Natural Gas Conversion Kit
En-10
NATURAL GAS CONVERSION KIT - OUTLAND LIVING™ FIRE TABLE - FMPPC2E-410
STEP 12
Test the Igniter to verify the correct
installation and ensure proper spark.
Locate the igniter and the thermocouple
inside the burner tray inside your Fire
Table (under protective shield). Ensure
igniter cover is not covered by glass
rocks. This helps air circulate.
Turn the gas knob until it clicks. A
small spark ignition should be visible
at the tip of the igniter. If the spark is
not working clean dust from igniter tip
and thermocouple post. Try again. If
still not working you have not installed
the igniter cable correctly. Reattach the
igniter cable. Retest. Repeat process
until you verify the spark works.
STEP 13
Install the supplied Quick-Disconnect
(part 5). The quick-disconnect should be
installed by a professional certified natural
gas fitter. Once the quick-disconnect is
properly installed, proceed to the next step.
Low Pressure Natural
Low Pressure Natural
Gas Hose with
Gas Hose with
3/8” male Quick
3/8” male Quick
Disconnect Inlet
Disconnect Inlet
Fitting and 5/8”-18UNF
Fitting and 5/8”-18UNF
Outlet Connector;
Outlet Connector;
MAX. WP 1/2 PSI; 3/8”
MAX. WP 1/2 PSI; 3/8”
diameter, 3.657 m /
diameter, 3.657 m /
12ft length (marked
12ft length (marked
with Yellow Cap)
with Yellow Cap)
3/8” female Quick
3/8” female Quick
Disconnect with
Disconnect with
3/8”-18 NPT Inlet
3/8”-18 NPT Inlet
Connector; MAX. WP
Connector; MAX. WP
1/2 PSI (marked with
1/2 PSI (marked with
Yellow Cap)
Yellow Cap)
STEP 14
Confirm that
the control
knob on the
fire table is
in the OFF
position.
STEP 15
Confirm that
the valve on
your natural
gas box gas
supply is
closed OFF.
OFF
OFF
ENSURE IGNITER AND THERMOCOUPLE (UNDER
IGNITER COVER) IS FREE FROM DUST AND NOT
BLOCKED BY GLASS ROCKS
OFF