background image

English

4

Specification

Dimensions and Weight

  Model  Height 

Width 

Depth 

Weight

  4278 

9.45

 (240 mm) 

7.87

 (200 mm) 

7.87

 (200 mm) 

14.33 lbs (6.5 kg) 

* per J518 SAE Code 61 standard

  Model Number 

Flow Range 

Pressure Range 

Inlet/Outlet Ports

 

4278 

2.5 - 100 gpm 

0 - 6000 psi 

1-5/16

 -12UN #16 SAE ORB

  

(10 - 400 lpm) 

(0 - 420 bar) 

Ambient temperature

41 - 104°F (5 to 40°C)

Fluid type

Hydraulic oil

Fluid temperature

32 - 250°F (0 to 120°C)

Flow

 

Accuracy: 

± 1% of full scale.

Pressure

 

Accuracy:  

± 1.6% of full scale.

Temperature Accuracy: 

± 2°F, 1°C. 

Construction materials

Case

Painted mild steel

Flow block

High tensile aluminum

Seals

FKM

Battery Details

PP3 9 volt Alkaline (IEC6LR61, ANSI/NEDA 1604A)

 

Fluid type

 

  Temp °C 

ISO15 

ISO22 

ISO32 

ISO37 

ISO46 

ISO68

 

 

85.9 

165.6 

309.3 

449.9 

527.6 

894.3

 

10 

49.0 

87.0 

150.8 

204.7 

244.9 

393.3

 

20 

30.4 

50.5 

82.2 

105.5 

127.9 

196.1

 

30 

20.1 

31.6 

48.8 

59.8 

73.1 

107.7

 

40 

14.0 

21.0 

31.0 

36.6 

44.9 

63.9

 

50 

10.2 

14.7 

20.8 

23.9 

29.4 

40.5

 

60 

7.7 

10.7 

14.7 

16.5 

20.2 

27.2

 

70 

6.0 

8.1 

10.9 

12.0 

14.6 

19.2

 

80 

4.8 

6.4 

8.4 

9.1 

11.1 

14.3

 

90 

4.0 

5.2 

6.6 

7.2 

8.7 

11.1

 

100 

3.3 

4.3 

5.5 

6.0 

7.1 

8.9

Table showing kinematic viscosity (cSt) of different mineral oils at specific temperatures

ISO 15, 22, 32, 46 and 68 based on typical figures for the Esso Nuto range of 

HM oils. ISO 37 based on Shell Tellus HM oil.

Fluid viscosity

The performance of a turbine flow meter can be affected by the viscosity of the fluid measured. 

Our turbine flow meters are calibrated at between 18 and 26 cSt as standard (a mean viscosity 

of 21 cSt), which is the typical kinematic viscosity for a hydraulic fluid operating at 50 °C. The 

kinematic viscosity of all hydraulic fluids is related to the fluid temperature and the table below 

shows the affect of temperature on the kinematic viscosity of a range of typical grades of 

hydraulic oil.
The shaded area of the table shows the range of viscosities that can be measured by a flow 

meter with standard calibration with minimal effect on the accuracy (less that ± 1% FS).
Flow meters can be specially calibrated at a different viscosity to the standard or we can advise 

on the expected error when the flow meter is used at other viscosities, please contact sales 

for further information.

Reviews: