Specifications
62
900-0209-01-00 Rev A
Default Settings and Ranges
The settings in this table are as shown in the system display.
Table 12
FLEXmax Settings
Mode Menu
Item
Setting
Value 24-volt 36-volt 48-volt
Charger
Absorb Voltage
Default
28.8 Vdc
43.2 Vdc
57.6 Vdc
Range
Float
setting to 68.0 Vdc
(Absorb) Time
Default
01.0 hours
Range
00.0 to 24 hours
Float
Default
27.6 Vdc
41.4 Vdc
55.2 Vdc
Range
20.0 Vdc to
Absorbing
setting
Rebulk Voltage
Default
24.0 Vdc
36.0 Vdc
48.0 Vdc
Range
10.0 Vdc to
Float
setting
Current Limit
Default
100 Adc
Range
5 to 100 Adc
Absorb End Amps
Default
00 Adc
Range
00 to 55 Adc
MPPT
MPPT Mode
Default
<
Auto
>
Range
<
Auto
>
or
U-Pick
>
U-Pick VOC
Default
77% Voc
Range
40 to 90% Voc
Wakeup VOC Change
Default
3.0 Vdc
4.5 Vdc
6.0 Vdc
Range
1.5 to 9.5 Vdc
(Wakeup VOC) Time
Default
05 minutes
Range
05 to 15 minutes
Snooze Mode Amps
Default
0.6 Adc
Range
0.2 to 1.0 Adc
Temperature
Compensation
Mode
Default
<
Wide
>
Range
<
Wide
>
or
<
Limited
>
Slope
Default
5 mV
Range
2 to 6 mV
Lower Battery Voltage
Default
26.4 Vdc
39.6 Vdc
52.8 Vdc
Range
10 Vdc to
Upper Battery Voltage
setting
Upper Battery Voltage
Default
28.2 Vdc
42.3 Vdc
56.4 Vdc
Range
Lower Voltage
setting to 68.0 Vdc
Battery
Equalize
Equalization Voltage
Default
28.8 Vdc
43.2 Vdc
57.6 Vdc
Range
Absorb Voltage
setting to 68.0 Vdc
(Equalization) Hours
Default
01 hours
Range
1 to 7 hours
Automatic Battery
Equalization
Default
0 days
Range
0 to 250 days
Grid-Tie Mode
Enable Grid-Tie Mode
Default
N
Range
Y
or
N
Auxiliary
Output
Vent Fan
Default
<
Off
>
Range
<
On
,
Auto
,
Off
>
Enable
Voltage
Default
28.8 Vdc
43.2 Vdc
57.6 Vdc
Range
20.0 to 68.0 Vdc
PV Trigger
Default
<
Off
>
Range
<
On
,
Auto
,
Off
>
Active
Default
Active High
Range
Active High
or
Active Low
Enable
Voltage
Default
24.0 Vdc
Range
20 to 250 Vdc
Hold
Time
Default
0 Vdc
Range
0 to 25 seconds