Trouble Shooting Guide
Page 15 of 17
SUDDEN DROP IN GAS PRESSURE OR FLAMES BLOW OUT
1.
Out of gas.
R
eplace the propane tank.
2.
Turn off all
burners, wait 30 seconds, and relight griddle. If problem persists, turn off all
burners.
Disconnect regulator from tank. Wait 10 minutes. Reconnect regulator and perform
the Leak
test. Slowly turn on the propane tank and relight griddle. Other ways the flow
limiting device
can be activated include:
3. Wind could be blowing out your burners. Turn front of griddle of face wind or move out
of the wind.
BURNER WILL NOT LIGHT
IRREGULAR FLAME OR YELLOW FLAME
1. Replace the propane tank.
2. Regulator is not properly seated into the tank valve. Remove and reattach. Hand tighten only.
3. Regulator failure. Order replacement part and replace.
4. Blockage in the gas system. Remove insects,spider webs or other blockage . Clean if
necessary
.Inspect under the control panel to be sure the burners are aligned properly with the
valves.
1. New burner may have residual oil, which will burner off.
2.Tubes in burners are blccked. Remove and clean.
3.Burners have grease or dirt build-up. Remove and clean.
4. Burners are not aligned properly with the valves. Adjust under the control panel.