Updating Firmware
54
900-0209-01-00 Rev A
3. Download the latest firmware revision as noted on page 53. Transfer the files to the microSD card.
4. If the file called
FN100-00.bin
was previously present on the card, delete it and replace it with the
downloaded file with that name. This file needs to be in the root directory, not in a separate folder.
5. Before removing the card from the computer it is recommended to eject it using the computer’s
onscreen
Eject
command (usually titled
Safely Remove Hardware
,
Eject Media
, etc.).
6. Insert the card back into the FLEXmax 100. Ensure it clicks into position similarly to the way it was
previously removed.
NOTE
: The following steps require access to the controller and battery disconnect at the same time.
Two people may be needed.
7. Press and hold the
R
ESET
button with a nonconductive narrow tool. (See Figure 50. The button is
recessed inside the hole by several millimeters.)
8. While still pressing the
R
ESET
button, turn the battery disconnect to the
O
N
position.
9. Still
pressing
the
R
ESET
button, watch the LED indicators on the FLEXmax 100. (See Figure 51.)
When the
S
TATUS
LED indicator flashes green rapidly, the programming process has started. It is
safe to release the button.
Figure 51 Status Indicator
10. Within a few seconds the
S
TATUS
indicator will begin flashing red instead of green. After
approximately 10 seconds it will flash red more quickly.
11. When the update process is complete, all LED indicators will flash in sequence as in a standard
power-up routine. The internal fan will run briefly.
The firmware update process is complete.