background image

Operation 

 

12

 

900-0138-01-00 Rev

 A 

 

 

Table 3          Charge Controller Configuration Block

 

Start End Size R/W Name 

Type 

Units 

Scale 
Factor Contents 

Description 

48 48 1  R/W 

CCconfig_AUX_Divert_ 
Relative_Volts 

int16 Volts 

Voltage
_SF 

Programmable AUX Divert Relative Volts 

49 49 1  R/W 

CCconfig_AUX_Divert_ 
Hyst_Volts uint16 

Volts 

Voltage
_SF 

Programmable AUX Divert Hyst Volts 

50 50 1  R 

CCconfig_Major_Firmware
_Number 

uint16 

N/A 

N/A 

Read Only 

Charge Controller Major firmware revision 

51 51 1  R 

CCconfig_Mid_Firmware_ 
Number 

uint16 

N/A 

N/A 

Read Only 

Charge Controller Mid firmware revision 

52 52 1  R 

CCconfig_Minor_Firmware
_Number 

uint16 

N/A 

N/A 

Read Only 

Charge Controller Minor firmware revision 

53 53 1  W 

CCconfig_Set_Data_Log_ 
Day_Offset 

uint16 Days 

N/A  Write 

Only  Day 

offset 0-128, 0 =Today, 1 = -1 day … 

54 54 1  R 

CCconfig_Get_Current_ 
Data_Log_Day_Offset 

uint16 Days 

N/A  Read 

Only  Current Data Log Day Offset 

55 55 1  R 

CCconfig_Data_Log_Daily_
AH 

uint16 

AH 

AH_SF 

Read Only 

Data Log AH 

56 56 1  R 

CCconfig_Data_Log_Daily_
kWH 

uint16 KWH 

KWH 
_SF 

Read Only 

Data Log kWH 

57 57 1  R 

CCconfig_Data_Log_Daily_
Max_Output_Amps 

uint16 Amps 

Voltage
_SF 

Read Only 

Data Log maximum Output Amps 

58 58 1  R 

CCconfig_Data_Log_Daily_
Max_Output_Watts 

uint16 Watts 

Power_
SF 

Read Only 

Data Log maximum Output Wattage 

59 59 1  R 

CCconfig_Data_Log_Daily_
Absorb_Time 

uint16 Mins 

N/A  Read 

Only  Data Log Absorb Time Minutes 

60 60 1  R 

CCconfig_Data_Log_Daily_
Float_Time 

uint16 

Mins 

N/A 

Read Only 

Data Log Float Time Minutes 

61 61 1  R 

CCconfig_Data_Log_Daily_
Min_Batt_Volts 

uint16 Volts 

Voltage
_SF 

Read Only 

Data Log minimum daily battery voltage 

62 62 1  R 

CCconfig_Data_Log_Daily_
Max_Batt_Volts 

uint16 Volts 

Voltage 
_SF 

Read Only 

Data Log maximum daily battery voltage 

63 63 1  R 

CCconfig_Data_Log_Daily_
Max_Input_Volts 

uint16 

Volts 

N/A 

Read Only 

Data Log maximum daily input voltage 

64 64 1  R 

CCconfig_Clear_Data_Log_
Read 

uint16 

N/A 

N/A 

Read Old 

Read value needed to clear data log 

65 65 1  W 

CCconfig_Clear_Data_Log_
Write_Complement uint16 

N/A  N/A 

Write 

Only 

Write value's complement to clear data log (not 
Implemented) 

SD Card Logging 

The AXS Port records operational status information about the system.  It will record data to the 
microSD card up to the limit of the card.  (It has been tested with microSD cards up to 8 GB.)  The 
interval for automatic downloading to the microSD card can be set at intervals from 1 to 60 seconds.  
This setting is made in the 

Outback_SD_Card_Data_ Log_Write_Interval

 field.  The default setting is 

0 (disabled). 

If the card’s capacity is exceeded, the data will begin to be overwritten starting with the oldest first. 

Data Log File Format 

As noted on page 8, each OutBack product exports data in comma-separated ASCII strings. 

Information generated by this function will be saved on the SD card in a generic

 .csv 

file format, which 

can be read by most spreadsheet programs.  The file name on the 

.csv

 file will appear as follows: 

Example

:  11062722.csv (YYMMDDHR.csv) 

Where

:  YY = Last 2 digits of the year, MM = Month (01-12), DD = Day (01-31), HR = Hour (00-23) 

Examples of data logs are shown on the next page. 

