Outland Technology FMPPC2-2 Owner'S Manual Download Page 4

Owner & Safety Manual

D.823.000.V3

En-3

OUTLAND FIREBOWL

®

 OWNER & SAFETY MANUAL 

2

All LP cylinders to be used with this appliance must be: 
a.   Constructed and marked in accordance with the 

specifications for LP-gas cylinders Standard,  
CAN/CSA B339, Cylinders, Spheres and Tubes for the 
Transportation of Dangerous Goods.
 

b.  Provided with a listed overfilling prevention device.
c.  

Provided with a cylinder connection device compatible with 
the connection for outdoor cooking appliances. 

d.   Only a 20 lb. (9 kg) LP gas cylinder is to be used for this 

appliance, approximately 18” (46 cm) high & 12” (30 cm) 
diameter.

e.   The use of an approved LP gas cylinder stabilizer, such as the 

one included, must be used when using this appliance in order 
to prevent the LP gas cylinder from tipping over.

ENCLOSURES FOR SELF-CONTAINED  

LP GAS SYSTEMS:

An enclosure for an LP-gas cylinder shall be ventilated by 
openings at both the upper and lower levels of the enclosure. This 
shall be accompanied by one of the following:
a.   One side of the enclosure shall be completely open; or
b.   For an enclosure having four sides, a top, and a bottom:

At least two ventilation openings (see Part IV, Definitions) shall 
be provided in the sidewalls of the enclosure, located within 5 
in (217 mm) of the top of the enclosure, equally sized, spaced 
at a minimum of 90 degrees (1.57 rad), and unobstructed. The 
opening(s) shall have a total free area of not less than 1 in

2

 per lb 

(14.2 cm

2

 per kg) of stored fuel capacity.

Ventilation opening(s) shall be provided at floor level of the 
enclosure and shall have total free area of not less than 1/2 in

2

 per 

lb (7.1 cm

2

 per kg) of stored fuel capacity. If ventilation openings 

at floor level area are in the side wall, there shall be at least two 
openings. The bottom of the openings shall be 1 in (25.4 mm) or 
less from the floor level and the upper edge no more than 5 in (127 
mm) above the floor level. The openings shall be equally sized, 
spaced at a minimum of 90 degrees (1.57 rad), and unobstructed.

Every opening shall have minimum dimensions so as 
to permit the entrance of a 1/8 in (3.2 mm) diameter rod.
Ventilation openings in sidewalls shall not communicate directly 
with other enclosures of the appliance.

 

CONNECTION:

1.  

Be sure the cylinder valve and appliance valves  
are “off”.

2.  Place full LP gas cylinder on tank stabilizer ring.
3.   Center the nipple in the cylinder valve and hold in place. 
4.   Using the other hand, turn the hand wheel clockwise until 

there is a positive stop. Do not use tools. 

5.   Hand tighten only. When making the connection,  

hold the regulator in a straight line with the cylinder valve, so 
as not to cross thread the connection.

6.   Leak test the connection. See section named “LEAK TEST”.

 

 WARNING:

Ensure that the LP gas cylinder is kept at a minimum 
distance of three feet (36 inches) away from the appliance.

LP Cylinder

Appliance

Tank Ring

Minimum 36”

(0.91m)

LEAK TEST: Apply the solution to the LP gas delivery system at points.  

Valve coupling regulator & Cylinder Coupling. 

LEAK TEST: Apply the solution to the LP gas 

delivery system at points: 

1. Firebowl Valve Coupling 

2. Gas Hose Regulator 

3. Cylinder Valve Coupling

2. Gas Hose 

Regulator

Heat Sensitive

Hand Wheel

Cylinder

Shut Off

Valve

Check Valve

Nipple with

Flow Limiting Device

3. Cylinder Valve 

Coupling

!

Caution:

Trip Hazard!

Tank Ring

Summary of Contents for FMPPC2-2

Page 1: ...D 823 000 V3 Owner s Manual FMI BRANDS INC 107 19052 26 Avenue Surrey B C Canada V3Z 3V7 Toll Free 1 888 514 1663 Fax 1 888 797 9931 Model number FMPPC2 2 Series number 823...

Page 2: ...f Do not touch or handle the firebowl when hot To avoid injury always allow the firebowl to cool down for at least 30 minutes before moving and handling the appliance WARNING For outdoor use only DANG...

Page 3: ...abilizer such as the stabilizer ring included must be used when the appliance is in use Replacement parts and a list of such parts are available from FMI Brands Inc through the contact information pro...

Page 4: ...ave total free area of not less than 1 2 in2 per lb 7 1 cm2 per kg of stored fuel capacity If ventilation openings at floor level area are in the side wall there shall be at least two openings The bot...

Page 5: ...being put into operation if there is evidence of excessive abrasion or wear or if the hose is damaged Contact FMI Brands Inc should you require a replacement hose Inspect burner prior to each use Bur...

Page 6: ...ich have not been allowed to cool from exposure to flame Never attempt to rearrange rocks while unit is ignited Note Rocks are not to exceed a maximum weight of 2 kgs or 4 4 lbs SECTION 2 IGNITION STE...

Page 7: ...parts of your body clothing or any other combustible material are above the burner before during and after ignition SECTION 3 PERIODIC INSPECTION OF BURNER FLAMES STEP 8 GOT A LOW FLAME If your firebo...

Page 8: ...9kg propane cylinder is between 7 and 11 hours depending on where the flame height is set FMI Brands Inc recommends that you ignite this unit only when safely placed on a non combustible surface as pi...

Reviews: