Outland Technology FMPPC2-2 Owner'S Manual Download Page 5

En-4

  1-888-514-1663  |  

WWW.OUTLANDLIVING.COM

LEAK TEST:

1.  

DO NOT USE OR PERMIT SOURCES OF IGNITION  
IN THE AREA WHILE DOING THE LEAK TEST. 
THIS INCLUDES SMOKING.

2.  

Leak testing should be done once per year or whenever the 
LP gas cylinder or any other gas system part is taken apart, 
serviced or replaced, whichever is more frequent.

3.   Ensure all gas system coupling joints are tight  

and properly attached.

4.   Prepare a leak testing solution of half liquid detergent  

and half water.

5.   Apply the solution to the LP gas delivery system at points as 

shown in illustration indicated on page 3.

6.  

If parts of the fitting begin to produce bubbles, spray liquid, or 
if you smell liquid propane gas, immediately close the valve on 
the tank.

7.   Wait 5 minutes for any gas to dissipate.
8.   After waiting for 5 minutes, the leak(s) must be stopped by 

tightening the loose joints, if possible, or by replacing the 
faulty parts(s) with the part(s) recommended by the appliance 
manufacturer.

THE APPLIANCE IS NOT TO BE USED UNTIL  

ANY LEAK IS CORRECTED.

A gas appliance repairman or LP gas dealer should be called if 
attempts to stop the leak(s) are unsuccessful and, in such case, the 
LP gas supply must be shut off at the cylinder valve or the cylinder 
must be removed from the appliance until the leak(s) is corrected.

Inspect hose prior to each use of the unit. The hose assembly 
must be replaced prior to the appliance being put into operation 
if there is evidence of excessive abrasion or wear, or if the hose 
is damaged. Contact FMI Brands Inc. should you require a 
replacement hose.

Inspect burner prior to each use. Burner must be replaced prior 
to the appliance being put into operation if there is evidence of 
damage. Replacement burners are available from FMI Brands Inc.

Should any part of this appliance (including the burner) become 
soiled or dirty, wipe lightly with a damp cloth. Do not use 
flammable or corrosive cleaning products on or near this unit.

Ensure that gas hose is placed in an area where it is unlikely to 
be tripped over (such as pathways or trails) or subject to other 
accidental damage.

Keep the appliance area clear and free from combustible 
materials, gasoline and other flammable vapors and liquids.

Solid fuels shall not be burned in this appliance. 

Installation must conform with local codes or, in the absence of 
local codes, with either the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1 
or Propane Storage and Handling Code, B149.2, or the Standard for 
Recreational Vehicles, ANSI A 119.2/NFPA 1192, and CSA Z240 RV 
Series, Recreational Vehicle Code, 
as applicable.

NOTE TO INSTALLER: 

Leave this guide with the consumer.

NOTE TO CONSUMER: 

Please retain this guide for future use.

 WARNING:

If the information in this manual is not followed exactly, 
a fire or explosion may result causing property damage, 
personal injury or loss of life.
Installation and service must be performed by a qualified 
installer, service agency or the gas supplier.

Summary of Contents for FMPPC2-2

Page 1: ...D 823 000 V3 Owner s Manual FMI BRANDS INC 107 19052 26 Avenue Surrey B C Canada V3Z 3V7 Toll Free 1 888 514 1663 Fax 1 888 797 9931 Model number FMPPC2 2 Series number 823...

Page 2: ...f Do not touch or handle the firebowl when hot To avoid injury always allow the firebowl to cool down for at least 30 minutes before moving and handling the appliance WARNING For outdoor use only DANG...

Page 3: ...abilizer such as the stabilizer ring included must be used when the appliance is in use Replacement parts and a list of such parts are available from FMI Brands Inc through the contact information pro...

Page 4: ...ave total free area of not less than 1 2 in2 per lb 7 1 cm2 per kg of stored fuel capacity If ventilation openings at floor level area are in the side wall there shall be at least two openings The bot...

Page 5: ...being put into operation if there is evidence of excessive abrasion or wear or if the hose is damaged Contact FMI Brands Inc should you require a replacement hose Inspect burner prior to each use Bur...

Page 6: ...ich have not been allowed to cool from exposure to flame Never attempt to rearrange rocks while unit is ignited Note Rocks are not to exceed a maximum weight of 2 kgs or 4 4 lbs SECTION 2 IGNITION STE...

Page 7: ...parts of your body clothing or any other combustible material are above the burner before during and after ignition SECTION 3 PERIODIC INSPECTION OF BURNER FLAMES STEP 8 GOT A LOW FLAME If your firebo...

Page 8: ...9kg propane cylinder is between 7 and 11 hours depending on where the flame height is set FMI Brands Inc recommends that you ignite this unit only when safely placed on a non combustible surface as pi...