background image

Operation 

 

14

 

900-0138-01-00 Rev

 A 

 

 

To update the firmware using an FTP site and the SD Card: 

1.

 

Connect to the AXS Port using the FTP site.  

2.

 

Copy the update file from the OutBack website to the UPDATEFW directory on the microSD card.   

NOTE

:  It may be necessary to create this directory on the SD card first, using the FTP client.  

3.

 

Once the update file is copied, disconnect the FTP client from the AXS Port. 

4.

 

The AXS Port will detect the disconnection of the FTP client and will automatically update the 
firmware if the correctly named file is found in the UPDATEFW directory.  After a successful 
firmware update, the update file will be erased from the UPDATEFW directory. 

Email Functions  

The AXS Port can send email messages with alarms or other status reports.  To enable the email 
function in the AXS Port, certain fields in the OutBack block must be set up using Modbus client 
software.  (See Table 1 on page 8.) 

Table 4          Email Setup

 

Field Value 

OutBack_SMTP_Server_Name

 

Email account name, such as 

outbackpower.com

 

OutBack_SMTP_Account_Name

 

Name of SMTP server for sending mail, such as 

smtp.gmail.com

 

OutBack_SMTP_Account_Name  

 

Email account name, such as 

outbackpower.com

 

OutBack_SMTP_Email_User_Name  

 

Email user name, such as 

[email protected]

 

OutBack_SMTP_Email_Password

 

Email user account password, such as 

mypassword

 

OutBack_Status_Email_Subject_Line

 

Status email subject line text

 

OutBack_Status_Email_To_Address_1

 

First recipient address

 

OutBack_Status_Email_To_Address_2

 

Second recipient address

 

OutBack_Status_Email_Interval

 

Number of hours between status email (1-23)  

NOTE

:  0 = status email disabled

 

OutBack_Status_Email_Status_Time

 

First hour within day that status email will be sent (0-23)

 

           

Messages will be sent to the designated recipient addresses starting at the time indicated, and 
repeating at the appropriate interval.   

For example, if 

OutBack_Status_Email_Status_Time

 is set to 10 and 

OutBack_Status_Email_Interval

 

is set to 4, then a status email will be sent at 10 AM, 2 PM, 6 PM, and 10 PM. 

 

Summary of Contents for AXS Port

Page 1: ...e directamente a un solo dispositivo o a varios por medio de los componentes de administraci n de comunicaciones HUB4 o HUB10 de OutBack La AXS Port permite crear interfaces de usuario a medida para s...

Page 2: ...NTP Puertos HUB Dispositivo RJ 45 Comunicaciones RJ 45 Sensor de temperatura RJ 11 Protocolo de comunicaci n Modbus TCP seg n est ndar SunSpec Interfaz de dispositivo de OutBack Exclusivo de OutBack...

Page 3: ...AXS Port SunSpec Modbus Interface Owner s Manual...

Page 4: ...Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING OUTBACK POWER TECHNOLOGIES a MAKES NO WARRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS M...

Page 5: ...Card Logging 12 Data Log File Format 12 FTP Access to Logs 13 Firmware Updates 13 Email Functions 14 Troubleshooting 15 Basic Troubleshooting 15 Error Codes 15 Specifications 17 Regulatory Specificati...

Page 6: ...igure 1 Features 3 Figure 2 Wall Mount 5 Figure 3 DIN Rail Mount 5 Figure 4 Cabling 6 Figure 5 Accessories 6 Figure 6 LED Indicators 7 Figure 7 Reset Switch 7 Figure 8 Data Log Example for the System...

Page 7: ...tBack products NOTE This product is for use instead of a system display such as the MATE3 OutBack does not support the use of the AXS Port and a system display at the same time Audience This manual is...

Page 8: ...rmware updates The AXS Port can be equipped with a clip for mounting on a DIN rail This clip is included The AXS Port can be equipped with an additional temperature sensor to supplement the battery se...

Page 9: ...rail Hook the upper edge of the clip over the DIN rail 3 Press on the lower edge to bend it Slide the clip over the DIN rail and snap into place Release the clip once the device is securely in place...

Page 10: ...D Card LED will illuminate See Figure 6 Micro SD Card Slot Temperature Sensor Port NOTE Orient the microSD card with the conductors facing down The angled corner enters on the right of the slot OutBac...

Page 11: ...et switch is recessed to avoid being accidentally pressed Insert a paper clip wire or similar narrow tool The switch should be held for five seconds The Fault LED will blink during the resetting proce...

Page 12: ...f field data or a fixed value where applicable Description Describes the field data SunSpec Block Structure The first block is the Common Block which supplies vendor and model information for the devi...

Page 13: ...W OutBack_Status_Email_To _Address_2 String 40 N A N A Programmable Status Email to Address 2 165 165 1 R W OutBack_Alarm_Email_ Enable uint16 Enumerated N A Programmable 0 Disabled 1 Enabled 166 190...

Page 14: ...Volts N A Measured Highest VOC today 18 18 1 R CC_Todays_kWH uint16 KWH KWH _SF Measured Daily accumulated kilowatt hours output 19 19 1 R CC_Todays_AH uint16 AH AH_SF Measured Daily accumulated amp...

Page 15: ...config_Wakeup_VOC uint16 Volts Voltage _SF Programmable Voc change which causes Wakeup occurs 29 29 1 R W CCconfig_Snooze_Mode_ Amps uint16 Amps Voltage _SF Programmable Snooze Mode Amps 30 30 1 R W C...

Page 16: ...nt16 Mins N A Read Only Data Log Float Time Minutes 61 61 1 R CCconfig_Data_Log_Daily_ Min_Batt_Volts uint16 Volts Voltage _SF Read Only Data Log minimum daily battery voltage 62 62 1 R CCconfig_Data_...

Page 17: ...nsert the SD card into the slot on the AXS Port 3 Disconnect any OutBack device cable from the AXS Port 4 Using a narrow tool press and hold the reset switch Reconnect the OutBack device cable The amb...

Page 18: ...age 8 Table 4 Email Setup Field Value OutBack_SMTP_Server_Name Email account name such as outbackpower com OutBack_SMTP_Account_Name Name of SMTP server for sending mail such as smtp gmail com OutBack...

Page 19: ...ve card Insert the card firmly or replace the card Fault LED illuminates OutBack_error field in OutBack block is occupied by an error code Check for error codes Time based functions are incorrect foll...

Page 20: ...Troubleshooting 16 900 0138 01 00 Rev A THIS PAGE INTENTIONALLY LEFT BLANK...

Page 21: ...c standard OutBack Device Interface OutBack Proprietary PC Interface 10 100 Ethernet Mounting DIN clip provided or surface mounting Environmental Rating Indoor Type 1 IP 30 non condensing AXS Port 40...

Page 22: ...North America 5917 195th St NE Arlington WA 98223 USA 1 360 435 6030 900 0138 01 00 Rev A...