42448 The Wave Burner Series REV B 8-2-16
F. Gas Setup for Natural Gas
1.
With burner in place in Outdoor GreatRoom
Company fire pit table or other installation
location and proper sized orifice inserted in
burner neck (see chart on p.4 for natural gas
orifice sizing), adjust air shutter to a closed
position (as shown at right, no light visible
through the shutter) by loosening the small
screw on the air shutter and rotating it to a
closed position and re-tightening screw.
2.
Attach the natural gas supply line to gas supply
input fitting on the gas valve. If using the
supplied key valve (recommended), this will be
the fitting labeled “Gas supply” in the diagram
at right. Using two wrenches, one to hold the
valve and one to turn the flare nut fitting.
Tighten securely.
3.
Locate the metal flex hose on burner and
tighten securely to the valve fitting labeled
“Gas line to burner” at right, following the
method described in step 2.
4.
Using two wrenches, check
ALL
connections to
ensure there are no loose fittings.
5.
For natural gas installations, the air shutter
should be fully closed as shown at right for
best flame appearance.
To adjust air shutter, loosen the small
securing screw and rotate air shutter to allow
more or less airflow. Closing the shutter will
produce a more visible flame when using
natural gas
CHECK ENTIRE SYSTEM FOR LEAKS BEFORE OPERATING
Gas supply
Orifices installed here
No opening
visible