6 |
P a g e
CF
-
SPARKER
Installation
Gas
Connections
Locate CF-SPARKER inside of crystal fire burner box.
Remove CF-SPARKER cap and hex nut. Insert AAA battery (not included)
with + end out.
Install CF-SPARKER into control panel as shown below.
Depress CF-SPARKER button to test your sparker.
Locate and orient
sparker box on
control panel as
shown. Sparker box
must be installed
before burner valve.
Using 2 wrenches, disconnect VCSV valve from flex line.