background image

Specifications

WS/HHT/CASTLEWOOD_0717

PRODUCT LISTING CODES

US

UL127

CAN

ULC-S610-M87

Additional information can be found online at www.fireplaces.com

Product information provided is not 
complete and is subject to change 
without notice. Product installation 
must adhere strictly to instructions 
accompanying product to avoid risk of 
fire and potential injury.

A brand of Hearth & Home Technologies

 Inc.

Lakeville, MN                 Web: fireplaces.com        

Phone: 888-427-3973        952-985-6000

FRAMING DIMENSIONS

APPLIANCE LOCATION

CLEARANCES TO COMBUSTIBLES

o

MANTEL AND MANTEL LEG/WALL PROJECTIONS

HEARTH EXTENSION CONSTRUCTION

HEARTH DIMENSIONS

 

Note: If this surface is inside the

building’s war air envelope... 

...then this surface must be an exterior 

wall system. 

29"

[737]

28-1/2"

[724]

1-1/2"

[38]

1-1/2"

[38]

1-1/2"

[38]

1-1/2"

[38]

53" [1344]

54" [1369]

53" [1344]

54" [1369]

95-1/2" [2424]

1/2"

[13]

1/2"

[13]

1/2"

[13]

1/2"

[13]

67-1/2"

[1714]

Castlewood

 

7 ft [2134])

minimum

base of fireplace

to ceiling

Combustible Wall

2 x 4 stud wall

Standoffs

Measured from top 

of fireplace opening

12" [305]

1-1/2" [38]

maximum

22" [559]

minimum

Combustible 

Decorative Facing

Seal joint with

non-combustible

sealant

6"[152]

minimum

12" [305]

minimum

Grid represents

1" squares

Non-combustible

Decorative Facing

such as:

Steel, iron, brick,

tile, concrete, slate,

glass, plasters.

Mantel

* 2" [51]

Continuous, 

non-combustible sealant

Tile, stone or other

non-combustible material

Floor constructed of wood or  

other combustible material 

1" Micore or 

equivalent  insulation 

(see Install Manual)

Fireplace  Protective

Metal Hearth

Strip

Durock

*

*

30-1/2"

[775]

24-1/4"

[616]

41-7/8"

[1064]

2" [51] minimum

air space clearance

to enclosure 

Use only noncombustible

material below the top of

the top standoffs.

28-3/8"

[721]

74-1/2"

[1892]

53-7/8"

[1368]

0" to level of standoffs

0"

1-1/2" [38] to side and back 

unit angled (isometric)

1/2" [13] to framing 

 

18-1/2"

[470]

19 3/4"

[500]

4"

[102]

50° angle

39° angle

24"

[610]

BRICK

FRONT

FLUSH

FRONT

24"

[610]

22-3/8"

[568]

52-7/8"

[1343]

42"

[1067]

Note: Grid depicts 1" squares.

HEARTH EXTENSION

66"

[1676]

42"

[1067]

12"

[305]

12"

[305]

Raised Platform

  20" [508] Minimum

Flush Hearth

  30" [762] Minimum

Reviews: