PV DISCONNECT
AFCI SELF TEST
AFCI ANNUNCIATOR
Specifications
900-0238-01-00 REV B
©2018 OutBack Power. All Rights Reserved.
The RSD-AFCI works in conjunction with the FLEXmax 100 charge controller. It allows a system to meet the
2014 National Electric Code requirements for PV systems.
Features:
o
End-to-end solution listed to UL1741 with PV rapid shutdown equipment (PVRSE)
o
Type 3R enclosures rated for indoor or outdoor installation
o
Flexible design — install the combiner box vertically or horizontally and mount to racking or under an array
o
Interoperability with compatible third-party PV rapid shutdown devices (PVRSE with dry contact)
Components Included:
o
Combiner Box
FWPV6-FH600-SDA
o
Rapid Shutdown Initiator Box
RSI
Listings
o
UL1741
including PVRSE
o
UL1699B
o
CSA C22.2
including PVRSE
Compliance
o
FCC Part 15, Class B
NOTES
:
The DC input and output circuits
are isolated from the enclosure.
The photovoltaic system grounding shall be
installed according to the requirements of Sections
690.41 through 690.47 of the National Electric
Code (ANSI/NFPA 70). The installer is responsible
for all system grounding.
Use only UL514B-compliant wet location or
rain-tight conduit hubs for entry into the enclosure.
Specifications
Rapid Shutdown Solution (RSD-AFCI)
Quick Start Guide
Dimensions
19.5" (49.5 cm)
13.75"
(34.9 cm)
4.5"
(11.4 cm)
15.5"
(39.4 cm)
11.3"
(28.7 cm)
12.0"
(30.5 cm)
14.75"
(37.5 cm)
7.3” (18.5 cm)
6.6” (17.8 cm)
5.0” (12.7 cm)
14.1"
(35.8 cm)
Accessories Available:
o
Box of (10) 15A Fuses
FUSE-15-600VDC
o
Box of (10) 20A Fuses
FUSE-20-600VDC
o
30A, 1000 Vdc Fuse Holder
FH-30-1000VDC-DIN
5.75" (14.6 cm)
with feet
fully extended
3.75” (9.5 cm)
2"
½”
and
¾”
½”
All ½”
Combiner
600 Vdc
64 Adc
24 Vdc ± 3%
(6) 600 Vdc DIN rail
fuse holders
0.10 Adc
UL Type 3R
–25 to 60°C
Arc Fault
2", ½”, ¾”
RSI
24 Vdc ± 3%
N/A
24 Vdc ± 3%
N/A
0.06 Adc
UL Type 3R
–25 to 60°C
S
OLAR
O
N
S
OLAR
O
FF
A
FCI
½”
Device
Voltage
Total Current
DC Input
Overcurrent
Protection
Power Draw
Enclosure Rating
Ambient Temp.
LED indicators
Knockouts
Up to 6 PV input
strings per combiner
Controls up to 6 combiner boxes
Compatibility
IMPORTANT
An isolated Class 2 DC power supply with the following
specifications must be used to power the RSI:
24 Vdc ± 3% maximum over input voltage, ambient
temperature, output load, and initial accuracy
Up to 1.5 Adc
Combiner
LED
indicators
Lockable
rapid shutdown
switch
RSI
IMPORTANT
This document is for use by qualified personnel familiar with photovoltaic (PV) systems.
Users of this document should meet all local and governmental code requirements for
licensing and training for the installation of electrical power systems with AC and DC voltage
up to 600 volts. This product is only serviceable by qualified personnel
.
FLEXmax 100
Adjustable mounting feet
Lockable PV disconnect
Lockable latch
Arc fault test button
AFCI annunciator
Securing Screw