background image

En-4

  1-888-514-1663  |  

WWW.OUTLANDLIVING.COM

LEAK TEST:

1.  

DO NOT USE OR PERMIT SOURCES OF IGNITION  
IN THE AREA WHILE DOING THE LEAK TEST. 
THIS INCLUDES SMOKING.

2.  

Leak testing should be done once per year or whenever the 
LP gas cylinder or any other gas system part is taken apart, 
serviced or replaced, whichever is more frequent.

3.   Ensure all gas system coupling joints are tight  

and properly attached.

4.   Prepare a leak testing solution of half liquid detergent  

and half water.

5.   Apply the solution to the LP gas delivery system at points as 

shown in illustration indicated on page 3.

6.  

If parts of the fitting begin to produce bubbles, spray liquid, or 
if you smell liquid propane gas, immediately close the valve on 
the tank.

7.  

Wait 5 minutes for any gas to dissipate.

8.  

After waiting for 5 minutes, the leak(s) must be stopped by 
tightening the loose joints, if possible, or by replacing the 
faulty parts(s) with the part(s) recommended by the appliance 
manufacturer.

THE APPLIANCE IS NOT TO BE USED UNTIL  

ANY LEAK IS CORRECTED.

A gas appliance repairman or LP gas dealer should be called if 
attempts to stop the leak(s) are unsuccessful and, in such case, the 
LP gas supply must be shut off at the cylinder valve or the cylinder 
must be removed from the appliance until the leak(s) is corrected.

Inspect hose prior to each use of the unit. The hose assembly 
must be replaced prior to the appliance being put into operation 
if there is evidence of excessive abrasion or wear, or if the hose is 
damaged.

Contact FMI Brands Inc. should you require a replacement hose.

Inspect burner prior to each use. Burner must be replaced prior 
to the appliance being put into operation if there is evidence of 
damage. Replacement burners are available from FMI Brands Inc.

Inspect the burner tube venturi and ensure the mesh screen is in 
place, prior to each use. Insects will build nests in the tube if they 
can get in and this can cause a back-flame event! Always clear all 
valve and gas orifices of any foreign debris including spider webs 
prior to lighting.  If any doubt there may be a nest inside, use a 
pipe cleaner up the tube.

3

Should any part of this appliance (including the burner) become 
soiled or dirty, wipe lightly with a damp cloth. Do not use 
flammable or corrosive cleaning products on or near this unit.

Ensure that gas hose is placed in an area where it is unlikely to 
be tripped over (such as pathways or trails) or subject to other 
accidental damage.

Keep the appliance area clear and free from combustible 
materials, gasoline and other flammable vapors and liquids.

Solid fuels shall not be burned in this appliance. 

Installation must conform with local codes or, in the absence of 
local codes, with either the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1 
or Propane Storage and Handling Code, B149.2, or the Standard for 
Recreational Vehicles, ANSI A 119.2/NFPA 1192, and CSA Z240 RV 
Series, Recreational Vehicle Code, 
as applicable.

Summary of Contents for FMPPC2F

Page 1: ...UTLAND Flame mark is a registered trademark of FMI Brands Inc Owner s Manual MANUFACTURED BY FMI BRANDS INC 107 19052 26 Avenue Surrey B C Canada V3Z 3V7 USA Canada Toll Free 1 888 514 1663 Tel 1 778...

Page 2: ...d result in fire or explosion which could cause property damage personal injury or death WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other...

Page 3: ...t all adults and children which use or are near a unit in use are aware of the hazard of high surface temperatures present on the unit during use and should use caution and stay away to avoid burns or...

Page 4: ...han 127 mm 5 in above the floor level The openings shall be equally sized spaced at a minimum of 90 degrees 1 57 rad and unobstructed Every opening shall have minimum dimensions so as to permit the en...

Page 5: ...ance being put into operation if there is evidence of excessive abrasion or wear or if the hose is damaged Contact FMI Brands Inc should you require a replacement hose Inspect burner prior to each use...

Page 6: ...one carry strap STEP 1 Remove plastic bags containing the rocks propane stabilizer ring and cover and carry kit STEP 2 Open the single bag containing mid sized rocks labelled conveniently for you M an...

Page 7: ...T empty Close gas supply valve Open and then close the appliance gas knob valve to release pressure Be sure appliance valve is OFF Disconnect and reconnect the cylinder regulator connection Slowly ope...

Page 8: ...trol setting to low for 5 10 minutes or replace the cylinder with a full one 3 Ensure that you clean the bowl of your Outland Firebowl after every use to keep it looking GREAT Simply wipe the outer ed...

Page 9: ...use are aware of the hazard of high surface temperatures present on the unit during use and should use caution and stay away to avoid burns or clothing ignition Do not place any objects other than sup...

Page 10: ...original retail packaging Please register your OUTLAND Living product for proof of purchase and warranty at http outlandliving com register products Registration in English only For more warranty info...

Page 11: ...ASE VISIT WWW OUTLANDLIVING COM The owner s manual is available as a free download from www outlandliving com Should you have any questions or comments regarding this appliance please do not hesitate...

Page 12: ...D 863 000 V4 En 11 Owner Safety Manual OUTLAND FIREBOWL CYPRESS OWNER SAFETY MANUAL...

Reviews: