background image

1  Important safety instructions

CAUTION:  TO  REDUCE  THE  RISK  OF  ELECTRIC  SHOCK, 
DO NOT ATTEMPT TO OPEN ANY PART OF THE UNIT. NO 
USER-SERVICEABLE  PARTS  INSIDE.  REFER  SERVICING  TO 
QUALIFIED SERVICE PERSONNEL.

WARNING: TO  REDUCE THE  RISK  OF  FIRE  OR  ELECTRIC 
SHOCK,  DO  NOT  EXPOSE THIS APPARATUS TO  RAIN  OR 
MOISTURE. OBJECTS FILLED WITH LIQUIDS, SUCH AS VAS-
ES, SHOULD NOT BE PLACED ON THIS APPARATUS.

TO  COMPLETELY  DISCONNECT  THIS  APPARATUS  FROM 
THE AC MAINS, DISCONNECT THE POWER SUPPLY CORD 
PLUG FROM THE AC RECEPTACLE.

THE  MAINS  PLUG  OF THE  POWER  SUPPLY  CORD  MUST 

 

REMAIN READILY ACCESSIBLE.

SAFEGUARDS: This unit has been engineered and manufactured 
to assure your personal safety. Improper use can result in potential 
electrical  shock  or  fire  hazards.  In  order  not  to  defeat  the safe

-

guards, observe the following instructions for its installation, use 
and servicing.

 

u

Read these instructions.

 

u

Keep these instructions.

 

u

Heed all warnings.

 

u

Follow all instructions.

 

u

Do not use this amplifier near water.

 

u

Clean only with a dry cloth.

 

u

Ensure a proper ventilation. 

 

u

Install in accordance with Outline instructions.

 

u

Do  not  install  near  any  heat  sources  or  apparatus  that 
produce heat.

 

u

Protect  the  power  cord  from  being  walked  on  or  pinched 
particularly at plugs, convenience receptacles, and the point 
where they exit from the apparatus.

 

u

Do  not  defeat  the  safety  purpose  of  the  polarized  or 

grounding-type  plug.  A  polarized  plug  has  two  blades  with 
one  wider  than  the  other. A  grounding  type  plug  has  two 
blades  and  a  third  grounding  prong. The  wide  blade  or  the 
third  prong  are  provided  for  your  safety.  If  the  provided 
plug  does  not  fit  into  your  outlet,  consult  an  electrician  for 
replacement of the obsolete outlet.

 

u

Unplug this amplifier during lightning storms or when unused 

for long periods of time.

 

u

Contact  the  authorized  service  center  for  ordinary  and 

extraordinary maintenance. 

 

u

Only use attachments/accessories specified by Outline .

NOTES: This  equipment  has  been  tested  and  found  to  comply 
by  Competent  Body  (Directive  2004/ 108  /  EC)  pursuant  to  the 
product  family  standard  for  audio  professional  use:  EN  55103-1 
and EN 55103-2 standard.
This equipment has been tested and found to comply by Notified 
Body 2014 (Directive 2006/  95 / EC) pursuant to the audio appa-
ratus safety requirements: EN 60065 and EN 6006/A1 standard.

EXPLANATIONS OF GRAPHICAL SYMBOLS

The  Lightning  Flash  with  arrowhead  symbol  within  an 
equilateral  triangle  is  intended  to  alert  the  user  to  the 
presence  of  uninsulated  “dangerous  voltage”  within  the 
product enclosure that may be of sufficient magnitude to 
constitute a risk of shock to persons.

The  Exclamation  Point  within  an  equilateral  triangle  is 
intended  to  alert  the  user  to  the  presence  of  important 
operating and maintenance (servicing) instructions in the 
literature accompanying the product.

2.1  Location

Install the amplifier in a well-ventilated location where it 
will not be exposed to high temperature or humidity.

Do not install the amplifier in a location that is exposed to direct 
sun rays, or near hot appliances or radiators. Excessive heat can 
adversely affect the cabinet and internal components. Installation 
of  the  amplifier  in  a  damp  or  dusty  environment  may  result  in 
malfunction or accident.

