8.2 Setting measurement type of the 4 … 20 mA interface to
level or depth measurement
8.3 Scaling the measuring range for the 4 … 20 mA interface
With DIPs 5 and 6 you can scale the available measuring range (15 or 30 m) of
an OTT CBS to a smaller range. Where the whole measuring range is not required,
this has the advantage that a higher resolution for the 4 … 20 mA interface can
be achieved. Example: For 2 m water level change 16 mA measuring range is
available (DIP switches 5 + 6 = OFF).