Propane Gas Cylinder Label

      DANGER • FLAMMABLE GAS UNDER PRESSURE.

 LEAKING LP-GAS MAY CAUSE A FIRE OR EXPLOSION IF IGNITED

CAUSING SERIOUS BODILY INJURY OR DEATH. 

CONTACT LP GAS SUPPLIER FOR REPAIRS, OR DISPOSAL OF THIS

CYLINDER OR UNUSED LP-GAS.

WARNING • FOR OUTDOOR USE ONLY.* 

DO NOT USE OR STORE CYLINDER IN A BUILDING,

GARAGE OR ENCLOSED AREA.

•  Know the odor of LP-gas.  If you hear, see or 

smell leaking LP-gas, immediately get everyone 

away from the cylinder and call the Fire Depart-

ment.  Do not attempt repairs.

•  Caution your LP-gas supplier to:
  Be certain cylinder is purged of trapped air  

  prior to first filling.
  Be certain not to over fill the cylinder.

  Be certain cylinder re-qualification date is  

  checked.

•  LP-gas is heavier than air and may settle in low 

places while dissipating.

•  Contact with the liquid contents of cylinder will 

cause freeze burns to the skin.

•  Do not allow children to tamper or play with cyl-

inder.

• 

When not connected for use, keep cylinder valve 

turned off.  Self contained appliances shall be 

limited to a  cylinder of 30 lb. capacity or less.

•  Do not use, store or transport cylinder where it 

would be exposed to high temperatures.  Relief 

valve may open allowing a large amount of flam

-

mable gas to escape.

• 

When  transporting,  keep  cylinder  secured  in  an 

upright position with cylinder valve turned off,

WARNING:

•  Use only in compliance with applicable codes.
•  Read and follow manufacturer’s instructions.
•  Consult manufacturer’s instructions concerning 

the cylinder connection provided with your appli-

ance.

•  Be sure regulator vent is not pointing up.
•  Turn off all valves on the appliance.
• 

Do not check for gas leaks with a match or open 

flame.   Apply  soapy  water  at  areas  marked  “x”.  

Open cylinder valve.  If bubble appears, close 

valve  and  have  LP-gas  service  person  make 

needed repairs.  Also, check appliance valves and 

connections to make sure they do not leak before 

lighting appliance.

•  Light appliance(s) following manufacturer’s in-

structions.

• 

When  appliance  is  not  in  use,  keep  the  cylinder 

valve closed.

WHEN CONNECTING FOR USE:

Cylinder valve hand wheel

Point of connection

Liquid level indication 

(optional)

Pressure relief valve

Cylinder 

DO NOT REMOVE, DEFACE, OR OBLITERATE THIS LABEL

*EXCEPT AS AUTHORIZED BY 

ANSI/NFPA 58.

DANGER.

  Do not store a spare LP cylinder under or near a barbeque grill, or other heat sources.  

NEVER fill an LP cylinder beyond 80% full: a fire causing death or serious injury may occur.

Summary of Contents for ODPLAZA-L24E

Page 1: ...s and other flammable materials away INSTALLER Leave this manual with party responsible for use and operation OWNER Retain this manual for future reference ODPLAZA L24S ODPLAZA L24E NOTICE DO NOT discard this manual DANGER FIRE OR EXPLOSION HAZARD If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flame 3 If odor continues keep away from the appliance and immediately call your ...

Page 2: ...se store or transport cylinder where it would be exposed to high temperatures Relief valve may open allowing a large amount of flam mable gas to escape When transporting keep cylinder secured in an upright position with cylinder valve turned off WARNING Use only in compliance with applicable codes Read and follow manufacturer s instructions Consult manufacturer s instructions concerning the cylind...

Page 3: ...Product Specific Important Safety Information A Appliance Certification 5 B BTU Specifications 5 C Non Combustible Materials 5 D Combustible Materials 5 E California 5 2 Getting Started A Design and Installation Considerations 6 B Inspect Appliance and Components 6 3 Framing and Clearances A Appliance Dimension Diagram 7 B Clearances to Combustibles 8 C Constructing the Appliance Enclosure 8 D Pro...

Page 4: ...ging and protective materials removed Media installed correctly Reference Media Kit Instructions Manual bag and all of its contents are removed from the firepit and given to the party responsible for use and operation Started appliance and verified no gas leaks exist WARNING Risk of Fire or Explosion Failure to install fire pit acording to these instructions can lead to a fire or explosion Applian...

