900-0137-01-00 Rev

 A 

13

 

Charge Controller Data Stream 

This is the data stream generated for each OutBack charge controller connected to the system.   

 

The data stream for each charge controller is 52 characters long.   

 

An example is 00,3,00,08,06,034,031,00,05,000,02,262,000,000,045.   

 

The items shown in Table 14 define the data stream by character.  Specific descriptions for each category 
begin on

 

page 14. 

Table 14 

Data Stream Matrix for Charge Controller 

 

 

Character Definition 

Character

Definition 

New Line character, ASCII (10).   
Denotes the start of the status page. 

27 

High digit of AUX mode. 

Tens digit of Port number. 

28 

Low digit of AUX mode. 

Units digit of Port number. 

29 

Comma, ASCII (44).  Used as a data separator. 

Comma, ASCII (44).  Used as a data separator. 

30 

High digit of charge controller Fault code. 

Device type 3, ASCII (51).  Indicates charge 
controller.  

31 

Middle digit of charge controller Fault code. 

Comma, ASCII (44).  Used as a data separator. 

32 

Low digit of charge controller Fault code. 

Unused, ASCII (48). 

33 

Comma, ASCII (44).  Used as a data separator. 

Unused, ASCII (48). 

34 

High digit of Charger mode. 

Comma, ASCII (44).  Used as a data separator. 

35 

Low digit of Charger mode. 

10 

Tens digit of Charger current. 

36 

Comma, ASCII (44).  Used as a data separator. 

11 

Units digit of Charger current. 

37 

Tens digit of battery voltage. 

12 

Comma, ASCII (44).  Used as a data separator. 

38 

Units digit of battery voltage. 

13 

Tens digit of PV current. 

39 

Tenths digit of battery voltage. 

14 

Units digit of PV current. 

40 

Comma, ASCII (44).  Used as a data separator. 

15 

Comma, ASCII (44).  Used as a data separator. 

41 

Thousands digit of daily amp-hour accumulation. 

16 

Hundreds digit of PV input voltage. 

42 

Hundreds digit of daily amp-hour accumulation. 

17 

Tens digit of PV input voltage. 

43 

Tens digit of daily amp-hour accumulation. 

18 

Units digit of PV input voltage. 

44 

Units digit of daily amp-hour accumulation. 

19 

Comma, ASCII (44).  Used as a data separator. 

45 

Comma, ASCII (44).  Used as a data separator. 

20 

Hundreds digit of daily kilowatt-hour harvest. 

46 

Unused, ASCII (48). 

21 

Tens digit of daily kilowatt-hour harvest. 

47 

Unused, ASCII (48). 

22 

Units digit of daily kilowatt-hour harvest. 

48 

Comma, ASCII (44).  Used as a data separator. 

23 

Comma, ASCII (44).  Used as a data separator. 

49 

Hundreds digit of Checksum. 

24 

Unused, ASCII (48). 

50 

Tens digit of Checksum. 

25 

Tenths digit of Charger current (not used on MX60). 

51 

Units digit of Checksum. 

26 

Comma, ASCII (44).  Used as a data separator. 

52 

Carriage return, ASCII (13).   
Denotes the end of the status page. 

 

Star

t o

f St

atus

 Pa

ge 

Por

t A

ddr

ess 

separ

at

or

 

D

e

vi

ce Type 

separ

at

or

 

unus

ed 

separ

at

or

 

C

har

ger

 cur

re

nt 

separ

at

or

 

PV cur

re

n

separ

at

or

 

PV vol

tage 

separ

at

or

 

Da

ily kilo

wa

tt-h

o

u

rs 

separ

at

or

 

C

har

ger

 cur

re

nt 

tent

hs 

separ

at

or

 

AU

X m

o

de 

separ

at

or

 

E

rro

r co

d

e

separ

at

or

 

C

hager

 m

o

de 

separ

at

or

 

Batt

ery volta

g

separ

at

or

 

D

a

ily

 am

p-

hour

separ

at

or

 

unus

ed 

separ

at

or

 

Checksum 

End 

of st

atus

 pa

ge 

ASCII 

code 

10 X X 44 51 44 48 48 44 X  X 44 X  X 44 X  X  X 44 X X X 44 48 X 44 X X 44 X X X 44 X X 44 X X X 44 X  X  X  X 44 48 48 44 X X X 13

Char.  1  2  3  4  5  6  7  8  9  10 11  12  13 14  15  16 17 18  19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44  45  46 47 48 49 50 51 52

Summary of Contents for MATE3

Page 1: ...7 124 9 107 5 7 A b uD h a b i U A E E ma i l s o l a r e mi r a t e s g r e e n c o m We b w w w e mi r a t e s g r e e n a e E mi r a t e s G r e e n E mi r a t e s G r e e nE l e c t r i c a l Me c...

Page 2: ...MATE3 USB Card Owner s Manual...