Placing and using the amplifier for long periods of time on 
heat generating sources will affect its performance. Avoid 

placing  the  amplifier  on  heat  generating  sources.  Install  this  am-
plifier  as  far  as  possible  from  tuners  and  TV  sets.  An  amplifier 
installed  in  close  proximity  of  such  equipment  may  experience 
noise or generic performance degradation.

No naked flame sources such as lighted candles should be 
placed on the amplifier.

Do not spill water or other liquids into or on the amplifier.

WARNING
To prevent fire or electric shock:

 

u

The ventilation openings must not be impeded by any item 
such as newspapers, tablecloths, curtains etc; keep a distance 
of at least 50 cm from the front and rear ventilation openings 
of the amplifier.

 

u

Do not expose this amplifier to rain or moisture.

 

u

This equipment must not be exposed to dripping or splashing 
liquids: objects filled with liquids, such as vases, must not be 
placed on the amplifier.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

!

2  Precautions regarding installation

Outline s.r.l. - Via Leonardo da Vinci, 56 - 25020 Flero (Brescia) - Italy

Tel. +39-30-3581341 Fax +39-30-3580431 — Web Site: www.outline.it  E-Mail: [email protected]

3

Professional Amplifier

M5000-4

Summary of Contents for M5000-4

Page 1: ...The Sound of Big Ideas M5000 4 FOUR CHANNEL AMPLIFIER The Sound of Big Ideas USER GUIDE TEMP READY SIGNAL 18dB 6dB CLIP dB 32 8 dB 32 8 M5000 4...

Page 2: ...regarding installation 3 Mechanical drawings 4 Interfaces 5 Welcome 6 Description 7 Installation M5000 4 User Guide 9 Protection 10 9 1 Turn on Turn off muting 10 9 2 Short circuit protection 10 9 3 T...

Page 3: ...EN 55103 2 standard This equipment has been tested and found to comply by Notified Body 2014 Directive 2006 95 EC pursuant to the audio appa ratus safety requirements EN 60065 and EN 6006 A1 standard...

Page 4: ...are capable of producing much more power than many loudspeakers can han dle It is the user s responsibility to use speakers suitable to the amplifier and to use them in a sensible way that will not c...

Page 5: ...drawing All dimensions in millimiters TEMP READY SIGNAL 18dB 6dB CLIP dB 32 8 dB 32 8 M5000 4 Outline s r l Via Leonardo da Vinci 56 25020 Flero Brescia Italy Tel 39 30 3581341 Fax 39 30 3580431 Web...

Page 6: ...13 Link switch channels 3 4 14 Channel 3 output Speakon connector 15 Channel 2 output Speakon connector 16 Link switch channels 1 2 17 Channel 1 output Speakon connector FIGURE 2 M5000 4 front panel v...

Page 7: ...to work with lo Z from 4 and with 70V 100V distributed lines It can deliver up to 1250 W per channel at 4 or 2500 W in bridge mode on 8 Outline amplifiers deliver crystal clear highs and a tight well...

Page 8: ...the acceptable operating voltage range specified in the M5000 4 documentation factory selected 115 V 230 V 15 depending on your country mains standard Damage caused by connecting the amplifier to an...

Page 9: ...LED will turn off automatically when the temperature falls below 75 C TABLE 1 M5000 4 LEDs chart 8 4 Connecting audio inputs Audio input connections are made via four XLR connectors found on the rear...

Page 10: ...for another 2 seconds and the procedure will reiterate The red CLIP LED will be turned off only when the output current draw will have returned within safe limits 9 3 Thermal protection Outline M5000...

Page 11: ...l interfere with cooling You may use compressed air to remove the dust from filters To remove air filters please refer to the front panel removal procedure see Section 8 1 Air filter cleaning should b...

Page 12: ...0 100 Hz Front panel Indicators 4 LEDs per channel 3 x green 1 x red 4 status LEDs 2 x green 2 x yellow Controls 1 stepped level attenuator pot per channel mains switch Maintenance Dust filter foam be...