Page 5: ...on must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or International Fuel Gas Code Natural Gas Propane Gas Burner Pans Orifice 089 43 Orifice 063 52 1 32 000 32 000 2 65 000 65 000 3 100 000 100 000 4 124 000 124 000 5 147 000 147 000 E California WARNING This product and the fuel used to operate this product and the prod ucts of co...

Page 6: ... Risk of Fire or Explosion Damaged parts could impair safe operation DO NOT install damaged in complete or substitute components Keep appliance dry Hearth Home Technologies disclaims any responsibil ity for and the warranty will be voided by the following actions Installation and use of any damaged appliance Modification of the appliance Installation other than as instructed by Hearth Home Technol...

Page 7: ...Use for reference only Figure 3 1 Appliance Dimensions 5 3 8 in 137 mm 2 in 51 mm 45 TYP 7 3 8 in 187 mm A B 5 3 8 in 137 mm Air Shutter Starter Kit Starter 1 extension Starter 2 extensions Starter 3 extensions Starter 4 extensions A 26 in 660 mm 50 in 1270 mm 74 in 1880 mm 98 in 2489 mm 122 in 3099 mm B 24 in 610 mm 48 in 1219 mm 72 in 1829 mm 96 in 2438 mm 120 in 3048 mm ...

Page 8: ... individual design preference Figure 3 2 Clearance to Combustibles Minimum Enclosure Dimensions and Clearances to Combustible Surface A C B D D E Minimum clearances to combustible walls floor and ceiling Appliance enclosure must be made entirely of non combustible materials A B C D E ODPLAZA L24S in 17 17 45 8 8 mm 432 432 1143 203 203 C Constructing the Appliance Enclosure Note Take drainage into...

Page 9: ... the tank Example 05 in2 x 20 lb tank 10 in2 Every opening must have minimum dimensions to allow entrance of a 1 8 in 3 18 mm diameter rod Ventilation openings in side walls must not communicate directly with other enclosures of the linear appliance The cylinder valve must be easily accessible by hand Connections should be easy to leak test inside the enclosure A door on the enclosure is acceptabl...

Page 10: ... the locality In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter A listed and Commonwealth of Massachusetts approved 1 2 inch 13 mm T handle manual shut off valve and flex ible gas connector are connected to the 1 2 inch 13 mm control valve inlet If substituting for these components please consult local codes for compliance C Gas Connection Use ...

Page 11: ...tighten with wrench DO NOT apply sealant to flare fitting side of adapter Note If using additional burner pan extension kits see Section 5C 7 Install pan into enclosure and secure with high temperature adhesive NOTE Burner assembly can be installed on top of the finish materials or under the finishing materials See Figures 5 3 and 5 4 NOTE Be advised that if finishing materials are installed on to...

Page 12: ...flex line to the 1 2 in NPT 3 8 in flare adapter 4 When installing multiple burner extensions a separate valve VK ODPLAZA must be installed for everything over 65 000 BTU of burner for example a 10 ft burner would require 3 three separate valves an 8 ft 2 two valves and a 4 ft 1 one valve Figure 5 8 Extension Kit Brackets 1 2 3 4 5 6 Figure 5 7 Extension Kit ODPLAZA L24E C Burner Extension Install...

Page 13: ... Glass Kit Order Chart Number of Sections WSPLAZA L28S WSPLAZA E24 WSPLAZA E28 Total Dimension 1 1 0 0 28 1 2 x 10 1 4 in 724 x 260 mm 2 1 0 1 56 1 2 x 10 1 4 in 1435 x 260 mm 3 1 1 1 80 1 4 x 10 1 4 in 2038 x 260 mm 4 1 2 1 104 1 2 x 10 1 4 in 2654 x 260 mm 5 1 3 1 128 3 4 x 10 1 4 in 3270 x 260 mm CVR ODPLAZA 24 inch Burner Cover VK ODPLAZA Valve Kit FK ODPLAZA L24S Framing Kit Starter FK ODPLAZ...

Page 14: ...om DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instructions included Leave this manual with party responsible for use and operation Read understand and follow these instructions for safe installation and operation Printed in U S A Copyright 2019 This product may be covered by one or more of the following patents United States 5613487 6006743 6019099 6053165 6145502 63748...