 V ±15%), depending on your country 

mains standard. Damage caused by connecting the amplifier to an 
improper AC mains voltage is not covered by the warranty.

By using good quality input and speaker cables, the likelihood 

of erratic signal behavior is reduced to a minimum. Whether you 
make them or buy them, look for good quality wires, connectors 
and soldering techniques.

7.5  Grounding

There is no ground switch or terminal on the M5000-4 amplifier. 

All shield terminals of input connections are directly connected to 
the chassis. This means that the unit’s signal grounding system is 
automatic. In order to limit hum and/or interference entering the 
signal path, use balanced input connections.

In the interests of safety, the unit MUST always operate with 

electrical safety earth connected to the chassis via the dedicated 
wire in the 3-wire cable. Never disconnect the ground pin on the  
AC mains power cord.

7.6   AC mains connection

The AC Mains connection is made via the IEC type connector 

on  the  back  of  the  amplifier.  Please  make  sure  your  AC  mains 
power source operates within the voltage limits indicated on this 
manual (factory selected 115 V / 230 V ±15%).

Safety warning! 

Ground wires must be connected! 

Do not use adapters that disable grounding.

operation.  For  optimal  amplifier  performance,  it  is  important  to 

This section provides information on amplifier connection and

under s tand  the  meaning  of  the  infor mation  that  M5000-4  
amplifier can provide regarding its status and configuration. 

8.1  Front panel air filters access

The grey front panel of M5000-4  amplifier can be removed 

to access the air filters. This is useful when the air filters need to 
be cleaned due to dust accumulating and clogging the filters thus 
hindering proper air circulation vital for cooling purposes.

air flow

mounting

holes

brackets

FIGURE 5: M5000-4 air flow.

open the lock and 
insert the plug

lock the plug

FIGURE 6: AC mains plug connection.

8  Connections and Operation 

The Sound of Big Ideas

Outline s.r.l. - Via Leonardo da Vinci, 56 - 25020 Flero (Brescia) - Italy

Tel. +39-30-3581341 Fax +39-30-3580431 — Web Site: www.outline.it  E-Mail: [email protected]

8

Summary of Contents for M5000-4

Page 1: ...The Sound of Big Ideas M5000 4 FOUR CHANNEL AMPLIFIER The Sound of Big Ideas USER GUIDE TEMP READY SIGNAL 18dB 6dB CLIP dB 32 8 dB 32 8 M5000 4...

Page 2: ...regarding installation 3 Mechanical drawings 4 Interfaces 5 Welcome 6 Description 7 Installation M5000 4 User Guide 9 Protection 10 9 1 Turn on Turn off muting 10 9 2 Short circuit protection 10 9 3 T...

Page 3: ...EN 55103 2 standard This equipment has been tested and found to comply by Notified Body 2014 Directive 2006 95 EC pursuant to the audio appa ratus safety requirements EN 60065 and EN 6006 A1 standard...

Page 4: ...are capable of producing much more power than many loudspeakers can han dle It is the user s responsibility to use speakers suitable to the amplifier and to use them in a sensible way that will not c...

Page 5: ...drawing All dimensions in millimiters TEMP READY SIGNAL 18dB 6dB CLIP dB 32 8 dB 32 8 M5000 4 Outline s r l Via Leonardo da Vinci 56 25020 Flero Brescia Italy Tel 39 30 3581341 Fax 39 30 3580431 Web...

Page 6: ...13 Link switch channels 3 4 14 Channel 3 output Speakon connector 15 Channel 2 output Speakon connector 16 Link switch channels 1 2 17 Channel 1 output Speakon connector FIGURE 2 M5000 4 front panel v...

Page 7: ...to work with lo Z from 4 and with 70V 100V distributed lines It can deliver up to 1250 W per channel at 4 or 2500 W in bridge mode on 8 Outline amplifiers deliver crystal clear highs and a tight well...

Page 8: ...the acceptable operating voltage range specified in the M5000 4 documentation factory selected 115 V 230 V 15 depending on your country mains standard Damage caused by connecting the amplifier to an...

Page 9: ...LED will turn off automatically when the temperature falls below 75 C TABLE 1 M5000 4 LEDs chart 8 4 Connecting audio inputs Audio input connections are made via four XLR connectors found on the rear...

Page 10: ...for another 2 seconds and the procedure will reiterate The red CLIP LED will be turned off only when the output current draw will have returned within safe limits 9 3 Thermal protection Outline M5000...

Page 11: ...l interfere with cooling You may use compressed air to remove the dust from filters To remove air filters please refer to the front panel removal procedure see Section 8 1 Air filter cleaning should b...

Page 12: ...0 100 Hz Front panel Indicators 4 LEDs per channel 3 x green 1 x red 4 status LEDs 2 x green 2 x yellow Controls 1 stepped level attenuator pot per channel mains switch Maintenance Dust filter foam be...

Reviews: