OT Systems FTD100-XXR3 Series Installation And Operation Manual Download Page 7

FTD100-XXR3 Series Installation & Operation Manual 

 

www.ot-systems.com

 

 

 

 

 

(3)  Installation 

3.1  General 

All  OT  Systems  products  are  thoroughly  inspected,  tested  and  securely  packaged  before 

delivery  to  ensure  a  stable,  intact  and  trouble-free  service.  Please  check  the  equipment  upon 

receipt for any visible damage which may have been caused during shipping. 

The  FTD100-XXR3SA  Series  standalone  units  (Fig.  3.1)  can  be  either  horizontally  or 

vertically wall-mounted, or mounted on any fixture. The Standalone unit works with an external 

power supply FT-PA/12V powered by local 110/220V power.   

The FTD100-XXR3 Series card modules are housed inside the FT-C18 rack-mount chassis 

(Fig. 3.2) with an included power supply unit. The whole chassis is powered by local 110/220V 

power.  FT-C18  is  a 

standard  19”  (483mm)  rack-mount  chassis  which  occupies  4  rack  units 

(177.8mm) in height. Each FT110DF card module occupies one slot and a total of 18 cards can 

be housed inside the chassis. 

 

3.2  Standalone unit installation 

a) 

Mount  the standalone unit onto a fixture, (either on the wall or on a flat surface) with four 

screws through the holes on the mounting frame to secure it in position.   

b) 

The provided power supply should also be mounted on the same fixture or in the proximity 

for  connection  of  the  supply  cables  to  the  unit,  provided  that  an  AC  power  supply  socket  is 

nearby for powering the adaptor. 

c) 

Connect  all  the  signal  inputs  and  outputs  at  the  back  of  the  unit  with  appropriate  cables: 

fiber optic cable for optical link, BNC cables for video outputs.   

d) 

Once the unit is powered up, check that the red POWER LED on the unit is lit. If not, check 

the power supply cable connections between the unit and the power supply socket. 

e) 

With all the signals available at the input and output ports, check the status of LEDs located 

on the unit. With correct status of each LED, installation is now completed [for LEDs status, see 

Operational Guides

 

on this manual’s section 

(5)

]. 

 

 

Fig. 3.1 

Standalone unit

 

Fig. 3.2 

FT-C18 chassis

 

Summary of Contents for FTD100-XXR3 Series

Page 1: ...All Digital Fiber Optic Manufacturing Specialists Installation and Operation Manual FTD100 XXR3 Series 8 bit Digital Series Triple Independent Video Fiber Optic Receiver OT Systems Ltd 2009 Rev 1 1...

Page 2: ...0 SSR3 FTD100 SSR3L Multi Mode Receiver FTD100 SMR3 Compatible with the following TRANSMITTERS FTD100Micro Series FTD100M Series FTD100 Series Single Mode FTD100Micro SST FTD100Micro SSTL Multi Mode F...

Page 3: ...IEW 4 2 1 Introduction 4 2 2 Models selection table 5 3 INSTALLATION 6 3 1 General 6 3 2 Standalone unit installation 6 3 3 Card module installation 7 4 CABLE CONNECTIONS SETUP PROCEDURES 7 4 1 System...

Page 4: ...to Class I invisible optical radiation is possible when the internal fiber optic connector is disconnected while the unit is powered up Caution Any access to the controls adjustments or performing ope...

Page 5: ...l video transmission scheme is implemented which supports video in NTSC PAL and SECAM formats For single mode transmission we also offer specifically designed products for long haul transmissions up t...

Page 6: ...deo Receiver Standalone Unit Multi Mode FTD100 SMR3SA Triple Independendent Multi mode Video Receiver Standalone Unit Card Modules Single Mode FTD100 SSR3 Triple Independendent Single mode Video Recei...

Page 7: ...ne slot and a total of 18 cards can be housed inside the chassis 3 2 Standalone unit installation a Mount the standalone unit onto a fixture either on the wall or on a flat surface with four screws th...

Page 8: ...d Once the chassis is powered up check that the red POWER LED on the front and back panels of the card modules are lit If not check the power supply cable connections between the chassis and the powe...

Page 9: ...ms FTD100 XXR3 Series Receiver Fig 4 1 Micro units to Card Module connection diagram FTD100 XXR3SA Series Receiver Fig 4 2 Micro units to Standalone unit connection diagram TRANSMITTERS CAN BE FTD100M...

Page 10: ...andalone unit earth ground terminal location 5 Operational Guides LED Indicators Indicator Color Description CH1 CH2 CH3 PWR Red Lit when power is supplied to the Receiver OL Yellow Lit when optical s...

Page 11: ...t Impedance 75 Ohm Input Output Level 1 0 Vp p typical Differential Gain 1 typical Differential Phase 1 o typical SNR 60dB POWER Power consumption 12VDC 6W Power Supply Standalone unit FT PA12V DC Ada...

Page 12: ...e refer to the OT Systems Products Warranty Statement for details Access to the statement is available in our company website at www ot systems com 9 Contact Information OT Systems Ltd Hong Kong Unit...