OUMAN GSMMOD10 Quick Start Manual Download Page 7

7

DNA:  
TeliaSonera:
Elisa:           
Saunalahti:  
Tele Finland:

+358447983500
+358405202000
+358508771010
+358451100100
+358405202330

Products: 
EH-60
EH-686

Products: 
EH-203, version 2.18 
EH-105, version 1.75

Detailed instructions for commencing use of the text mes-
sage connection are presented in the ”GSM modem instal-
lation” and ”Protection” sections of the user manual.

Message Centre number:
Change the message centre number to +358447983500.
The message centre number can be changed by a text 
message. Send the message to the control device as fol-
lows:

(EH01=device code, 0000=service code. Note the spaces in the 
message, and that the codes for the device may have changed.)

As of version 2.4.9, the default for the EH-60 device is the DNA 
message centre number.

PIN code:

The PIN code for all program versions of the EH-686 is
0000. For the EH-60, the PIN code used to be 0000, but 
has changed to 1234 as of version 2.4.9 (sold after 1 March 
2008).

The PIN code for the SIM card in the GSM modem must be 
the same as the device PIN code. If necessary, first change 
the SIM card PIN code to 0000. The PIN code can be 
changed by using the card in a GSM phone.

For security reasons, the PIN code should be changed after 
the GSM modem has been installed. This is done by send-
ing the following text message to the EH-60/EH-686:

  
The regulator will send a reply message showing the 
device ID, service code and PIN code. Edit the reply by 
replacing the old code with a new one and send it back to 
the control device. Then make the PIN code of the GSM 
modem’s SIM card identical by using the SIM card in a GSM 
phone.

EH-60/EH-686 device switches

The factory default positions of switches on the EH-60 
are correct. If the EH-686 has been configured using a PC, 
the switch positions may have been changed. In this case, 
check the switch positions:

Required settings for regulator/control device

Go to special regulator maintenance and the
”Text message settings” section:

Message Centre number:

Check that the message centre number set for the regu-
lator is +358447983500.

PIN code:

The factory default PIN code setting for the SIM card 
is 1234. We recommend changing the code for security 
reasons. First install the SIM card in a GSM phone. After 
changing the PIN code, transfer the SIM card to the mo-
dem. Set the same PIN code for the regulator as for the 
SIM card in the GSM modem.

Modem type:

On the regulator, select Ouman/Fargo as the modem type.

Perform start-up or modem initialization with the 

regulator so that it will begin to use the modem:

If the GSM modem is connected to an EH-203 regulator, 
perform the start-up function.
The start-up function is performed by going to the regu-
lator’s Start section, pressing OK and exiting the start-up 
mode with ESC without changing any settings.

If the GSM modem is connected to an EH-105 regulator, 
perform modem initialization.
Initialization is performed by going to the regulator’s 
”modem initialization” section, pressing OK and exiting 
with ESC.

Message Centre number:

EH01 0000 HÄL.NUMEROT: nro5: SANOMAKESKUS  +358447983500

--------------------------------------------------------

EH01 0000 SUOJAUS

-----------------

Product disposal:  

The enclosed marking on the additional material of 

the product indicates that this product must not be 

disposed of together with household waste at the 

end of its life span. The product must be processed 

separately from other waste to prevent damage 

caused by uncontrolled waste disposal to the environment 

and the health of fellow human beings. 

The users must contact the retailer responsible for having 

sold the product, the supplier or a local environmental au-

thority, who will provide additional information on safe recy-

cling opportunities of the product. This product must not be 

disposed of together with other commercial waste.

Switch is in the 
BOTTOM position

Communication mode 
is MODEM + SMS

Summary of Contents for GSMMOD10

Page 1: ...heti k ytt valmis Liittym sis lt yll pito ja k ytt maksun puoleksi vuodeksi max 150 tekstiviesti ylimenevist viesteist laskutetaan erikseen Liittym on m r aikainen ja suljetaan 6 kk n kuluttua pa keti...

Page 2: ...stunut mutta ei liikennett 75ms p ll 75ms pois 75ms p ll 3s pois Yksi tai useampi GPRS yhteys aktivoitunut 500ms p ll 25 ms pois Datapakettien siirto k ynniss P ll jatkuvasti Yhdistetty et yhteydell t...

Page 3: ...n tasap ist ty kalua kuten esimerkiksi tasap ist ruuvimeisseli Jotta tekstiviestiyhteytt voidaan k ytt pit mo deemiin kytketylle laitteelle asettaa SIM kortin PIN koodi Ohjaus s t laitteen PIN koodiks...

Page 4: ...tteet EH 203 versio 2 18 EH 105 versio 1 75 Mene s timen erikoishuoltoon ja siell kohtaan Tekstiviestiasetukset Sanomakeskusnumero Tarkista ett s timelle on asetettu sanomakeskus numeroksi 35844798350...

Page 5: ...ng voltage 8 30VDC Rated current 12V 200mA 24V 130mA Warranty 2 years Optional accessories ANT1 External antenna 900 1800MHz with 2 5 meter cable CE GSM10 Antenna cable extension 10 m Orange LED Modem...

Page 6: ...ps and card is properly attached to slot The SIM card can be removed by using a flat object such as a screwd river with flat head To be able to use the SMS connection the PIN code has to be installed...

Page 7: ...the switch positions Required settings for regulator control device Go to special regulator maintenance and the Text message settings section Message Centre number Check that the message centre numbe...

Page 8: ...ksi M r aikainen GSM L6kk liittym voidaan muuttaa toistaiseksi voimassaolevaksi kestotilausliittym ksi kun liittym asiakas tekee kestotilauksen Oumanille ennen 6 kk n m r ajan umpeutumista Tilaus voi...