Summary of Contents for AXS Port

Page 1: ...e directamente a un solo dispositivo o a varios por medio de los componentes de administraci n de comunicaciones HUB4 o HUB10 de OutBack La AXS Port permite crear interfaces de usuario a medida para s...

Page 2: ...NTP Puertos HUB Dispositivo RJ 45 Comunicaciones RJ 45 Sensor de temperatura RJ 11 Protocolo de comunicaci n Modbus TCP seg n est ndar SunSpec Interfaz de dispositivo de OutBack Exclusivo de OutBack...

Page 3: ...AXS Port SunSpec Modbus Interface Owner s Manual...

Page 4: ...Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING OUTBACK POWER TECHNOLOGIES a MAKES NO WARRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS M...

Page 5: ...Card Logging 12 Data Log File Format 12 FTP Access to Logs 13 Firmware Updates 13 Email Functions 14 Troubleshooting 15 Basic Troubleshooting 15 Error Codes 15 Specifications 17 Regulatory Specificati...

Page 6: ...igure 1 Features 3 Figure 2 Wall Mount 5 Figure 3 DIN Rail Mount 5 Figure 4 Cabling 6 Figure 5 Accessories 6 Figure 6 LED Indicators 7 Figure 7 Reset Switch 7 Figure 8 Data Log Example for the System...

Page 7: ...tBack products NOTE This product is for use instead of a system display such as the MATE3 OutBack does not support the use of the AXS Port and a system display at the same time Audience This manual is...

Page 8: ...rmware updates The AXS Port can be equipped with a clip for mounting on a DIN rail This clip is included The AXS Port can be equipped with an additional temperature sensor to supplement the battery se...

Page 9: ...rail Hook the upper edge of the clip over the DIN rail 3 Press on the lower edge to bend it Slide the clip over the DIN rail and snap into place Release the clip once the device is securely in place...

Page 10: ...D Card LED will illuminate See Figure 6 Micro SD Card Slot Temperature Sensor Port NOTE Orient the microSD card with the conductors facing down The angled corner enters on the right of the slot OutBac...

Page 11: ...et switch is recessed to avoid being accidentally pressed Insert a paper clip wire or similar narrow tool The switch should be held for five seconds The Fault LED will blink during the resetting proce...

Page 12: ...f field data or a fixed value where applicable Description Describes the field data SunSpec Block Structure The first block is the Common Block which supplies vendor and model information for the devi...

Page 13: ...W OutBack_Status_Email_To _Address_2 String 40 N A N A Programmable Status Email to Address 2 165 165 1 R W OutBack_Alarm_Email_ Enable uint16 Enumerated N A Programmable 0 Disabled 1 Enabled 166 190...

Page 14: ...Volts N A Measured Highest VOC today 18 18 1 R CC_Todays_kWH uint16 KWH KWH _SF Measured Daily accumulated kilowatt hours output 19 19 1 R CC_Todays_AH uint16 AH AH_SF Measured Daily accumulated amp...

Page 15: ...config_Wakeup_VOC uint16 Volts Voltage _SF Programmable Voc change which causes Wakeup occurs 29 29 1 R W CCconfig_Snooze_Mode_ Amps uint16 Amps Voltage _SF Programmable Snooze Mode Amps 30 30 1 R W C...

Page 16: ...nt16 Mins N A Read Only Data Log Float Time Minutes 61 61 1 R CCconfig_Data_Log_Daily_ Min_Batt_Volts uint16 Volts Voltage _SF Read Only Data Log minimum daily battery voltage 62 62 1 R CCconfig_Data_...

Page 17: ...nsert the SD card into the slot on the AXS Port 3 Disconnect any OutBack device cable from the AXS Port 4 Using a narrow tool press and hold the reset switch Reconnect the OutBack device cable The amb...

Page 18: ...age 8 Table 4 Email Setup Field Value OutBack_SMTP_Server_Name Email account name such as outbackpower com OutBack_SMTP_Account_Name Name of SMTP server for sending mail such as smtp gmail com OutBack...

Page 19: ...ve card Insert the card firmly or replace the card Fault LED illuminates OutBack_error field in OutBack block is occupied by an error code Check for error codes Time based functions are incorrect foll...

Page 20: ...Troubleshooting 16 900 0138 01 00 Rev A THIS PAGE INTENTIONALLY LEFT BLANK...

Page 21: ...c standard OutBack Device Interface OutBack Proprietary PC Interface 10 100 Ethernet Mounting DIN clip provided or surface mounting Environmental Rating Indoor Type 1 IP 30 non condensing AXS Port 40...

Page 22: ...North America 5917 195th St NE Arlington WA 98223 USA 1 360 435 6030 900 0138 01 00 Rev A...

Reviews: