17
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina-B Owner’s Manual • 4066-501 Rev. G • 7/15
IntelliFire
TM
Plus Ignition System - (continued)
Symptom
Possible Cause
Corrective Action
4. Pilot sparks, but Pilot will
not light.
A. Gas supply.
Verify that incoming gas line shutoff valve is “open”. Verify that inlet
pressure reading is within acceptable limits.
B. Ignitor gap is incorrect.
Verify that spark gap from ignitor to pilot hood is .17 in. or 1/8 in (3
mm).
C. Module is not grounded.
Verify black ground wire from module wire harness is grounded to
metal chassis of appliance.
D. Module voltage output is low.
Verify battery voltage is at least 4 volts. Replace batteries if
voltage is below 4.
5. Pilot lights but continues
to spark, and burner will
not ignite. (If the pilot
continues to spark after
the pilot
fl
ame has been lit,
fl
ame recti
fi
cation has not
occurred.)
A. A shorted or loose connection
in
fl
ame sensing rod.
Verify all connections to wiring diagram in manual. Verify
connections underneath pilot assembly are tight. Verify
connections are not grounding out to metal chassis, pilot burner,
pilot enclosure or screen if present, or any other metal object.
B. Poor
fl
ame recti
fi
cation or
contaminated
fl
ame sensing
rod.
Verify correct pilot ori
fi
ce is installed and gas inlet is set to
pressure speci
fi
cations. Check pilot for soot. Clean if necessary.
C. Module is not grounded.
Verify module is securely grounded to metal chassis of appliance.
Verify that wire harness is
fi
rmly connected to the module.
D. Damaged pilot assembly or
contaminated
fl
ame sensing
rod.
Verify that ceramic insulator around the
fl
ame sensing rod is not
cracked, damaged, or loose. Verify connection from
fl
ame sensing
rod to white sensor wire. Polish
fl
ame sensing rod with
fi
ne steel
wool to remove any contaminants that may have accumulated on
fl
ame sensing rod. Verify continuity with a multimeter with ohms
set at lowest range. Replace pilot if any damage is detected.
E. Module.
Turn ON/OFF rocker switch or wall switch to OFF position.
Remove ignitor wire “I” from module. Place ON/OFF rocker switch
or wall switch in ON position. If there is no spark at “I” terminal
module must be replaced. If there is a spark at “I” terminal, module
is
fi
ne.
6. No pilot, no burner
fl
ame;
3 Flashes on the Module
Red LED.
A. False
fl
ame detected.
Shut off gas and power immediately and call a technician.