F. Gas Setup for Natural Gas 

1.

 

With burner in place in Outdoor GreatRoom 
Company fire pit table or other installation 
location and proper sized orifice inserted in 
burner neck (see chart on p.4 for natural gas 
orifice sizing), adjust air shutter to a closed 
position (as shown at right, no light visible 
through the shutter) by loosening the small 
screw on the air shutter and rotating it to a 
closed position and re-tightening screw.  

2.

 

Attach the natural gas supply line to gas supply 
input fitting on the gas valve. If using the 
supplied key valve (recommended), this will be 
the fitting labeled “Gas supply” in the diagram 
at right. Using two wrenches, one to hold the 
valve and one to turn the flare nut fitting. 
Tighten securely.  

3.

 

Locate the metal flex hose on burner and 
tighten securely to the valve fitting labeled 
“Gas line to burner” at right, following the 
method described in step 2.  

4.

 

Using two wrenches, check 

ALL 

connections to 

ensure there are no loose fittings.  

5.

 

For natural gas installations, the air shutter 
should be fully closed as shown at right for 
best flame appearance.

 

 

 

To adjust air shutter, loosen the small 

securing screw and rotate air shutter to allow 
more or less airflow. Closing the shutter will 
produce a more visible flame when using 
natural gas 

 

 

CHECK ENTIRE SYSTEM FOR LEAKS BEFORE OPERATING 

Gas supply 

Orifices installed here 

No opening 
visible 

Summary of Contents for Crystal Fire Wave Series

Page 1: ...l for WV 56 BLK DIY burner DANGER If you smell gas Shut off gas to the appliance Extinguish any open flame If odor continues keep away from the appliance and immediately call your gas supplier or fire...

Page 2: ...e applies to all models and gas control systems Your new burner will give you years of durable use and trouble free enjoyment Homeowner Reference Information Model name ______________________________...

Page 3: ...ponents 3 FramingandClearances a ClearancetoCombustibles b BurnerDimensions c FramingEnclosureforLP GasSupplySystem 4 SettingupyourBurner a BurnerAssembly b GlassInstallation c IgniterInstallationandG...

Page 4: ...Fire has been tested in accordance with ANSI Z21 97 2014 and CSA 2 41 2014 for Canada and has been listed by Underwriters Laboratory UL for installation and operation as described in these installati...

Page 5: ...ility for and the warranty will be voided by the following actions Installation and use of any damaged components Modification of the burner assembly Installation other than as instructed by the Outdo...

Page 6: ...equate clearance Around air openings For service access Locate appliance away from traffic areas WARNING 72 inches to overhang from top of metal bowl Figure 3 1 Clearances to Combustibles 24 24 SIDE W...

Page 7: ...provided at floor level and shall have a total free area of not less than 1 2 square inch per pound 3 2 sq cm kg of stored fuel capacity and not less than a total free area of 10 square inches 64 5 s...

Page 8: ...mage the quick closing nut and result in a hazardous condition Position the hose out of pathways where people might trip over it or in areas where the hose might be subject to accidental damage B Glas...

Page 9: ...ged into either port on the back side of the sparker 2 A spark wire hangs from the electrode at the end of the burner also above This can be plugged into the remaining open port on the back side of th...

Page 10: ...nection Note Have the gas supply installed in accordance with local building codes if any If not follow ANSI 223 1 Installation should be done by a qualified installer approved and or licensed as requ...

Page 11: ...or GreatRoom Company fire pit table or other installation location and proper sized orifice inserted in burner neck see chart on p 4 for orifice sizing locate your incoming propane supply line or hose...

Page 12: ...ecommended this will be the fitting labeled Gas supply in the diagram at right Using two wrenches one to hold the valve and one to turn the flare nut fitting Tighten securely 3 Locate the metal flex h...

Page 13: ...vice technician Force or attempted repair may result in a fire or explosion D Do not use the appliance if any part has been underwater Immediately call a qualified service technician to inspect the ap...

Page 14: ...o NOT obstruct combustion and ventilation air Do NOT place combustible items on top of or near appliance Keep furniture draperies away from appliance Do NOT use lantern fuel kerosene charcoal lighter...

Page 15: ...nd cools down similar to the sound produced by a furnace or heating duct This noise does not affect the operation or longevity of the appliance Do nothing 5 Decorative Beads cracking or splitting A He...

Page 16: ...bris and is in correct position for the gas type being used 5 Inspect orifice for soot dirt or corrosion 6 Verify manifold and inlet pressures Adjust regulator as required WARNING It is imperative the...

Page 17: ...IFOLD 1 5 16 1 2 Flex line 1 2 Female to Female T200 9898 16 1 6 22 1 2 Flex line 1 2 Female to Female T200 9898 22 1 7 Flare cross 1 2 Male to Male 152 8 1 9 Black key valve control panel KV CP BLK 1...

Page 18: ...or any component has been removed repaired or replaced before The Outdoor GreatRoom Company has been afforded a reasonable opportunity to inspect the Product This warranty is limited to the replaceme...

Reviews: