background image

PV DISCONNECT

AFCI SELF TEST

AFCI ANNUNCIATOR

Specifications

900-0238-01-00 REV B

 

©2018 OutBack Power.  All Rights Reserved.

The RSD-AFCI works in conjunction with the FLEXmax 100 charge controller.  It allows a system to meet the 
2014 National Electric Code requirements for PV systems. 

Features:

o

End-to-end solution listed to UL1741 with PV rapid shutdown equipment (PVRSE)

o

Type 3R enclosures rated for indoor or outdoor installation

o

Flexible design — install the combiner box vertically or horizontally and mount to racking or under an array

o

Interoperability with compatible third-party PV rapid shutdown devices (PVRSE with dry contact)

Components Included:

o

Combiner Box



FWPV6-FH600-SDA

o

Rapid Shutdown Initiator Box



RSI

Listings

o

UL1741



including PVRSE

o

UL1699B

o

CSA C22.2



including PVRSE

Compliance

o

FCC Part 15, Class B

NOTES

:



The DC input and output circuits
are isolated from the enclosure.  



The photovoltaic system grounding shall be
installed according to the requirements of Sections 
690.41 through 690.47 of the National Electric 
Code (ANSI/NFPA 70). The installer is responsible 
for all system grounding.  



Use only UL514B-compliant wet location or
rain-tight conduit hubs for entry into the enclosure. 

Specifications

Rapid Shutdown Solution (RSD-AFCI) 

Quick Start Guide

Dimensions

 19.5" (49.5 cm) 

13.75" 

(34.9 cm)

4.5" 

(11.4 cm)

15.5" 

(39.4 cm)

11.3" 

(28.7 cm)

12.0" 

(30.5 cm)

14.75" 

(37.5 cm)

7.3” (18.5 cm)

6.6” (17.8 cm)

5.0” (12.7 cm)

14.1" 

(35.8 cm)

Accessories Available: 

o

Box of (10) 15A Fuses



FUSE-15-600VDC

o

Box of (10) 20A Fuses



FUSE-20-600VDC

o

30A, 1000 Vdc Fuse Holder



FH-30-1000VDC-DIN

 

5.75" (14.6 cm)

with feet 

fully extended

3.75” (9.5 cm)

2"

½” 

and 

¾” 

½”

All ½”

Combiner

600 Vdc

64 Adc

24 Vdc ± 3%

(6) 600 Vdc DIN rail

fuse holders

0.10 Adc

UL Type 3R

–25 to 60°C

Arc Fault

2", ½”, ¾”

RSI

24 Vdc ± 3%

N/A

24 Vdc ± 3%

N/A

0.06 Adc

UL Type 3R

–25 to 60°C

S

OLAR

 O

N

S

OLAR

 O

FF

 

A

FCI

½”

Device

Voltage

Total Current

DC Input

Overcurrent 

Protection

Power Draw

Enclosure Rating

Ambient Temp.

LED indicators

Knockouts

Up to 6 PV input 
strings per combiner

Controls up to 6 combiner boxes 

Compatibility

  

IMPORTANT 

An isolated Class 2 DC power supply with the following 
specifications must be used to power the RSI:  



24 Vdc ± 3% maximum over input voltage, ambient
temperature, output load, and initial accuracy



Up to 1.5 Adc

Combiner

LED 

indicators

Lockable

rapid shutdown

switch

RSI

  

IMPORTANT 

This document is for use by qualified personnel familiar with photovoltaic (PV) systems.  

Users of this document should meet all local and governmental code requirements for 

licensing and training for the installation of electrical power systems with AC and DC voltage 
up to 600 volts.  This product is only serviceable by qualified personnel

.

FLEXmax 100 

Adjustable mounting feet

Lockable PV disconnect

Lockable latch

Arc fault test button

AFCI annunciator

Securing Screw