Page 3: ...WRITING OUTBACK POWER TECHNOLOGIES a MAKES NO WARRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION b ASSUMES NO...

Page 4: ...ol 4 FX Class Inverter Data Stream 5 Definition of Data Stream Items for the FX Class Inverter 6 Radian Class Inverter Data Stream 9 Definition of Data Stream Items for the Radian Class Inverter 11 Ch...

Page 5: ...ers 9 Table 8 Data Stream Definitions for Radian Class Inverters 10 Table 9 Radian Inverter Operating Mode 11 Table 10 Radian Error Codes 12 Table 11 Radian AC Modes 12 Table 12 Radian Misc 12 Table 1...

Page 6: ...card must be installed for this function to work see next page The MATE3 s Serial Data Stream menu item must be set to Enabled in order for it to send data streams See the MATE3 System Display and Co...

Page 7: ...sed from the personal computer to an OutBack device using the MATE3 The data streams sent from an inverter have a different content then those from a charge controller or FLEXnet DC battery monitor ho...

Page 8: ...y current 39 Tenths digit of battery voltage 14 Units digit of Buy current 40 Comma ASCII 44 Used as a data separator 15 Comma ASCII 44 Used as a data separator 41 High byte of inverter Misc 16 Hundre...

Page 9: ...es are shown in Table 2 Inverter Off The user has turned the inverting mode off and no other functions are active Search The inverter is using the Search function of the inverting mode Inverter On The...

Page 10: ...e values are additive For example an overtemp error and backfeed error would return an ASCII value of 132 a binary value of 10000100 AC Modes This represents the status of the AC input The range is 00...

Page 11: ...rs the values are additive For example a low AC input voltage and low AC input frequency would return an ASCII value of 10 a binary value of 00001010 Checksum This is a simple additive checksum of the...

Page 12: ...id input voltage separator L1 Generator input voltage separator L1 output voltage separator Error modes separator L2 Charger current separator L1 Charger current separator L2 Sell Current ASCII code 1...

Page 13: ...s a data separator 58 High digit of inverter Error code 19 Hundreds digit of AC input voltage on grid L1 59 Middle digit of inverter Error code 20 Tens digit of AC input voltage on grid L1 60 Low digi...

Page 14: ...to 99 in 1 ampere increments Inverter Operating Modes Reports any of a variety of functions that can be performed by the inverter The range is 00 to 99 although not all items are in use Items and corr...

Page 15: ...dc for 24 volt systems and 0 4 Vdc for 48 volt systems Misc Byte This is an ASCII expression of an 8 bit binary string displayed in values ranging from 000 to 255 Only certain bits are in use at this...

Page 16: ...current 40 Comma ASCII 44 Used as a data separator 15 Comma ASCII 44 Used as a data separator 41 Thousands digit of daily amp hour accumulation 16 Hundreds digit of PV input voltage 42 Hundreds digit...

Page 17: ...255 Each bit represents a different fault as shown in Table 16 For example a shorted battery sensor would return an ASCII value of 32 a binary value of 00100000 Only certain bits are used In MX60 con...

Page 18: ...f Shunt B current 39 Enable flag for Shunt A 14 Units digit of Shunt B current 40 Enable flag for Shunt B 15 Tenths digit of Shunt B current 41 Enable flag for Shunt C 16 Comma ASCII 44 Used as a data...

Page 19: ...tate of 0 or closed a state of 1 Relay State indicates whether the function has been set to manual mode a state of 0 or automatic mode a state of 1 EXAMPLE A returned value of 009 would indicate that...

Page 20: ...rt Modbus Interface is recommended The AXS Port however can only send individual commands and not universal ones Table 21 Command Response Definitions Command Response INV 0 Inverter Off INV 1 Search...

Page 21: ...ements inverter s AC2 input limit amps AC2INLM Returns inverter s AC2 input limit amps AC2INLM nn BULK 1 Starts system wide bulk charge all ports BULK 2 Stops system wide bulk charge ie goto float all...

Page 22: ...lowatt hours CC 14 Data Stream FLEXmax CC 13 FLEXnet DC Battery Monitor 15 FX Class Inverter 5 Radian Class Inverter 9 Data Stream Definitions FLEXmax CC Aux Mode 14 Battery Voltage 14 Charger Current...

Page 23: ...rrent 11 Sell Enabled 11 Warning Codes 12 Device Type CC 14 FNDC 16 FX 6 Radian 11 E Error Codes FX 7 Radian 12 External Connections 4 Extra Data Identifier FNDC 16 F Fault Codes CC 14 G Generator Inp...

Page 24: ...NOTES...

Page 25: ...900 0137 01 00 Rev A Corporate Headquarters 5917 195th St NE Arlington WA 98223 USA 1 360 435 6030 European Office Hansastrasse 8 D 91126 Schwabach Germany 49 9122 79889 0...

Reviews: