Side of building
Side of building
Side of building
Side of building
Position away from walls
Position as vertically as possible
WARNING
This monitor has been tested and certified safe for use
in Class 1, Division 2, Groups C & D T3 hazardous locations. Changes
or modifications to the unit must only be performed by an authorized
technician. For outdoor use only. Explosion Hazard - Batteries must
only be changed in an area free of ignitable concentrations.
Do not open when an explosive atmosphere is present. Potential
electrostatic charging hazard - wipe only with a damp cloth.
Battery Replacement - Use ONLY the following Otodata replaceable
battery packs. 3-ER26500M/W, 10.8Vdc/9Ah or G0249-LF, 7.2Vdc/9Ah.
Battery replacement is to be done ONLY when an explosive atmosphere
is not present. This device provides non-incendive circuits to cable sensor
assembly Part Number: HE-LEAD-CIRC-6.
Do not
pressure wash
IMPORTANT
It is critical in all installations to ensure monitors’
antenna is positioned vertically. This will:
❶
achieve optimal signal strength, ensuring that
you receive the data in a timely manner and
❷
prolong the battery life of the monitor, saving
time and money in the long run.
NOTES
❶
For underground tank install on pit
cover. Do not install inside pit. For metal cover:
magnet mount on cover. For plastic cover: use
screws to fasten on cover.
❷
Make sure gauge
is screwed on and fastened properly. Ensure that
the gauge is clean and free of dirt and debris.
❸
Underground tanks may require right angle (90°)
leads.
VERTICAL TANK MODEL
a) Use the supplied cable tie to secure the unit
to the collar or mag-mount it on the shoulder
near the collar;
b) For optimal signal strength, please ensure the
antenna is positioned vertically;
c) Slide the remote sensor into the tank’s remote
ready dial until it snaps into place ensuring that
the dial is clean;
d) Ensure the lead wire snaps in properly;
e) Installation is now complete.
HORIZONTAL TANK MODEL
a) Mount the propane monitor magnetically
on top of the tank, ensuring that the remote
sensor lead wire can sufficiently reach the
tank’s gauge;
b) For optimal signal strength, please ensure
the antenna is positioned vertically;
c) Slide the remote sensor into the tank’s remote
ready dial until it snaps into place ensuring that
the dial is clean;
d) Use a cable tie to secure the lead to the
feed line and ensure that the cover can freely
swing open and closed without obstructing
or damaging the lead wire;
e) Installation is now complete.
Not optimal.
May
impact performance.
Optimal position.